Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Results in Physics

Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams

Lin Li, Junjian Tang, Binbin Zhao, Yueyang Zhai

Published Jul 13, 2023• 6 citations
Publisher

Abstract

In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.

DOI
10.1016/j.rinp.2023.106728

Related papers

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•123 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•22 citations

A high-sensitivity single-light-dource triaxial atomic magnetometer with double-cell and orthogonally pumped structure

Zinan Wu, Jialong Zhang, Mengyang He +7 more

We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.

Optics Express•Feb 24, 2023•13 citations

A High-Sensitivity Single-Beam Triaxial Atomic Magnetometer Based on Optical Fiber Transmission

Zinan Wu, Jialong Zhang, Mengyang He +6 more

The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.

IEEE Conference on Telecommunications, Optics and Computer Science (TOCS)•Dec 11, 2022•0 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•2 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•14 citations
In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.
The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.