Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Conference on Telecommunications, Optics and Computer Science (TOCS)

A High-Sensitivity Single-Beam Triaxial Atomic Magnetometer Based on Optical Fiber Transmission

Zinan Wu, Jialong Zhang, Mengyang He, Bokang Ren, Zilong Wang, Zhonghua Ou, Huimin Yue, Xiaojun Zhou, Yong Liu

Published Dec 11, 2022• 0 citations
Publisher

Abstract

The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.

DOI
10.1109/tocs56154.2022.10015935

Related papers

A high-sensitivity single-light-dource triaxial atomic magnetometer with double-cell and orthogonally pumped structure

Zinan Wu, Jialong Zhang, Mengyang He +7 more

We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.

Optics Express•Mar 7, 2023•14 citations

Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams

Lin Li, Junjian Tang, Binbin Zhao +1 more

In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.

Results in Physics•Jul 13, 2023•7 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Nov 2, 2022•23 citations

Three-axis atomic magnetometer based on spin precession modulation

Hao Huang, Hai Feng Dong, Xiaofei Hu +2 more

We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.

Applied Physics Letters•Nov 2, 2015•65 citations

基于交叉偏置磁场的单光束三轴原子磁力仪

吴梓楠 Wu Zinan, 张佳龙 Zhang Jialong, 何孟阳 He Mengyang +6 more

We report a single-beam triaxial atomic magnetometer based on cross bias magnetic field. Based on Bloch equation, the theory of single-beam scheme to achieve triaxial magnetic field detection is studied. To achieve triaxial magnetic field detection, the method of using cross bias magnetic field to rotate the atomic spin polarization direction is proposed and experimentally verified. By using only one single modulation magnetic field, it is possible to suppress low frequency noise and avoid the problem of magnetic field cross-talk. The experimental results show that the system response bandwidth to the magnetic field along X-axis is 90 Hz and the system sensitivity is 21 fT/(Hz1/2) under the zero-field condition. The system response bandwidth to the magnetic field along Y-axis is 130 Hz and the system sensitivity is 26 fT/(Hz1/2) when a bias magnetic field of 34 nT is applied in the Z-axis. The system response bandwidth to the magnetic field along Z-axis is 128 Hz and the system sensitivity is 29 fT/(Hz1/2) when a bias magnetic field of 38 nT is applied in the Y-axis. The proposed triaxial atomic magnetometer has the advantages of small size, simple structure and low fabrication cost, and is expected to be used in the biomedical and other fields.

Laser & Optoelectronics Progress•Jan 1, 2024•0 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•3 citations
The SERF atomic magnetometer is nowadays the most sensitive equipment for magnetic field measurement. As used in triaxial magnetic field measurements, however, the weak interaction of the polarized atoms with the magnetic field in the pump light direction results in low sensitivity in that direction. To solve this issue, a single-beam orthogonal pumping triaxial atomic magnetometer based on a double-cell structure is demonstrated. In this paper, we use a beam-splitter to split the pumping light beam equally, so that the proposed triaxial atomic magnetometer can respond to magnetic fields in all three axes simultaneously, and with no sacrifice in sensitivity. The experiments have shown that the magnetometer has a sensitivity of 46fT/Hz1/2on the x-axis, 32fT/Hz1/2on the y-axis, and 40fT/Hz1/2on the z-axis. This magnetometer has great potential for applications where the three components of the magnetic field need to be measured.
We first report a single-light-source orthogonally pumped triaxial atomic magnetometer with a double-cell structure. By using a beam splitter to equally allocate the pump beam, the proposed triaxial atomic magnetometer is responsive to magnetic fields in all three directions, and without sacrificing system sensitivity. The experimental results indicate that, the magnetometer achieves a sensitivity of 22 fT/Hz 1/2 in x-direction with a 3-dB bandwidth of 22 Hz, a sensitivity of 23 fT/Hz 1/2 in y-direction with a 3-dB bandwidth of 23 Hz, and a sensitivity of 21 fT/Hz 1/2 in z-direction with a 3-dB bandwidth of 25 Hz. This magnetometer is useful for the applications that require the measurements of the three components of the magnetic field.
In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.
We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.
We report a single-beam triaxial atomic magnetometer based on cross bias magnetic field. Based on Bloch equation, the theory of single-beam scheme to achieve triaxial magnetic field detection is studied. To achieve triaxial magnetic field detection, the method of using cross bias magnetic field to rotate the atomic spin polarization direction is proposed and experimentally verified. By using only one single modulation magnetic field, it is possible to suppress low frequency noise and avoid the problem of magnetic field cross-talk. The experimental results show that the system response bandwidth to the magnetic field along X-axis is 90 Hz and the system sensitivity is 21 fT/(Hz1/2) under the zero-field condition. The system response bandwidth to the magnetic field along Y-axis is 130 Hz and the system sensitivity is 26 fT/(Hz1/2) when a bias magnetic field of 34 nT is applied in the Z-axis. The system response bandwidth to the magnetic field along Z-axis is 128 Hz and the system sensitivity is 29 fT/(Hz1/2) when a bias magnetic field of 38 nT is applied in the Y-axis. The proposed triaxial atomic magnetometer has the advantages of small size, simple structure and low fabrication cost, and is expected to be used in the biomedical and other fields.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.