Magneto-optical trapping in a near-suface borehole
Jamie Vovrosh, Katie Wilkinson, Sam Hedges, Kieran McGovern, Farzad Hayati, Christopher Carson, Adam Selyem, Jonathan Winch, Ben Stray, Luuk Earl, Maxwell Hamerow, Georgia Wilson, Adam Seedat, Sanaz Roshanmanesh, Kai Bongs, Michael Holynski
Borehole gravity sensing can be used in a number of applications to measure features around a well, including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors, based on atom interferometry, have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60 ± 0.1) mm at its widest point and a length of (890 ± 5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate how in-borehole gravity surveys are performed. During the survey, the system generated, on average, clouds of (3.0 ± 0.1) × 105 87Rb atoms with the standard deviation in atom number across the survey observed to be as low as 8.9 × 104.
Borehole gravity sensing can be used in a number of applications to measure features around a well, including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors, based on atom interferometry, have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60 ± 0.1) mm at its widest point and a length of (890 ± 5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate how in-borehole gravity surveys are performed. During the survey, the system generated, on average, clouds of (3.0 ± 0.1) × 105 87Rb atoms with the standard deviation in atom number across the survey observed to be as low as 8.9 × 104.
Borehole gravity sensing can be used in a number of applications to measure features around a well including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors based on atom interferometry have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60±0.1) mm at its widest point and a length of (890±5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate an in-borehole gravity surveys are performed. During the survey the system generated on average clouds of (3.0 ±0.1)×10587Rb atoms with the standard deviation in atom number across the survey observed to be as low as 9×104.
The extraordinary performance offered by cold atom-based clocks and sensors has the opportunity to profoundly affect a range of applications, for example in gravity surveys, enabling long term monitoring applications through low drift measurements. While ground-based devices are already starting to enter the commercial market, significant improvements in robustness and reductions to size, weight, and power are required for such devices to be deployed by Unstaffed Aerial Vehicle systems (UAV). In this article, we realise the first step towards the deployment of cold atom based clocks and sensors on UAV’s by demonstrating an UAV portable magneto-optical trap system, the core package of cold atom based systems. This system is able to generate clouds of 2.1±0.2×107 atoms, in a package of 370 mm × 350 mm × 100 mm, weighing 6.56 kg, consuming 80 W of power.
The high precision and scalable technology offered by atom interferometry has the opportunity to profoundly affect gravity surveys, enabling the detection of features of either smaller size or greater depth. While such systems are already starting to enter into the commercial market, significant reductions are required in order to reach the size, weight and power of conventional devices. In this article, the potential for atom interferometry based gravimetry is assessed, suggesting that the key opportunity resides within the development of gravity gradiometry sensors to enable drastic improvements in measurement time. To push forward in realizing more compact systems, techniques have been pursued to realize a highly portable magneto-optical trap system, which represents the core package of an atom interferometry system. This can create clouds of 10 7 atoms within a system package of 20 l and 10 kg, consuming 80 W of power. This article is part of the themed issue ‘Quantum technology for the 21st century’.
In the past century, the development of gravimeters with low uncertainty and long-term stability has led to new fields of research in geodesy and geoscience. Decreasing the instrumental measurement uncertainty further will enable observations of previously inaccessible phenomena, for instance, mass transport in hydrology and volcanology. During the last decades, quantum sensors based on the interference of cold atoms have been developed. Using a cold atomic gas as test mass, the accuracy of these sensors is not limited by mechanical properties but by effects caused by the thermal expansion of the atomic ensemble. The application of ultra-cold atomic ensembles with lower expansion rates in atom interferometer gravimeters is projected to reduce the leading order uncertainties by more than an order of magnitude. At the same time, atom chip technology makes it possible to prepare ultra-cold atomic ensembles at a high repetition rate and to miniaturise the sensor size. These advancements promise the realisation of an absolute gravimeter with unprecedented accuracy. This thesis describes the design considerations and the assembly of the transportable Quantum Gravimeter (QG-1) based on light-pulse atom interferometry of Bose-Einstein condensates (BEC) prepared on an atom chip. It is estimated, that the two leading order uncertainties of systematic biases governing the instrumental measurement uncertainty of current generation cold atom gravimeters are reduced to less than 1 nm/s² in the QG-1 apparatus. The established design of an atom-chip-based BEC source pioneered in the Quantus collaboration is modified to meet the requirements of QG-1. A free optical aperture of 18 mm for the interferometry laser beam is realised by changing the orientation of the atom-chip-based BEC source. Therefore, a new layout of the mesoscopic wire structure of the atom chip is required. The design described in this thesis enables atom interferometry with a free falling test mass with a baseline of 330 mm. The retro-reflection mirror is placed inside the vacuum chamber to eliminate optical elements in the atom interferometer beam path. It is mounted on a custom designed tip/tilt-stage with compact size and a large dynamic range of up to a hundredfold of the Earth's rotation rate for characterisation. Furthermore, a compact, robust and transportable fibre based laser system with modular electronics and a computer control system are set up. The key result of this thesis is the reliable operation of the ultra-cold atomic source on the atom chip. After optimisation of the trap loading procedure for a high atom number and low excitation of oscillations, it was shown that the necessary design change of the atom chip allows for efficient operation. The compressed magnetic trap has a geometrically averaged trap frequency of 2π · 256 Hz and the trapped ensemble has a lifetime of 3.2 s. The evaporative cooling procedure starts with 3.3 · 10⁷ atoms at a temperature of 166 μK. Within 1.3 s, or 2.3 s for the complete sequence, 3000 atoms are prepared at a temperature of 160 nK close to the critical temperature for Bose-Einstein condensation.
Gravity sensing is a valuable technique used for several applications, including fundamental physics, civil engineering, metrology, geology, and resource exploration. While classical gravimeters have proven useful, they face limitations, such as mechanical wear on the test masses, resulting in drift, and limited measurement speeds, hindering their use for long-term monitoring, as well as the need to average out microseismic vibrations, limiting their speed of data acquisition. Emerging sensors based on atom interferometry for gravity measurements could offer promising solutions to these limitations, and are currently advancing towards portable devices for real-world applications. This article provides a brief state-of-the-art review of portable atom interferometry-based quantum sensors and provides a perspective on routes towards improved sensors.
As a powerful tool in scientific research and industrial technologies, the cold atom absolute gravity sensor (CAGS) based on cold atom interferometry has been proven to be the most promising new generation high-precision absolute gravity sensor. However, large size, heavy weight, and high-power consumption are still the main restriction factors of CAGS being applied for practical applications on mobile platforms. Combined with cold atom chips, it is possible to drastically reduce the complexity, weight, and size of CAGS. In this review, we started from the basic theory of atom chips to chart a clear development path to related technologies. Several related technologies including micro-magnetic traps, micro magneto-optical traps, material selection, fabrication, and packaging methods have been discussed. This review gives an overview of the current developments in a variety of cold atom chips, and some actual CAGS systems based on atom chips are also discussed. We summarize by listing some of the challenges and possible directions for further development in this area.