Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Atoms

Demonstration of a Compact Magneto-Optical Trap on an Unstaffed Aerial Vehicle

Luuk Earl, Jamie Vovrosh, Michael Wright, Daniel Roberts, Jonathan Winch, Marisa Perea-Ortiz, Andrew Lamb, Farzad Hayati, Paul F. Griffin, Nicole Metje, Kai Bongs, Michael Holynski

Published Mar 17, 2022• 17 citations
Publisher

Abstract

The extraordinary performance offered by cold atom-based clocks and sensors has the opportunity to profoundly affect a range of applications, for example in gravity surveys, enabling long term monitoring applications through low drift measurements. While ground-based devices are already starting to enter the commercial market, significant improvements in robustness and reductions to size, weight, and power are required for such devices to be deployed by Unstaffed Aerial Vehicle systems (UAV). In this article, we realise the first step towards the deployment of cold atom based clocks and sensors on UAV’s by demonstrating an UAV portable magneto-optical trap system, the core package of cold atom based systems. This system is able to generate clouds of 2.1±0.2×107 atoms, in a package of 370 mm × 350 mm × 100 mm, weighing 6.56 kg, consuming 80 W of power.

DOI
10.3390/atoms10010032

Related papers

Taking off with quantum sensors on unstaffed aerial vehicles

Jamie Vovrosh, Farzad Hayati

The extraordinary performance of quantum sensors based on cold atoms will enhance our understanding of the world around us. While ground-based devices are currently in use, their deployment by Unstaffed Aerial Vehicles (UAV's) requires significant reductions in size, weight, and power. This work has realised the first step towards the deployment of cold atom-based sensors on UAV’s.

TheScienceBreaker•Oct 12, 2023•0 citations

Magneto-optical trapping in a near-suface borehole

Jamie Vovrosh, Katie Wilkinson, Sam Hedges +13 more

Borehole gravity sensing can be used in a number of applications to measure features around a well, including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors, based on atom interferometry, have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60 ± 0.1) mm at its widest point and a length of (890 ± 5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate how in-borehole gravity surveys are performed. During the survey, the system generated, on average, clouds of (3.0 ± 0.1) × 105 87Rb atoms with the standard deviation in atom number across the survey observed to be as low as 8.9 × 104.

PLoS ONE•Jul 11, 2023•6 citations

A portable magneto-optical trap with prospects for atom interferometry in civil engineering

Andrew Hinton, Marisa Perea-Ortiz, Jonathan Winch +21 more

The high precision and scalable technology offered by atom interferometry has the opportunity to profoundly affect gravity surveys, enabling the detection of features of either smaller size or greater depth. While such systems are already starting to enter into the commercial market, significant reductions are required in order to reach the size, weight and power of conventional devices. In this article, the potential for atom interferometry based gravimetry is assessed, suggesting that the key opportunity resides within the development of gravity gradiometry sensors to enable drastic improvements in measurement time. To push forward in realizing more compact systems, techniques have been pursued to realize a highly portable magneto-optical trap system, which represents the core package of an atom interferometry system. This can create clouds of 10 7 atoms within a system package of 20 l and 10 kg, consuming 80 W of power. This article is part of the themed issue ‘Quantum technology for the 21st century’.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Jun 26, 2017•63 citations

Magneto-optical trapping in a near-surface borehole

Jamie Vovrosh, Wilkinson, Katie, Hedges, Sam +13 more

Borehole gravity sensing can be used in a number of applications to measure features around a well including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors based on atom interferometry have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of ($60\pm0.1$) mm at its widest point and a length of ($890\pm5$) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate an in-borehole gravity surveys are performed. During the survey the system generated on average clouds of (3.0 $\pm 0.1) \times 10^{5}$ $^{87}$Rb atoms with the standard deviation in atom number across the survey observed to be as low as $9 \times 10^{4}$.

arXiv:2211.11415•Nov 21, 2022•0 citations

Field deployable atomics package for an optical lattice clock

Y. B. Kale, Alok K. Singh, Markus Gellesch +5 more

Abstract An atomics package is the heart of any atom based quantum sensing device. Here we report on the realisation of a field deployable atomics package for alkaline earth atoms, e.g. Sr or Yb. In terms of size (∼121 L), weight (<75 kg) and power (∼320 W), it is the smallest package to date which is designed to load Sr atoms into an optical lattice. It consists of an ultra-high vacuum assembly (<4 L), lasers, magnetic field coils & optics required for cooling & trapping as well as a module for imaging & detection. The package can routinely produce ultra cold and dense samples of 1.6 × 105 88Sr atoms trapped in a 1D optical lattice in less than a second. Its robustness has been demonstrated by conducting two transportation campaigns within out-of-the-lab environments. This advancement will have impact not only on transportable optical clock development but also will influence the wider areas of quantum science and technologies, particularly requiring field deployable cold atom based quantum sensors.

Quantum Science and Technology•Jun 22, 2022•17 citations

Towards a compact, optically interrogated, cold-atom microwave clock

Rachel Elvin, Michael W. Wright, Ben Lewis +6 more

Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ $\perp $ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ $5{\times}{10}^{-11}/\sqrt{\tau }$ with a projected quantum projection noise limit at the 10 − 13 / τ ${10}^{-13}/\sqrt{\tau }$ level.

Advanced Optical Technologies•Sep 7, 2019•7 citations
The extraordinary performance offered by cold atom-based clocks and sensors has the opportunity to profoundly affect a range of applications, for example in gravity surveys, enabling long term monitoring applications through low drift measurements. While ground-based devices are already starting to enter the commercial market, significant improvements in robustness and reductions to size, weight, and power are required for such devices to be deployed by Unstaffed Aerial Vehicle systems (UAV). In this article, we realise the first step towards the deployment of cold atom based clocks and sensors on UAV’s by demonstrating an UAV portable magneto-optical trap system, the core package of cold atom based systems. This system is able to generate clouds of 2.1±0.2×107 atoms, in a package of 370 mm × 350 mm × 100 mm, weighing 6.56 kg, consuming 80 W of power.
Borehole gravity sensing can be used in a number of applications to measure features around a well, including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors, based on atom interferometry, have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60 ± 0.1) mm at its widest point and a length of (890 ± 5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate how in-borehole gravity surveys are performed. During the survey, the system generated, on average, clouds of (3.0 ± 0.1) × 105 87Rb atoms with the standard deviation in atom number across the survey observed to be as low as 8.9 × 104.
The high precision and scalable technology offered by atom interferometry has the opportunity to profoundly affect gravity surveys, enabling the detection of features of either smaller size or greater depth. While such systems are already starting to enter into the commercial market, significant reductions are required in order to reach the size, weight and power of conventional devices. In this article, the potential for atom interferometry based gravimetry is assessed, suggesting that the key opportunity resides within the development of gravity gradiometry sensors to enable drastic improvements in measurement time. To push forward in realizing more compact systems, techniques have been pursued to realize a highly portable magneto-optical trap system, which represents the core package of an atom interferometry system. This can create clouds of 10 7 atoms within a system package of 20 l and 10 kg, consuming 80 W of power. This article is part of the themed issue ‘Quantum technology for the 21st century’.
Borehole gravity sensing can be used in a number of applications to measure features around a well including rock-type change mapping and determination of reservoir porosity. Quantum technology gravity sensors based on atom interferometry have the ability to offer increased survey speeds and reduced need for calibration. While surface sensors have been demonstrated in real world environments, significant improvements in robustness and reductions to radial size, weight, and power consumption are required for such devices to be deployed in boreholes. To realise the first step towards the deployment of cold atom-based sensors down boreholes, we demonstrate a borehole-deployable magneto-optical trap, the core package of many cold atom-based systems. The enclosure containing the magneto-optical trap itself had an outer radius of (60±0.160\pm0.160±0.1) mm at its widest point and a length of (890±5890\pm5890±5) mm. This system was used to generate atom clouds at 1 m intervals in a 14 cm wide, 50 m deep borehole, to simulate an in-borehole gravity surveys are performed. During the survey the system generated on average clouds of (3.0 ±0.1)×105\pm 0.1) \times 10^{5}±0.1)×105 87^{87}87Rb atoms with the standard deviation in atom number across the survey observed to be as low as 9×1049 \times 10^{4}9×104.
Abstract An atomics package is the heart of any atom based quantum sensing device. Here we report on the realisation of a field deployable atomics package for alkaline earth atoms, e.g. Sr or Yb. In terms of size (∼121 L), weight (<75 kg) and power (∼320 W), it is the smallest package to date which is designed to load Sr atoms into an optical lattice. It consists of an ultra-high vacuum assembly (<4 L), lasers, magnetic field coils & optics required for cooling & trapping as well as a module for imaging & detection. The package can routinely produce ultra cold and dense samples of 1.6 × 105 88Sr atoms trapped in a 1D optical lattice in less than a second. Its robustness has been demonstrated by conducting two transportation campaigns within out-of-the-lab environments. This advancement will have impact not only on transportable optical clock development but also will influence the wider areas of quantum science and technologies, particularly requiring field deployable cold atom based quantum sensors.
Abstract A compact platform for cold atoms opens a range of exciting possibilities for portable, robust and accessible quantum sensors. In this work, we report on the development of a cold-atom microwave clock in a small package. Our work utilises the grating magneto-optical trap and high-contrast coherent population trapping in the lin ⊥ $\perp $ lin polarisation scheme. We optically probe the atomic ground-state splitting of cold 87Rb atoms using a Ramsey-like sequence whilst the atoms are in free-fall. We have measured a short-term fractional frequency stability of 5 × 10 − 11 / τ 5×10−11/τ5{\times}{10}^{-11}/\sqrt{\tau }5×10−11/τ​ with a projected quantum projection noise limit at the 10 − 13 / τ 10−13/τ{10}^{-13}/\sqrt{\tau }10−13/τ​ level.