Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1111.5890

A Miniature Cold-Atom Frequency Standard

Vishal Shah, Mark J. Mescher, Rick Stoner, Vladan Vuletić, Robert Lutwak

Published Nov 25, 2011• 2 citations
arXivHTMLPDF

Abstract

Atomic sensors employing cold-atom technology enable unprecedented accuracy and resolution for next generation atomic clocks, magnetometers, gravimeters, and gyroscopes. To date, however, the size and complexity of cold atom systems have prevented their deployment in practical applications outside of large research laboratories. Here we demonstrate a low power, palm-top, and fully integrated cold atom system that functions as an atomic clock with a stability of 2 parts in 10^11 at 1s. This work demonstrates the feasibility of developing compact, robust, and portable devices based on laser cooled atoms.

DOI
10.48550/arxiv.1111.5890

Related papers

Micro-fabricated components for cold atom sensors

J. P. McGilligan, Kevin Francis Gallacher, Paul F. Griffin +3 more

Laser cooled atoms have proven transformative for precision metrology, playing a pivotal role in state-of-the-art clocks and interferometers and having the potential to provide a step-change in our modern technological capabilities. To successfully explore their full potential, laser cooling platforms must be translated from the laboratory environment and into portable, compact quantum sensors for deployment in practical applications. This transition requires the amalgamation of a wide range of components and expertise if an unambiguously chip-scale cold atom sensor is to be realized. We present recent developments in cold-atom sensor miniaturization, focusing on key components that enable laser cooling on the chip-scale. The design, fabrication, and impact of the components on sensor scalability and performance will be discussed with an outlook to the next generation of chip-scale cold atom devices.

arXiv:2208.00680•Review of Scientific Instruments•Sep 1, 2022•56 citations

A compact and low-power cold atom clock

Vishal Shah, Robert Lutwak, Richard E. Stoner +1 more

We report on our progress towards the development of a miniature cold atom frequency standard (MCAFS). The ultimate program objective is a chip-scale atomic clock (CSAC) with performance comparable to a bench top Cesium beam primary standard. We have addressed many of the critical hurdles of this project and demonstrated its feasibility with a compact and fully integrated prototype.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2012•3 citations

Miniature, compact laser system for ultracold atom sensors

J. M. Pino, Ben Luey, Sarah Bickman +1 more

As ultracold atom sensors begin to see their way to the field, there is a growing need for small, accurate, and robust laser systems to cool and manipulate atoms for sensing applications such as magnetometers, gravimeters, atomic clocks and inertial sensing. In this paper we present a frequency-agile, butterfly packaged laser source, absolutely referenced to an atomic transition. We also present the entire laser system, including a fiber-coupled optical amplifier and liquid crystal shutters, replacing a laboratory table’s worth of optics with a system the size of a paperback novel.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 31, 2013•2 citations

A new generation of high-performance operational quantum sensors (Conference Presentation)

Jean Lautier‐Gaud, Bruno Desruelle, Vincent Ménoret +3 more

After 30 years of academic research in cold atom sciences, intensive developments are being conducted to improve the compactness and the reliability of experimental set-ups in order to transfer such devices from laboratory-based research to an operational utilization outside of the laboratory. We will present the long-lasting developments that we have been carrying to provide the first industrial cold-atom absolute gravimeter and the first industrial cold-atom atomic clock. We will present in detail the principles of operation and the main features of our instruments. Their performances in terms of sensitivity, stability and accuracy and the latest results they achieved will be reviewed. We will then discuss their use to support other research activities. One of the key technology elements of such instruments that need to be addressed is the laser system used to cool down and manipulate the atoms. A specific focus on our latest developments in this area in terms of performances will be proposed.

•Aug 3, 2016•0 citations

Progress on a Miniature Cold-Atom Frequency Standard

David R. Scherer, Robert Lutwak, Mark J. Mescher +8 more

Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.

arXiv:1411.5006•Nov 18, 2014•7 citations

Utilising diffractive optics towards a compact, cold atom clock

J. P. McGilligan, Rachel Elvin, Paul F. Griffin +2 more

Laser cooled atomic samples have resulted in profound advances in precision metrology [1], however the technology is typically complex and bulky. In recent publications we described a micro-fabricated optical element, that greatly facilitates miniaturisation of ultra-cold atom technology [2], [3], [4], [5]. Portable devices should be feasible with accuracy vastly exceeding that of equivalent room-temperature technology, with a minimal footprint. These laser cooled samples are ideal for atomic clocks. Here we will discuss the implementation of our micro-fabricated diffractive optics towards building a robust, compact cold atom clock.

European Frequency and Time Forum•Apr 1, 2016•1 citation
Atomic sensors employing cold-atom technology enable unprecedented accuracy and resolution for next generation atomic clocks, magnetometers, gravimeters, and gyroscopes. To date, however, the size and complexity of cold atom systems have prevented their deployment in practical applications outside of large research laboratories. Here we demonstrate a low power, palm-top, and fully integrated cold atom system that functions as an atomic clock with a stability of 2 parts in 10^11 at 1s. This work demonstrates the feasibility of developing compact, robust, and portable devices based on laser cooled atoms.
Laser cooled atoms have proven transformative for precision metrology, playing a pivotal role in state-of-the-art clocks and interferometers and having the potential to provide a step-change in our modern technological capabilities. To successfully explore their full potential, laser cooling platforms must be translated from the laboratory environment and into portable, compact quantum sensors for deployment in practical applications. This transition requires the amalgamation of a wide range of components and expertise if an unambiguously chip-scale cold atom sensor is to be realized. We present recent developments in cold-atom sensor miniaturization, focusing on key components that enable laser cooling on the chip-scale. The design, fabrication, and impact of the components on sensor scalability and performance will be discussed with an outlook to the next generation of chip-scale cold atom devices.
As ultracold atom sensors begin to see their way to the field, there is a growing need for small, accurate, and robust laser systems to cool and manipulate atoms for sensing applications such as magnetometers, gravimeters, atomic clocks and inertial sensing. In this paper we present a frequency-agile, butterfly packaged laser source, absolutely referenced to an atomic transition. We also present the entire laser system, including a fiber-coupled optical amplifier and liquid crystal shutters, replacing a laboratory table’s worth of optics with a system the size of a paperback novel.
After 30 years of academic research in cold atom sciences, intensive developments are being conducted to improve the compactness and the reliability of experimental set-ups in order to transfer such devices from laboratory-based research to an operational utilization outside of the laboratory. We will present the long-lasting developments that we have been carrying to provide the first industrial cold-atom absolute gravimeter and the first industrial cold-atom atomic clock. We will present in detail the principles of operation and the main features of our instruments. Their performances in terms of sensitivity, stability and accuracy and the latest results they achieved will be reviewed. We will then discuss their use to support other research activities. One of the key technology elements of such instruments that need to be addressed is the laser system used to cool down and manipulate the atoms. A specific focus on our latest developments in this area in terms of performances will be proposed.
Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of 16 cm3, power consumption of 120 mW, and instability (Allan Deviation) of σ(τ = 1 sec) < 2e-10. In order to reduce the temperature sensitivity of next-generation CSACs for timing applications, the interaction of atoms with the environment must be minimized, which can be accomplished in an architecture based on trapped, laser-cooled atoms. In this paper, we present results describing the development of a miniature cold-atom apparatus for operation as a frequency standard. Our architecture is based on laser-cooling a sample of neutral atoms in a Magneto-Optical Trap (MOT) using a conical retro-reflector in a miniature vacuum chamber. Trapping the atoms in vacuum and performing microwave interrogation in the dark reduces the temperature sensitivity compared to vapor-cell CSACs. We present details of the component development associated with the laser systems, opto-electronics, and vacuum package for miniature cold-atom technology. Finally, we conclude by characterizing the optimum alkali background pressure for such a cold-atom frequency standard.
Laser cooled atomic samples have resulted in profound advances in precision metrology [1], however the technology is typically complex and bulky. In recent publications we described a micro-fabricated optical element, that greatly facilitates miniaturisation of ultra-cold atom technology [2], [3], [4], [5]. Portable devices should be feasible with accuracy vastly exceeding that of equivalent room-temperature technology, with a minimal footprint. These laser cooled samples are ideal for atomic clocks. Here we will discuss the implementation of our micro-fabricated diffractive optics towards building a robust, compact cold atom clock.