Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE photonics journal

Precise Measurement of Polarization Variation Using Weak Measurement With Double Pointers

Lan E Luo, Yu He, Junfan Zhu, Liang Fang, Bo Liu, Zhiyou Zhang

Published May 31, 2023• 5 citations
Publisher

Abstract

In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of$\,10^{-7}rad$in the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.

DOI
10.1109/jphot.2023.3281586

Related papers

Determination of polarization states of light using the weak measurement with two pointers

Zhaoxue Li, Linguo Xie, Junfan Zhu +2 more

Measuring the polarization state of light has become a challenging study owing to its requirement to simultaneously extract the phase and amplitude parameters with high precision. Here, we present a weak measurement (WM) scheme with two pointers to determine a general polarization state. For the output spectrum from the WM regime, one pointer with the light frequency is used to measure the phase parameter while the other with the post-selected probability is to measure the amplitude. The optimized regime permits the simultaneous measurements of two parameters since the shift results of both two pointers are read in the same working regions. The simulated results show high sensitivity for both two parameters, and high precision that can be comparable with that by other existing schemes. Our scheme can be applied to measure other complex physical effects, providing a method for future ultra-sensitive sensing and metrology.

Applied Physics Express•Sep 3, 2021•3 citations

Simultaneously precise estimations of phase and amplitude variations based on weak-value amplification

Lan E Luo, Linguo Xie, Jiangdong Qiu +6 more

In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.

Applied Physics Letters•Mar 18, 2019•25 citations

Weak measurement with the peak-contrast-ratio pointer

Junfan Zhu, Zhaoxue Li, Yurong Liu +4 more

Weak measurement as a nonperturbative theory has been shown to be powerful in the fundamentals of quantum mechanics and high-precision metrology, in which the pointer is of great importance to parameter estimation and experimental design. In this work, we find that under the conditions of weak coupling and Gaussian meter, the probability distribution after the postselection follows a bimodal function and the peak contrast ratio (PCR) can be applied as a special pointer, which is different from the shift of mean value. To obtain the PCR, only two values corresponding to the two peaks in the distribution function are required. We theoretically present the relation of the PCR and parameters to be estimated, and then demonstrate it in an experiment. Weak measurement with the PCR pointer has the advantages of reducing the requirements of the apparatus and suppressing noise, which also provides a heuristic approach for studying weak measurement when the weak value is very large.

Physical Review A•Mar 16, 2021•19 citations

Partial-coherence weak measurement of polarization qubits with a temporal pointer: theory and experiment

Shane P. Gervais, Lambert Giner

Weak measurement has proven useful for metrology, for probing quantum paradoxes, and for the direct measurement of quantum states. Weak measurements of polarization qubits with temporal pointers provide a direct route to weak-value characterization, including in regimes where the pointer is only partially coherent. We derive a closed-form expression for the post-selected temporal shift that interpolates between the incoherent and coherent (ideal) weak-measurement limits through a single parameter $ν$, the pointer visibility. The expression is experimentally tested for a range of polarization states spanning three trajectories corresponding to rotations about the principal axes of the Poincaré sphere. Two of the trajectories provide parameter-free benchmarks, with the real part of the weak value following $\cos^2θ$ and $1/2$. In contrast, the weak value along the third trajectory is sensitive to incoherence and is well described by the single-parameter partial-coherence model, from which a reduced pointer visibility is obtained. Time shifts are extracted from the smoothed derivative of the pulse leading edge with internal calibration, reaching few-picosecond precision on 10 ns optical pulses using commercial components. The same apparatus also gives qualitative access to the imaginary quadrature through the frequency centroid, showing that temporal weak measurements remain accessible and quantitative in partially coherent pulsed systems.

quant-pharXiv:2610.14954•Results in Optics•Oct 13, 2026•0 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations

Estimation of Kerr angle based on weak measurement with two pointers

Lan E Luo, Tong Li, Yinghang Jiang +3 more

In this paper, we propose a weak measurement method using two pointers to estimate the magneto-optical Kerr angle, which is robust to ellipticity. The double pointers are the amplified displacement shift and intensity of the post-selected light beam, which are the conventional information carried by the light beam and can be directly output by a detector (such as a charge-coupled device). We demonstrate that the product of the double pointers is only related to the phase variation between two basic vectors and independent of the amplitude errors. In the measurement process, when there is an amplitude change or additional amplitude noise between two eigenstates, the product of two pointers is very useful in extracting phase information and shielding amplitude noise. In addition, the product of two pointers has a good linear relationship with the phase variation and a larger dynamic measurement range. This method is applied to measure the magneto-optical Kerr angle of NiFe film. The Kerr angle can be directly obtained using the product of the light intensity and the amplified displacement shift. This scheme is of great significance for the measurement of the Kerr angle of magnetic films.

Optics Express•Apr 3, 2023•13 citations
In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of 10−7rad\,10^{-7}rad10−7radin the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.
Measuring the polarization state of light has become a challenging study owing to its requirement to simultaneously extract the phase and amplitude parameters with high precision. Here, we present a weak measurement (WM) scheme with two pointers to determine a general polarization state. For the output spectrum from the WM regime, one pointer with the light frequency is used to measure the phase parameter while the other with the post-selected probability is to measure the amplitude. The optimized regime permits the simultaneous measurements of two parameters since the shift results of both two pointers are read in the same working regions. The simulated results show high sensitivity for both two parameters, and high precision that can be comparable with that by other existing schemes. Our scheme can be applied to measure other complex physical effects, providing a method for future ultra-sensitive sensing and metrology.
In this paper, we theoretically and experimentally present a precision method to simultaneously estimate the phase and amplitude variations of light based on the weak-value amplification. We demonstrate that the imaginary and real components of the weak-value correspond to the amplification of the phase and amplitude variations, respectively. If both the phase and the amplitude are varied, the phase measurement using the imaginary weak-value is not influenced by the amplitude shift and the amplitude measurement using the real weak value is not influenced by the phase shift. Thus, the tiny changes of the phase and amplitude of light can be obtained simultaneously with different post-selections, and the measurement precision reaches ∼10−6 rad. These findings may be favorable for highly sensitive optical polarization-dependent effects, including optical activity and magneto-optic effects.
Weak measurement as a nonperturbative theory has been shown to be powerful in the fundamentals of quantum mechanics and high-precision metrology, in which the pointer is of great importance to parameter estimation and experimental design. In this work, we find that under the conditions of weak coupling and Gaussian meter, the probability distribution after the postselection follows a bimodal function and the peak contrast ratio (PCR) can be applied as a special pointer, which is different from the shift of mean value. To obtain the PCR, only two values corresponding to the two peaks in the distribution function are required. We theoretically present the relation of the PCR and parameters to be estimated, and then demonstrate it in an experiment. Weak measurement with the PCR pointer has the advantages of reducing the requirements of the apparatus and suppressing noise, which also provides a heuristic approach for studying weak measurement when the weak value is very large.
Weak measurement has proven useful for metrology, for probing quantum paradoxes, and for the direct measurement of quantum states. Weak measurements of polarization qubits with temporal pointers provide a direct route to weak-value characterization, including in regimes where the pointer is only partially coherent. We derive a closed-form expression for the post-selected temporal shift that interpolates between the incoherent and coherent (ideal) weak-measurement limits through a single parameter ννν, the pointer visibility. The expression is experimentally tested for a range of polarization states spanning three trajectories corresponding to rotations about the principal axes of the Poincaré sphere. Two of the trajectories provide parameter-free benchmarks, with the real part of the weak value following cos⁡2θ\cos^2θcos2θ and 1/21/21/2. In contrast, the weak value along the third trajectory is sensitive to incoherence and is well described by the single-parameter partial-coherence model, from which a reduced pointer visibility is obtained. Time shifts are extracted from the smoothed derivative of the pulse leading edge with internal calibration, reaching few-picosecond precision on 10 ns optical pulses using commercial components. The same apparatus also gives qualitative access to the imaginary quadrature through the frequency centroid, showing that temporal weak measurements remain accessible and quantitative in partially coherent pulsed systems.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
In this paper, we propose a weak measurement method using two pointers to estimate the magneto-optical Kerr angle, which is robust to ellipticity. The double pointers are the amplified displacement shift and intensity of the post-selected light beam, which are the conventional information carried by the light beam and can be directly output by a detector (such as a charge-coupled device). We demonstrate that the product of the double pointers is only related to the phase variation between two basic vectors and independent of the amplitude errors. In the measurement process, when there is an amplitude change or additional amplitude noise between two eigenstates, the product of two pointers is very useful in extracting phase information and shielding amplitude noise. In addition, the product of two pointers has a good linear relationship with the phase variation and a larger dynamic measurement range. This method is applied to measure the magneto-optical Kerr angle of NiFe film. The Kerr angle can be directly obtained using the product of the light intensity and the amplified displacement shift. This scheme is of great significance for the measurement of the Kerr angle of magnetic films.