Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2610.14954 · Results in Optics

Partial-coherence weak measurement of polarization qubits with a temporal pointer: theory and experiment

Shane P. Gervais, Lambert Giner

quant-phphysics.opticsSubmitted Oct 10, 2026• Announced Oct 13, 2026• 0 citations
arXivHTMLPDF

Abstract

Weak measurement has proven useful for metrology, for probing quantum paradoxes, and for the direct measurement of quantum states. Weak measurements of polarization qubits with temporal pointers provide a direct route to weak-value characterization, including in regimes where the pointer is only partially coherent. We derive a closed-form expression for the post-selected temporal shift that interpolates between the incoherent and coherent (ideal) weak-measurement limits through a single parameter $ν$, the pointer visibility. The expression is experimentally tested for a range of polarization states spanning three trajectories corresponding to rotations about the principal axes of the Poincaré sphere. Two of the trajectories provide parameter-free benchmarks, with the real part of the weak value following $\cos^2θ$ and $1/2$. In contrast, the weak value along the third trajectory is sensitive to incoherence and is well described by the single-parameter partial-coherence model, from which a reduced pointer visibility is obtained. Time shifts are extracted from the smoothed derivative of the pulse leading edge with internal calibration, reaching few-picosecond precision on 10 ns optical pulses using commercial components. The same apparatus also gives qualitative access to the imaginary quadrature through the frequency centroid, showing that temporal weak measurements remain accessible and quantitative in partially coherent pulsed systems.

AI Summary

The paper examines how partial temporal coherence modifies post-selected weak-measurement signals for polarization qubits. For an input $a|H\rangle+b|V\rangle$, a polarization-dependent delay $\tau$, and diagonal post-selection, it models the normalized temporal centroid as $\widetilde W=(|a|^2+\nu\operatorname{Re}(a\bar b))/(1+2\nu\operatorname{Re}(a\bar b))$, where $\nu$ describes pointer overlap/coherence at the imposed delay. This interpolates between the incoherent population response and the ideal coherent weak-value response. The experiment uses a commercial multimode 640-nm laser producing 10-ns pulses, a polarization interferometer with approximately 177-ps differential delay, and photodiode/oscilloscope detection. Three polarization trajectories test the model: two predict visibility-independent responses, $\cos^2\theta$ and $1/2$, while the third constrains $\nu$. Timing is extracted from the maximum of a smoothed leading-edge derivative, rather than directly from the temporal centroid, with horizontal/vertical reference calibration. Repeated measurements give few-picosecond timing reproducibility. The $\cos^2\theta$ trajectory has an RMS residual of approximately 0.04; the constant trajectory averages $0.50\pm0.01$. A single-parameter fit to the coherence-sensitive trajectory yields $\nu=0.09\pm0.05$. Fourier analysis of the recorded intensity traces also gives a qualitative angular dependence associated with the magnitude of the imaginary weak value, without a calibrated magnitude or recovered sign. Stated limitations include slow acquisition drifts, angle-calibration uncertainty excluded from per-point statistical errors, and the restriction of a single visibility parameter to a fixed delay. More coherent sources and phase-preserving spectral detection are proposed for approaching ideal weak-value readout and recovering the imaginary-quadrature sign.

Little sign of AI-generated textAI use disclosedIncrementalStrong assumptionsPossible errorOverclaims
During the preparation of this work the authors used Anthropic Claude for language editing, manuscript-structure review, and LaTeX formatting assistance.

Central claim may not hold: The claimed general centroid law omits independent complex overlap and overlap-moment information, so its validity and the visibility-independent trajectory predictions require additional pointer assumptions. The experiment measures a leading-edge derivative maximum rather than the theoretical intensity centroid, without establishing that these observables obey the same state-dependent shift law. The finite-coupling error estimate does not use the temporal scale controlling the measured leading-edge feature and therefore does not establish negligible estimator bias. The Fourier-power centroid of a real detected intensity trace is either zero for the signed two-sided spectrum or an electrical spectral-shape statistic for a one-sided spectrum, with no demonstrated identification as the imaginary weak-value quadrature.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
23 pages, 8 figures

Related papers

Direct polarisation-state reconstruction with a temporal pointer: accessible states, resolution and optimal coupling

Shane P. Gervais, Lambert Giner

Weak measurements are used to amplify small signals, to address foundational questions, and to characterise quantum states without tomography. In direct state reconstruction each amplitude of the state vector is proportional to a single complex weak value, which for a temporal pointer is read from the mean arrival time and the mean frequency of the postselected pulse. Such an experiment requires three quantities to be fixed, the coupling, the angular resolution demanded of the reconstruction, and the set of states over which the method remains usable, and these are commonly set by the available apparatus rather than derived. We derive all three for a Gaussian temporal pointer and an arbitrary postselection state. The states that cannot be reconstructed form a spherical cap centred on the state orthogonal to the postselection, whose geodesic half-angle follows from the largest of three independent thresholds and involves no adjustable parameter. Two states are distinguishable only if they differ by more than a minimal step fixed by the coupling, by the number of incident photons and by the sensitivity of the weak value along the path followed. For an inversion at first order in the coupling the systematic and statistical errors are opposed and fix an optimal coupling that varies as the inverse sixth root of the number of incident photons, whereas an exact inversion at finite coupling removes the systematic error, the remaining bound being one on the two-centroid readout rather than on the inversion, since below an amplitude equal to a quarter of the coupling two states give the same pair of centroids while their profiles differ. These results allow a direct reconstruction experiment to be dimensioned before the apparatus is assembled.

quant-pharXiv:2610.16871•Oct 13, 2026•0 citations

Determination of polarization states of light using the weak measurement with two pointers

Zhaoxue Li, Linguo Xie, Junfan Zhu +2 more

Measuring the polarization state of light has become a challenging study owing to its requirement to simultaneously extract the phase and amplitude parameters with high precision. Here, we present a weak measurement (WM) scheme with two pointers to determine a general polarization state. For the output spectrum from the WM regime, one pointer with the light frequency is used to measure the phase parameter while the other with the post-selected probability is to measure the amplitude. The optimized regime permits the simultaneous measurements of two parameters since the shift results of both two pointers are read in the same working regions. The simulated results show high sensitivity for both two parameters, and high precision that can be comparable with that by other existing schemes. Our scheme can be applied to measure other complex physical effects, providing a method for future ultra-sensitive sensing and metrology.

Applied Physics Express•Sep 3, 2021•3 citations

Precise Measurement of Polarization Variation Using Weak Measurement With Double Pointers

Lan E Luo, Yu He, Junfan Zhu +3 more

In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of$\,10^{-7}rad$in the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.

IEEE photonics journal•May 31, 2023•5 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations

Practical weak measurement of multiparticle observables

Kevin J. Resch

Weak measurement is a potentially powerful tool for studying post-selected quantum systems. The original approach to weak measurement requires a different von Neumann interaction between the quantum system and measurement pointer for weak values of every different observable. When studying weak values of properties of more than one particle, which is necessary for studying entanglement, these interactions can range from difficult to impossible to implement experimentally. For example, the measurement of properties on a pair of optical photons requires a strong Kerr-like nonlinearity at the two-photon level. In a recent work, we described a new method for extracting weak values of operators that can be expressed as products of two local, single-particle operators by studying the correlations in experimentally feasible local, single-particle measurements. In the present work, that theoretical approach is generalized so that weak values of products of N local, single-particle operators can be extracted from the correlations in N single-particle measurements.

Journal of Optics B Quantum and Semiclassical Optics•Oct 5, 2004•17 citations

Realization of joint weak measurement in classical optics using optical beam shifts

Ritwik Dhara, Shyamal Guchhait, Sarkar, Meghna +3 more

Quantum weak measurements became extremely popular in classical optics to amplify small optical signals for fundamental interests and potential applications. Later, a more general extension, joint weak measurement has been proposed to extract weak value from a joint quantum measurement. However, the detection of joint weak value in the realm of classical optics remains less explored. Here, using the polarization-dependent longitudinal and transverse optical beam shift as a platform, we experimentally realize the quantum joint weak measurement in a classical optical setting. Polarization states are cleverly pre and post-selected, and different single and joint canonical position-momentum observables of the beam are experimentally extracted and subsequently analyzed for successful detection of complex joint weak value. We envision that this work will find usefulness for gaining fundamental insights on quantum measurements and to tackle analogous problems in optics.

arXiv:2412.07440•Dec 10, 2024•0 citations
Weak measurement has proven useful for metrology, for probing quantum paradoxes, and for the direct measurement of quantum states. Weak measurements of polarization qubits with temporal pointers provide a direct route to weak-value characterization, including in regimes where the pointer is only partially coherent. We derive a closed-form expression for the post-selected temporal shift that interpolates between the incoherent and coherent (ideal) weak-measurement limits through a single parameter ννν, the pointer visibility. The expression is experimentally tested for a range of polarization states spanning three trajectories corresponding to rotations about the principal axes of the Poincaré sphere. Two of the trajectories provide parameter-free benchmarks, with the real part of the weak value following cos⁡2θ\cos^2θcos2θ and 1/21/21/2. In contrast, the weak value along the third trajectory is sensitive to incoherence and is well described by the single-parameter partial-coherence model, from which a reduced pointer visibility is obtained. Time shifts are extracted from the smoothed derivative of the pulse leading edge with internal calibration, reaching few-picosecond precision on 10 ns optical pulses using commercial components. The same apparatus also gives qualitative access to the imaginary quadrature through the frequency centroid, showing that temporal weak measurements remain accessible and quantitative in partially coherent pulsed systems.
The paper examines how partial temporal coherence modifies post-selected weak-measurement signals for polarization qubits. For an input a∣H⟩+b∣V⟩a|H\rangle+b|V\ranglea∣H⟩+b∣V⟩, a polarization-dependent delay τ\tauτ, and diagonal post-selection, it models the normalized temporal centroid as W~=(∣a∣2+νRe⁡(abˉ))/(1+2νRe⁡(abˉ))\widetilde W=(|a|^2+\nu\operatorname{Re}(a\bar b))/(1+2\nu\operatorname{Re}(a\bar b))W=(∣a∣2+νRe(abˉ))/(1+2νRe(abˉ)), where ν\nuν describes pointer overlap/coherence at the imposed delay. This interpolates between the incoherent population response and the ideal coherent weak-value response.
The experiment uses a commercial multimode 640-nm laser producing 10-ns pulses, a polarization interferometer with approximately 177-ps differential delay, and photodiode/oscilloscope detection. Three polarization trajectories test the model: two predict visibility-independent responses, cos⁡2θ\cos^2\thetacos2θ and 1/21/21/2, while the third constrains ν\nuν. Timing is extracted from the maximum of a smoothed leading-edge derivative, rather than directly from the temporal centroid, with horizontal/vertical reference calibration. Repeated measurements give few-picosecond timing reproducibility. The cos⁡2θ\cos^2\thetacos2θ trajectory has an RMS residual of approximately 0.04; the constant trajectory averages 0.50±0.010.50\pm0.010.50±0.01. A single-parameter fit to the coherence-sensitive trajectory yields ν=0.09±0.05\nu=0.09\pm0.05ν=0.09±0.05.
Fourier analysis of the recorded intensity traces also gives a qualitative angular dependence associated with the magnitude of the imaginary weak value, without a calibrated magnitude or recovered sign. Stated limitations include slow acquisition drifts, angle-calibration uncertainty excluded from per-point statistical errors, and the restriction of a single visibility parameter to a fixed delay. More coherent sources and phase-preserving spectral detection are proposed for approaching ideal weak-value readout and recovering the imaginary-quadrature sign.
Weak measurements are used to amplify small signals, to address foundational questions, and to characterise quantum states without tomography. In direct state reconstruction each amplitude of the state vector is proportional to a single complex weak value, which for a temporal pointer is read from the mean arrival time and the mean frequency of the postselected pulse. Such an experiment requires three quantities to be fixed, the coupling, the angular resolution demanded of the reconstruction, and the set of states over which the method remains usable, and these are commonly set by the available apparatus rather than derived. We derive all three for a Gaussian temporal pointer and an arbitrary postselection state. The states that cannot be reconstructed form a spherical cap centred on the state orthogonal to the postselection, whose geodesic half-angle follows from the largest of three independent thresholds and involves no adjustable parameter. Two states are distinguishable only if they differ by more than a minimal step fixed by the coupling, by the number of incident photons and by the sensitivity of the weak value along the path followed. For an inversion at first order in the coupling the systematic and statistical errors are opposed and fix an optimal coupling that varies as the inverse sixth root of the number of incident photons, whereas an exact inversion at finite coupling removes the systematic error, the remaining bound being one on the two-centroid readout rather than on the inversion, since below an amplitude equal to a quarter of the coupling two states give the same pair of centroids while their profiles differ. These results allow a direct reconstruction experiment to be dimensioned before the apparatus is assembled.
Measuring the polarization state of light has become a challenging study owing to its requirement to simultaneously extract the phase and amplitude parameters with high precision. Here, we present a weak measurement (WM) scheme with two pointers to determine a general polarization state. For the output spectrum from the WM regime, one pointer with the light frequency is used to measure the phase parameter while the other with the post-selected probability is to measure the amplitude. The optimized regime permits the simultaneous measurements of two parameters since the shift results of both two pointers are read in the same working regions. The simulated results show high sensitivity for both two parameters, and high precision that can be comparable with that by other existing schemes. Our scheme can be applied to measure other complex physical effects, providing a method for future ultra-sensitive sensing and metrology.
In this paper, a weak measurement scheme with double pointers (mean value shift and intensity shift of the post-selected light) is presented to simultaneously measure the tiny polarization change (phase and amplitude) of light in a single experimental apparatus. Furthermore, rather than using charge-coupled-device (CCD) to measure the pointer shift, we use the two-channel photoreceiver combined with lock-in amplifier (LIA) to measure the intensities of a split-Gaussian mode in this work. In this way, we introduce two intensity contrast ratios (ICRs) as special pointers to characterize the mean value and intensity shifts. As a result, the measurement precision of the polarization rotation is on the order of magnitude of 10−7rad\,10^{-7}rad10−7radin the experiment. These findings provide a distinctive insight into the weak measurement and have important implications for the accurate measurement of complex optical parameters.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
Weak measurement is a potentially powerful tool for studying post-selected quantum systems. The original approach to weak measurement requires a different von Neumann interaction between the quantum system and measurement pointer for weak values of every different observable. When studying weak values of properties of more than one particle, which is necessary for studying entanglement, these interactions can range from difficult to impossible to implement experimentally. For example, the measurement of properties on a pair of optical photons requires a strong Kerr-like nonlinearity at the two-photon level. In a recent work, we described a new method for extracting weak values of operators that can be expressed as products of two local, single-particle operators by studying the correlations in experimentally feasible local, single-particle measurements. In the present work, that theoretical approach is generalized so that weak values of products of N local, single-particle operators can be extracted from the correlations in N single-particle measurements.
Quantum weak measurements became extremely popular in classical optics to amplify small optical signals for fundamental interests and potential applications. Later, a more general extension, joint weak measurement has been proposed to extract weak value from a joint quantum measurement. However, the detection of joint weak value in the realm of classical optics remains less explored. Here, using the polarization-dependent longitudinal and transverse optical beam shift as a platform, we experimentally realize the quantum joint weak measurement in a classical optical setting. Polarization states are cleverly pre and post-selected, and different single and joint canonical position-momentum observables of the beam are experimentally extracted and subsequently analyzed for successful detection of complex joint weak value. We envision that this work will find usefulness for gaining fundamental insights on quantum measurements and to tackle analogous problems in optics.