This work discusses the single-intensity and difference-intensity detection schemes for lossy Mach–Zehnder Interferometer (MZI) and gives the corresponding optimal conditions to achieve the best phase measurements. The interferometer is fed by a coherent state in one port and a vacuum state in the other. When the core parameters (reflectivities, phase difference) are optimal, the phase sensitivity of these two detection schemes can reach a generalized precision bound: the standard interferometric limit (SIL). In the experiment, we design an MZI with adjustable beam splitters to verify the phase sensitivity optimization compared to the conventional MZI with 50:50 beam splitters. The sensitivity improvements at loss rates from 0.4 to 0.998 are demonstrated based on difference-intensity detection, matching the theoretical results well. With a loss up to 0.998 in one arm, we achieve a sensitivity improvement of 2.5 dB by adjusting reflectivity, which equates to a 5.5 dB sensitivity improvement in single-intensity detection. Such optimal phase measurement methods provide practical solutions for the correct use of resources in lossy interferometers.
This work discusses the single-intensity and difference-intensity detection schemes for lossy Mach–Zehnder Interferometer (MZI) and gives the corresponding optimal conditions to achieve the best phase measurements. The interferometer is fed by a coherent state in one port and a vacuum state in the other. When the core parameters (reflectivities, phase difference) are optimal, the phase sensitivity of these two detection schemes can reach a generalized precision bound: the standard interferometric limit (SIL). In the experiment, we design an MZI with adjustable beam splitters to verify the phase sensitivity optimization compared to the conventional MZI with 50:50 beam splitters. The sensitivity improvements at loss rates from 0.4 to 0.998 are demonstrated based on difference-intensity detection, matching the theoretical results well. With a loss up to 0.998 in one arm, we achieve a sensitivity improvement of 2.5 dB by adjusting reflectivity, which equates to a 5.5 dB sensitivity improvement in single-intensity detection. Such optimal phase measurement methods provide practical solutions for the correct use of resources in lossy interferometers.
In this work, we discuss two phase-measurement methods for the Mach-Zehnder interferometer (MZI) in the presence of internal losses and give the corresponding optimum conditions. We find theoretically that when the core parameters (reflectivities, phase difference) are optimized, the phase sensitivity of the two methods can reach a generalized bound on precision: standard interferometric limit (SIL). In the experiment, we design an MZI with adjustable beam splitting ratios and losses to verify phase sensitivity optimization. The sensitivity improvements at loss rates from 0.4 to 0.998 are demonstrated based on difference-intensity detection, matching the theoretical results well. With a loss up to 0.998 in one arm, we achieve a sensitivity improvement of 2.5 dB by optimizing reflectivity, which equates to a 5.5 dB sensitivity improvement in single-intensity detection. Such optimal phase measurement methods provide practical solutions for the correct use of resources in lossy interferometry.
Improving interferometric phase sensitivity is crucial for high-precision measurements in rapidly developing quantum technologies. The Mach–Zehnder interferometer (MZI) is a versatile tool for analyzing this phenomenon. By splitting and recombining a light beam using beam splitters, the MZI allows for precise phase sensitivity analysis using tools like the quantum Cramér–Rao bound (QCRB) and the quantum Fisher information (QFI). This paper analyzes the phase sensitivity of an MZI in various scenarios using different detection schemes and input states. We compare the single- and two-parameter quantum estimation and their associated QCRB for three phase-shift situations: in both arms; only in the upper arm (asymmetric); and in both arms symmetrically. We then investigate the phase sensitivity under three detection schemes: intensity difference; single-mode intensity; and balanced homodyne. Additionally, we explore the use of Perelomov and Barut–Girardello coherent states, two types of SU(1,1) coherent states, in all scenarios. Notably, we demonstrate that, under optimal conditions, all detection schemes can achieve the QCRB by utilizing SU(1,1) coherent states as input states.
Phase-shifting interferometry (PSI) promises excellent performance for quantitative phase measurement. However, the PSI is commonly realized by utilizing the Mach-Zehnder interferometer (MZI) fed with classical resources, and hence its phase sensitivity is hindered by the photon shot noise. In this paper, we propose to introduce specific phase-shifting algorithms into the well-established quantum-enhanced MZI, seeded by coherent and squeezed vacuum states and followed by single-mode intensity detection and difference intensity detection, to achieve quantitative phase measurement with sensitivity beyond that achieved by the corresponding Mach-Zehnder-type PSI with classical input. We show that when the average photon number of the coherent state is dominant, the optimal phase sensitivity of the Mach-Zehnder-type PSI with coherent plus squeezed vacuum input is better than the phase sensitivity of the Mach-Zehnder-type PSI with single coherent input under the same phase-sensing intensity condition in both of detection setups. We also show that for the typical MZI seeded with a high-power coherent state and a finitely squeezed vacuum state, the combination of intensity detection and phase-shifting algorithm can still improve the sensitivity of quantitative phase measurement. Furthermore, we derive the phase sensitivity of the fixed MZI as well as the quantum Cramér-Rao bound for two detection schemes. Finally, we explore the impacts of photon losses on the phase sensitivity enhancements of the Mach-Zehnder-type PSI and the fixed MZI in the high-intensity regime for each detection setup. The robustness to losses is compared between the Mach-Zehnder-type PSI and the fixed MZI. Our results may be helpful to promote the exploration of quantum-enhanced quantitative phase sensing.
We theoretically study the phase estimation based on a Mach-Zehnder interferometer (MZI) with a two-mode squeezed coherent state. By maximizing the quantum Fisher information, we find that the quantum Cramér-Rao bounds (QCRB) can reach sub-Heisenberg limit under the phase-matched condition. The optimal phase sensitivity can reach the sub-shot noise limit (SNL) and approach the QCRB by employing the intensity difference detection. Meanwhile, compared with the MZI fed with a coherent plus a single-mode squeezed vacuum state, this scheme can have better performance by adjusting the squeezing parameter and the mean photon number. With the same parameter, our scheme shows more sensitive phase measurement than the SU(1,1) interferometer with a coherent plus a vacuum state. We also show that the phase sensitivity of our proposal can still reach the SNL when the loss of the photon is 36%. This scheme can provide potential applications in optical sensors.
ABSTRACT Photon addition operations applied to squeezed states have been shown to significantly enhance phase sensitivity. In this work, we extend this approach by applying photon addition not only to coherent states but also within a Mach–Zehnder interferometer, using coherent and squeezed vacuum states as input. Both intensity‐difference and homodyne detection are used to evaluate photon addition schemes, and their phase sensitivities are compared under ideal and lossy conditions. We also analyze the quantum Fisher information of these two schemes. Results show that both schemes improve phase sensitivity, quantum Fisher information, and robustness against losses. In particular, photon addition within the interferometer performs better. Homodyne detection outperforms intensity difference detection under photon losses. Notably, the two schemes exhibit distinct parameter dependencies, rendering them suitable for different operational scenarios. When the squeezing parameter is small, photon addition employed at the coherent input with intensity difference detection can approach the Heisenberg limit in ideal conditions and can exceed the standard quantum limit in high‐loss conditions. The proposed scheme represents a valuable method for quantum precision measurements. PACS : 03.67.‐a, 05.30.‐d, 42.50,Dv, 03.65.Wj
Interferometry is a widely used technique for precision measurements in both classical and quantum contexts. One way to increase the precision of phase measurements, for example, in a Mach-Zehnder interferometer (MZI), is to use high-intensity lasers. In this paper we study the phase sensitivity of a MZI in two detection setups (difference intensity detection and single-mode intensity detection) and for three input scenarios (coherent, double coherent, and coherent plus squeezed vacuum). For the coherent and double coherent input, both detection setups can reach the quantum Cram\'er-Rao bound, although at different values of the optimal phase shift. The double coherent input scenario has the unique advantage of changing the optimal phase shift by varying the input power ratio.