Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

In-situ measurement of the electron spin polarization by controlling its distribution in atomic ensembles

Xuejing Liu, Yang Li, Chenhui Zhang, Yanhui Hu

Published Apr 27, 2023• 4 citations
Publisher

Abstract

The determination of electron spin polarization by controlling the atomic population distributions of ground states has been proposed. The polarization could be deduced by generating different population symmetries by polarized lights. The polarization of the atomic ensembles was decoded from optical depth in different transmissions of linearly and elliptic polarized lights. The feasibility of the method has been validated theoretically and experimentally. Moreover, the influences of relaxation and magnetic fields are analyzed. The transparency induced by high pump rates are investigated experimentally, and the influences of ellipticity of lights are also discussed. The in-situ polarization measurement was achieved without changing optical path of atomic magnetometer, which provides a new way to interrogate the performance of atomic magnetometer and in-situ monitoring the hyperpolarization of nuclear spins for atomic co-magnetometer.

DOI
10.1364/oe.488083

Related papers

In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers

Kaifeng Yin, Binquan Zhou, Jixi Lu +4 more

Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

IEEE Sensors Journal•Nov 30, 2021•14 citations

Real-Time In Situ Quantum Feedback Control of Electron Spin in Atomic Spin Gyroscopes

Hongyu Pei, Wei Quan, Linlin Yuan +4 more

The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.

IEEE Transactions on Instrumentation and Measurement•Oct 18, 2023•30 citations

Measurement of Equilibrium Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometers via the Steady-State Response to the Triaxial Magnetic Field

Faming Wang, Xiujie Fang, Bozheng Xing +5 more

This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•7 citations

Determination of Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometer Using Transient Response

Junpeng Zhao, Ming Ding, Jixi Lu +5 more

A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.

IEEE Transactions on Instrumentation and Measurement•Apr 27, 2019•67 citations

Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer

Ze Cai, Lihong Duan, Kai Zhang +5 more

Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.

IEEE Sensors Journal•Nov 18, 2024•3 citations

Alkali Atomic Density Detection With Arbitrarily Polarized Light

Xuejing Liu, Menglu Wang, Yuhan Li +3 more

The atomic density of an alkali vapor cell is a critical factor in determining the performance of atomic magnetometers. This paper presents a novel method to detect the density of an alkali atomic ensemble under arbitrary polarization states. By establishing a comprehensive model that correlates the absorption spectrum with the incident light’s polarization, our approach enables real-time and flexible measurements across varying temperatures and polarization angles. Experimental validations are conducted by systematically rotating a quarter-wave plate and controlling the vapor cell temperature, thereby collecting transmission spectra at multiple polarizations. The results demonstrate that the proposed method simplifies density measurements while preserving high accuracy, laying a solid foundation for further research on Spin-Exchange Relaxation-Free (SERF) atomic magnetometers. This technique serves as a versatile and effective tool for in-situ monitoring of alkali metal vapor density in various sensor applications.

IEEE Sensors Journal•Apr 7, 2025•1 citation
The determination of electron spin polarization by controlling the atomic population distributions of ground states has been proposed. The polarization could be deduced by generating different population symmetries by polarized lights. The polarization of the atomic ensembles was decoded from optical depth in different transmissions of linearly and elliptic polarized lights. The feasibility of the method has been validated theoretically and experimentally. Moreover, the influences of relaxation and magnetic fields are analyzed. The transparency induced by high pump rates are investigated experimentally, and the influences of ellipticity of lights are also discussed. The in-situ polarization measurement was achieved without changing optical path of atomic magnetometer, which provides a new way to interrogate the performance of atomic magnetometer and in-situ monitoring the hyperpolarization of nuclear spins for atomic co-magnetometer.
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.
The atomic spin gyroscope (ASG), based on spin-exchange relaxation-free (SERF) co-magnetometers, is poised to become the next generation of high-precision inertial sensors. However, the long-term stability of the gyro can be limited by electron spin polarization. In this study, we investigate a novel real-time, in situ quantum feedback control technique for electron spin polarization in ASGs. By varying the pumping rates, we analyze the gyroscope’s response to the modulation magnetic field, finding that electron polarization dramatically affects the magnetic field response properties of ASGs. It’s demonstrated that the amplitude or phase of the electron spin resonance can be locked for in situ control of electron spin polarization in real-time. A K-Rb-21Ne co-magnetometer is established to implement the proposed method, where a transverse modulating magnetic field is applied to resonate with the electron spin. The lock-in amplification (LIA) technique is used to obtain the amplitude or phase of the electron spin resonance, and the electron spin polarization is closed-loop controlled by locking the second harmonic resonance amplitude or phase. The gyro signal is extracted from the first harmonic of the electron spin resonance. Our experimental results show that real-time in situ feedback control of electron spin significantly improves ASG’s long-term stability and suppresses low-frequency noise. This proposed method has broad application prospects, including optically pumped magnetometers (OPMs), nuclear magnetic resonance gyroscopes (NMRGs), and co-magnetometers.
This study proposes an in situ method for measuring the equilibrium spin polarization and its longitudinal spatial distribution in a spin-exchange relaxation-free (SERF) atomic magnetometer. The total relaxation rate was determined by analyzing the steady-state response of the magnetometer to the triaxial magnetic field. The transfer coefficient between spin polarization along the probe beam axis and the steady-state response was derived from the optical depth of the probe light and the incident/transmitted power through the vapor cell. By applying a DC magnetic field along the sensitive axis and combining the total relaxation rate with the transfer coefficient, the equilibrium spin polarization value under zero-field conditions was obtained. The equilibrium spin polarization distribution along the pump beam propagation direction was measured, showing consistent trends with simulation results, with a maximum relative error of less than 5%. The expanded uncertainty of the proposed equilibrium spin polarization measurement method ranges from 0.8% to 9.7%. The advantages of this method include no requirement for additional optical field or magnetic field modulation, immunity to temperature and temperature gradients, and the capability to directly determine the equilibrium spin polarization value.
A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.
Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.
The atomic density of an alkali vapor cell is a critical factor in determining the performance of atomic magnetometers. This paper presents a novel method to detect the density of an alkali atomic ensemble under arbitrary polarization states. By establishing a comprehensive model that correlates the absorption spectrum with the incident light’s polarization, our approach enables real-time and flexible measurements across varying temperatures and polarization angles. Experimental validations are conducted by systematically rotating a quarter-wave plate and controlling the vapor cell temperature, thereby collecting transmission spectra at multiple polarizations. The results demonstrate that the proposed method simplifies density measurements while preserving high accuracy, laying a solid foundation for further research on Spin-Exchange Relaxation-Free (SERF) atomic magnetometers. This technique serves as a versatile and effective tool for in-situ monitoring of alkali metal vapor density in various sensor applications.