Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Spin-Dependent Dynamics of Photocarrier Generation in Electrically Detected Nitrogen-Vacancy-Based Quantum Sensing

Hiroki Morishita, Naoya Morioka, Testuri Nishikawa, Hajime Yao, Shinobu Onoda, Hiroshi Abe, Takeshi Ohshima, Norikazu Mizuochi

Published Mar 20, 2023• 11 citations
Publisher

Abstract

Electrical detection of nitrogen-vacancy (N-V) centers in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors and has the potential to achieve a higher collection efficiency than that of optical techniques. However, the mechanism for the electrical detection of N-V spins is not fully understood. In this study, we observe positive contrast in photocurrent detected magnetic resonance (PDMR). Note that negative PDMR contrast is usually observed. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by N-V centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of N-V centers. Furthermore, we demonstrate ac magnetic field sensing using spin coherence with the PDMR technique. ac magnetic field measurement with the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. Here, we introduce noise suppression using a phase-cycling-based noise-canceling technique. We demonstrate electrically detected ac magnetic field sensing with a sensitivity of 29 nT ${\mathrm{Hz}}^{\ensuremath{-}1/2}$. Finally, we discuss sensitivity enhancement based on the proposed model.

DOI
10.1103/physrevapplied.19.034061

Related papers

Spin-Dependent Photocarrier Generation Dynamics in Electrically Detected Nitrogen-Vacancy-Based Quantum Sensor

Hiroki Morishita, Naoya Morioka, Tetsuri Nishikawa +5 more

Electrical detection of a nitrogen-vacancy (NV) center in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors. However, the mechanism for the electrical detection of NV spins is not fully understood. In this study, we observe positive contrast in photoelectrically detected magnetic resonance (PDMR) despite the usually observed negative PDMR contrast. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by NV centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of NV centers. Furthermore, we demonstrate alternating-current (AC) magnetic field sensing using spin coherence with the PDMR technique using a phase-cycling-based noise-canceling technique to suppress the noise from a fluctuating magnetic environment. We obtained the sensitivity of AC magnetic-field of ${\sim}29{\text{nT}}/\sqrt {{\mathbf{Hz}}} $ with the PDMR technique.

IEEE International Magnetic Conference - Short Papers (INTERMAG Short Papers)•May 1, 2023•1 citation

High PDMR contrast in single NV centres and related photocurrent properties

Michael Petrov, Boo Carmans, Josef Soucek +4 more

This paper aims to extend the understanding of the mechanism of photo-electrical detection of magnetic resonance (PDMR) in nitrogen-vacancy (NV) centres. This technique is particularly important for development of solid-state quantum computing platforms. In particular, we report on the new insight in the photocurrent (PC) generation and charge cycling in the single NV centre, which is related to PDMR contrast reaching 50\% and above. We develop a technique to locate PC related features. We find that electrons generated at the NV centre are stored in interface trap levels and establish that the interface states serve as an amplifier that can be driven by introducing a second laser into our confocal setup. We show that controlling these interface states allows one to significantly enhance the PDMR contrast. We develop a model that consistently explains observed amplification effects even without the application of a bias voltage.

quant-pharXiv:2603.27911•Mar 31, 2026

Spin-Dependent Photocarrier Generation Dynamics in NV-Based Quantum Sensor with Electrical Detection Technique

Hiroki Morishita, Naoya Morioka, Tetsuri Nishikawa +5 more

We demonstrate AC magnetic field sensing using spin coherence with the PDMR technique. AC magnetic field sensing using the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. We demonstrate AC magnetic field sensing with the PDMR technique by using a phase-cycling-based noise-canceling technique to suppress the noise. We observe electrically detected AC magnetic field sensing with a sensitivity of ~29 nT/√Hz. We will discuss the mechanism of PDMR of the NV centers and the sensitivity of AC magnetic field sensing with the electrical detection.

•Dec 12, 2023•0 citations

Real-Time Magnetic Field Sensing based on Microwave Frequency Modulated Photocurrent of Nitrogen-Vacancy Centers in Diamond

Xuan-Ming Shen, Qilong Wu, Huihui Yu +6 more

While photoelectric detection of magnetic resonance (PDMR) can be applied to miniaturize nitrogen-vacancy (NV) center-based quantum sensors, real demonstration of PDMR-based magnetic field sensing remains as a distinctive challenge. To tackle this challenge, in this article, we fabricate diamond samples with electrodes and microwave antenna on the surface, and realize PDMR by detecting photocurrent in picoampere range via various lock-in amplifying modes. We obtain a theoretical and experimental sensitivity 397 nT/Hz and 921 nT/Hz of magnetic field detection in DC-10 Hz range with a laser intensity and microwave frequency modulation mode, respectively, and demonstrate for the first time, a real-time tracking of alternating magnetic field with a standard deviation of 1.5 uT. Furthermore, we investigate systematically the dependence of the PDMR contrast, linewidth and the sensitivity on the laser and microwave power, and find a perfect agreement with a master equation-based theory. Thus, our results represent a critical step forward in transitioning PDMR from a spectroscopic technique to a practical sensing modality.

quant-pharXiv:2602.07926•Feb 10, 2026

Photoelectric Detection of Nitrogen‐Vacancy Centers Magnetic Resonances in Diamond: Role of Charge Exchanges with Other Optoelectrically Active Defects

Emilie Bourgeois, Josef Soucek, Jaroslav Hrubý +2 more

Abstract The photoelectric detection of nitrogen‐vacancy (NV) magnetic resonance (PDMR) in diamond, used for spin state detection and based on reading the photocurrent resulting from NV ionization, offers physical and technical advantages for the development of miniaturized and scalable quantum sensors, as well as solid‐state quantum information devices integrated with electronics. Charge exchanges between NV centers and other optoelectrically active defects in diamond are an essential part of the PDMR scheme, impacting the spin‐state control and the performances of the photoelectric readout. Through experimental characterization and modeling, processes governing the spin‐state contrast, in particular the hole carrier contribution to the photocurrent and the role of acceptor‐type defects are discussed. Such acceptor defects can act as traps for free electrons resulting from NV photoionization. Consequently, the hole current can increase at resonance, ultimately leading to an inversion of the sign of PDMR resonances, i.e. to a positive spin contrast. Based on these findings, a method to improve PDMR performances in terms of spin contrast and photoelectric detection rate by selectively ionizing low‐energy acceptor defects using a bias red illumination is proposed. This method is shown to lead to a significant improvement of the photoelectric spin detection sensitivity, important for future practical devices.

Advanced Quantum Technologies•Mar 17, 2022•11 citations

Photoelectric detection of electron spin resonance of nitrogen-vacancy centres in diamond

Emilie Bourgeois, Andrey Jarmola, Petr Siyushev +5 more

The readout of negatively charged nitrogen-vacancy centre electron spins is essential for applications in quantum computation, metrology and sensing. Conventional readout protocols are based on the detection of photons emitted from nitrogen-vacancy centres, a process limited by the efficiency of photon collection. We report on an alternative principle for detecting the magnetic resonance of nitrogen-vacancy centres, allowing the direct photoelectric readout of nitrogen-vacancy centres spin state in an all-diamond device. The photocurrent detection of magnetic resonance scheme is based on the detection of charge carriers promoted to the conduction band of diamond by two-photon ionization of nitrogen-vacancy centres. The optical and photoelectric detection of magnetic resonance are compared, by performing both types of measurements simultaneously. The minima detected in the measured photocurrent at resonant microwave frequencies are attributed to the spin-dependent ionization dynamics of nitrogen-vacancy, originating from spin-selective non-radiative transitions to the metastable singlet state.

arXiv:1502.07551•Nature Communications•Oct 21, 2015•187 citations
Electrical detection of nitrogen-vacancy (N-V) centers in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors and has the potential to achieve a higher collection efficiency than that of optical techniques. However, the mechanism for the electrical detection of N-V spins is not fully understood. In this study, we observe positive contrast in photocurrent detected magnetic resonance (PDMR). Note that negative PDMR contrast is usually observed. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by N-V centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of N-V centers. Furthermore, we demonstrate ac magnetic field sensing using spin coherence with the PDMR technique. ac magnetic field measurement with the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. Here, we introduce noise suppression using a phase-cycling-based noise-canceling technique. We demonstrate electrically detected ac magnetic field sensing with a sensitivity of 29 nT Hz\ensuremath−1/2{\mathrm{Hz}}^{\ensuremath{-}1/2}Hz\ensuremath−1/2. Finally, we discuss sensitivity enhancement based on the proposed model.
Electrical detection of a nitrogen-vacancy (NV) center in diamond is advantageous for developing and integrating quantum information processing devices and quantum sensors. However, the mechanism for the electrical detection of NV spins is not fully understood. In this study, we observe positive contrast in photoelectrically detected magnetic resonance (PDMR) despite the usually observed negative PDMR contrast. To discuss the sign of the PDMR contrast, we numerically analyze the dynamics of photocarrier generation by NV centers using a seven-level rate model. It is found that the sign of the PDMR contrast depends on the difference in the photocurrent generated from the excited states and the metastable state of NV centers. Furthermore, we demonstrate alternating-current (AC) magnetic field sensing using spin coherence with the PDMR technique using a phase-cycling-based noise-canceling technique to suppress the noise from a fluctuating magnetic environment. We obtained the sensitivity of AC magnetic-field of ${\sim}29{\text{nT}}/\sqrt {{\mathbf{Hz}}} $ with the PDMR technique.
This paper aims to extend the understanding of the mechanism of photo-electrical detection of magnetic resonance (PDMR) in nitrogen-vacancy (NV) centres. This technique is particularly important for development of solid-state quantum computing platforms. In particular, we report on the new insight in the photocurrent (PC) generation and charge cycling in the single NV centre, which is related to PDMR contrast reaching 50\% and above. We develop a technique to locate PC related features. We find that electrons generated at the NV centre are stored in interface trap levels and establish that the interface states serve as an amplifier that can be driven by introducing a second laser into our confocal setup. We show that controlling these interface states allows one to significantly enhance the PDMR contrast. We develop a model that consistently explains observed amplification effects even without the application of a bias voltage.
We demonstrate AC magnetic field sensing using spin coherence with the PDMR technique. AC magnetic field sensing using the PDMR technique is still challenging because the noise from a fluctuating magnetic environment is greater than the measured signal. We demonstrate AC magnetic field sensing with the PDMR technique by using a phase-cycling-based noise-canceling technique to suppress the noise. We observe electrically detected AC magnetic field sensing with a sensitivity of ~29 nT/√Hz. We will discuss the mechanism of PDMR of the NV centers and the sensitivity of AC magnetic field sensing with the electrical detection.
While photoelectric detection of magnetic resonance (PDMR) can be applied to miniaturize nitrogen-vacancy (NV) center-based quantum sensors, real demonstration of PDMR-based magnetic field sensing remains as a distinctive challenge. To tackle this challenge, in this article, we fabricate diamond samples with electrodes and microwave antenna on the surface, and realize PDMR by detecting photocurrent in picoampere range via various lock-in amplifying modes. We obtain a theoretical and experimental sensitivity 397 nT/Hz and 921 nT/Hz of magnetic field detection in DC-10 Hz range with a laser intensity and microwave frequency modulation mode, respectively, and demonstrate for the first time, a real-time tracking of alternating magnetic field with a standard deviation of 1.5 uT. Furthermore, we investigate systematically the dependence of the PDMR contrast, linewidth and the sensitivity on the laser and microwave power, and find a perfect agreement with a master equation-based theory. Thus, our results represent a critical step forward in transitioning PDMR from a spectroscopic technique to a practical sensing modality.
Abstract The photoelectric detection of nitrogen‐vacancy (NV) magnetic resonance (PDMR) in diamond, used for spin state detection and based on reading the photocurrent resulting from NV ionization, offers physical and technical advantages for the development of miniaturized and scalable quantum sensors, as well as solid‐state quantum information devices integrated with electronics. Charge exchanges between NV centers and other optoelectrically active defects in diamond are an essential part of the PDMR scheme, impacting the spin‐state control and the performances of the photoelectric readout. Through experimental characterization and modeling, processes governing the spin‐state contrast, in particular the hole carrier contribution to the photocurrent and the role of acceptor‐type defects are discussed. Such acceptor defects can act as traps for free electrons resulting from NV photoionization. Consequently, the hole current can increase at resonance, ultimately leading to an inversion of the sign of PDMR resonances, i.e. to a positive spin contrast. Based on these findings, a method to improve PDMR performances in terms of spin contrast and photoelectric detection rate by selectively ionizing low‐energy acceptor defects using a bias red illumination is proposed. This method is shown to lead to a significant improvement of the photoelectric spin detection sensitivity, important for future practical devices.
The readout of negatively charged nitrogen-vacancy centre electron spins is essential for applications in quantum computation, metrology and sensing. Conventional readout protocols are based on the detection of photons emitted from nitrogen-vacancy centres, a process limited by the efficiency of photon collection. We report on an alternative principle for detecting the magnetic resonance of nitrogen-vacancy centres, allowing the direct photoelectric readout of nitrogen-vacancy centres spin state in an all-diamond device. The photocurrent detection of magnetic resonance scheme is based on the detection of charge carriers promoted to the conduction band of diamond by two-photon ionization of nitrogen-vacancy centres. The optical and photoelectric detection of magnetic resonance are compared, by performing both types of measurements simultaneously. The minima detected in the measured photocurrent at resonant microwave frequencies are attributed to the spin-dependent ionization dynamics of nitrogen-vacancy, originating from spin-selective non-radiative transitions to the metastable singlet state.