This paper reports on the extraction of the equivalent circuit model parameters of a physically defined silicon quantum dot at a cryogenic temperature and design of the impedance matching circuits to improve the performance of a charge sensor for radio-frequency (RF) reflectometry. The I-V characteristics and the S-parameters of the quantum dot device are measured around a Coulomb peak at 4.2 K. The measured results are modeled by an RC parallel circuit, and the model parameters for the quantum dot device were obtained. We consider three impedance matching circuits for RF reflectometry of a quantum dot: shunt capacitor-series inductor type, shunt inductor-series capacitor type, and shunt inductor-series inductor-type. We formulate and compare the sensitivity and bandwidth of RF reflectometry for the three types of circuits. The analysis should be useful for selecting the optimal matching circuit and the circuit parameters for given equivalent circuit parameters and working frequency. This procedure is demonstrated for a quantum dot with the characterized model circuit along with simulated performance. This design technique of matching circuit for RF reflectometry can be applied to any device that can be represented by an RC parallel circuit. These results will facilitate to realize fast semiconductor qubit readout in various quantum dot platforms.
This paper reports on the extraction of the equivalent circuit model parameters of a physically defined silicon quantum dot at a cryogenic temperature and design of the impedance matching circuits to improve the performance of a charge sensor for radio-frequency (RF) reflectometry. The I-V characteristics and the S-parameters of the quantum dot device are measured around a Coulomb peak at 4.2 K. The measured results are modeled by an RC parallel circuit, and the model parameters for the quantum dot device were obtained. We consider three impedance matching circuits for RF reflectometry of a quantum dot: shunt capacitor-series inductor type, shunt inductor-series capacitor type, and shunt inductor-series inductor-type. We formulate and compare the sensitivity and bandwidth of RF reflectometry for the three types of circuits. The analysis should be useful for selecting the optimal matching circuit and the circuit parameters for given equivalent circuit parameters and working frequency. This procedure is demonstrated for a quantum dot with the characterized model circuit along with simulated performance. This design technique of matching circuit for RF reflectometry can be applied to any device that can be represented by an RC parallel circuit. These results will facilitate to realize fast semiconductor qubit readout in various quantum dot platforms.
Frequency-multiplexed radio-frequency (RF) reflectometry is a promising technique for large-scale quantum dot-based qubit systems because it enables simultaneous readout of multiple qubits and helps to reduce the wiring density in peripheral circuits. However, in the conventional L-C-type matching circuits, resonator frequency tunability is limited by poor design flexibility of the shunt capacitance and hence the circuit. Recently, L-L-type matching circuits comprising a series and a shunt inductor have been proposed to address this issue. Here, we report RF reflectometry readout of silicon quantum dot-based charge sensors embedded in L-L-type circuits. We determine the inductance values for target resonance frequencies based on our equivalent circuit model that incorporates the parasitic elements of the inductors and demonstrate resonator frequency tunability of up to 1 GHz with 3-dB resonator bandwidths on the order of MHz. The measured conductance sensitivities, on the order of 10−5(e2/h)/Hz at 4 K, are only moderately dependent on the resonance frequency up to 630 MHz. These results highlight the prospects of L-L-type matching circuits for rapid and multiplex reflectometry readout of semiconductor spin qubits.
Radio-frequency reflectometry allows for fast and sensitive electrical readout of charge and spin qubits hosted in quantum dot devices coupled to resonant circuits. Optimizing readout, however, requires frequency tuning of the resonators and impedance matching. This is difficult to achieve using conventional semiconductor or ferroelectric-based varactors in the detection circuit as their performance degrades significantly in the mK temperature range relevant for solid-state quantum devices. Here we explore a different type of material, strontium titanate, a quantum paraelectric with exceptionally large field-tunable permittivity at low temperatures. Using strontium titanate varactors we demonstrate perfect impedance matching and resonator frequency tuning at 6 mK and characterize the varactors at this temperature in terms of their capacitance tunability, dissipative losses and magnetic field sensitivity. We show that this allows us to optimize the radio-frequency readout signal-to-noise ratio of carbon nanotube quantum dot devices to achieve a charge sensitivity of 4.8 μe/Hz1/2 and capacitance sensitivity of 0.04 aF/Hz1/2.
Radio-frequency reflectometry techniques enable high-bandwidth readout of semiconductor quantum dots. Careful impedance matching of the resonant circuit is required to achieve high sensitivity, which, however, proves challenging at cryogenic temperatures. Gallium arsenide--based voltage-tunable capacitors, so-called varactor diodes, can be used for in situ tuning of the circuit impedance but deteriorate and fail at temperatures below 10 K and in magnetic fields. Here, we investigate a varactor based on strontium titanate with a hyperabrupt capacitance-voltage characteristic, i.e., a capacitance tunability similar to the best gallium arsenide--based devices. The varactor design introduced here is compact, scalable, and easy to wire bond, with an accessible capacitance range from 45 pF to 3.2 pF. We tune a resonant inductor-capacitor circuit to perfect impedance matching and observe robust temperature- and field-independent matching down to 11 mK and up to 2 T in-plane field. Finally, we perform gate-dispersive charge sensing on a germanium-silicon core-shell nanowire hole double quantum dot, paving the way toward gate-based single-shot spin readout. Our results bring small magnetic field--resilient highly tunable varactors to mK temperatures, expanding the toolbox of cryo-radio-frequency applications.
Quantum computing has emerged as a promising technology for next-generation information processing, utilizing semiconductor quantum dots as one of the candidates for quantum bits. Radio-frequency (rf) reflectometry plays an important role in the readout of quantum dots but requires a precise rf measurement technique at cryogenic temperatures. While cryogenic calibration techniques, essential for rf reflectometry, have been developed, on-board calibration near the device remains an important challenge. In this study, we develop an on-board calibrated rf measurement system operating at 4 K for characterizing SrTiO3-based varactors, which are promising components for tunable impedance matching circuits. Our system enables accurate measurements by eliminating errors associated with long rf circuit lines. We investigate the effects of annealing conditions, crystal orientation, and Ca doping of SrTiO3 crystals on the varactor properties in the frequency range for rf reflectometry. Our results provide insights for optimizing these components for cryogenic rf applications in quantum information processing systems.
This thesis focuses on implementing radio frequency (rf) reflectometry techniques for dispersive detection of charge and spin dynamics in nanoscale devices. I have investigated three aspects of rf reflectometry using state-of-the-art silicon (Si) complementary metal-oxide-semiconductor (CMOS) nanowire field effect transistors (NWFETs). First, a high-sensitivity capacitive gate-based charge sensor is developed by optimising the external matching circuit to detect capacitive changes in the high frequency resonator. A new circuit topology is used where superconducting niobium nitride (NbN) inductor is connected in parallel with a single-gate Si NWFET resulting in resonators with loaded Q-factors in the 400-800 range. For a resonator operating at 330 MHz, I have achieved a charge sensitivity of 7.7 μe/Hz and, when operating at 616 MHz, I get 1.3 μe/Hz. This gate-based sensor can be used for fast, accurate and scalable techniques for quantum state readout in Si CMOS based quantum computing. Second, this new circuit topology for the resonator is used with a dual-gate Si NWFET. This dual-gate device geometry provides access to a double quantum dot (DQD) system in few electron regime. The spin-state of the two-electron DQD system is detected dispersively using Pauli spin blockade between joint singlet S(2,0) and triplet T−(1,1) states in a finite magnetic field B. The singlet-triplet relaxation time T1 at B=4.5~T is measured to be $\sim$1 ms using standard homodyne detection technique. Third, I expand the range of applications of gate-based sensing to accurate temperature measurements. I have experimentally demonstrated a primary thermometer by embedding a single-gate Si NWFET with the rf capacitive gate-based sensor. The thermometer, termed as gate-based electron thermometer (GET), relies on cyclic electron tunneling between discrete energy levels of a quantum dot and a single electron reservoir in the NWFET. I have found that the full-width-half-maximum (FWHM) of the resonator phase response depends linearly with temperature via well known physical law by using the ratio kB/e between the Boltzmann constant and the electron charge. The GET is also found to be magnetic field independent like other primary thermometers such as Coulomb blockade and shot noise thermometers.
Electrical readout of spin qubits requires fast and sensitive measurements, which are hindered by poor impedance matching to the device. We demonstrate perfect impedance matching in a radio-frequency readout circuit, using voltage-tunable varactors to cancel out parasitic capacitances. An optimized capacitance sensitivity of 1.6 aF/√Hz is achieved at a maximum source-drain bias of 170−μV root-mean-square and with a bandwidth of 18 MHz. Coulomb blockade in a quantum-dot is measured in both conductance and capacitance, and the two contributions are found to be proportional as expected from a quasistatic tunneling model. We benchmark our results against the requirements for single-shot qubit readout using quantum capacitance, a goal that has so far been elusive.