Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics

Two Paths to a Magnetic Gradiometer

Marric Stephens

Published Nov 23, 2022• 0 citations
Publisher

Abstract

Two Paths to a Magnetic Gradiometer Atomic magnetometers employing two new geometries can exclude background fields to pick up weak, nearby radio-frequency sources.
DOI
10.1103/physics.15.s162

Related papers

An atomic magnetic gradiometer with 1/τ uncertainty property based on the self-sustaining method

Qin Zhao, Boling Fan, Shiguang Wang +1 more

The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.

International Conference on Photonics and Optical Engineering•Jan 24, 2019•0 citations

“Fictitious” Magnetic Fields for Atomic Magnetometers

Martin Rodriguez-Vega

Researchers have achieved dual-axis magnetic-field detection using an atomic magnetometer architecture with only optical instruments.

Physics•Jan 16, 2024•0 citations

Quantum Magnetometers for Infrastructure Inspection and Monitoring

Muhammad Mahmudul Hasan, Ingrid Torres, Alex Krasnok

Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries and power equipment. Magnetic methods are attractive because they can sense through coatings, insulation, and concrete cover without couplants, but field performance is often limited by lift-off, low-frequency drift, background magnetic noise, and the weak low-frequency response of pickup coils. This review examines two room-temperature quantum receiver platforms: optically pumped atomic magnetometers (OPMs) and nitrogen-vacancy (NV) diamond magnetometers. Rather than treating them as stand-alone sensors, we compare them as parts of a full measurement chain that includes source physics, geometry, readout, calibration, and interpretation. The literature is organized into four magnetic signal classes: driven induction responses, leakage fields in magnetic flux leakage inspection, passive self-fields linked to stress or corrosion, and fields produced by operational currents. OPMs are strongest for low-frequency, phase-referenced induction measurements, while NV sensors are strongest for near-surface field mapping, vector or gradient measurements, and differential current sensing in compact solid-state heads. Across all applications, deployment depends less on best-case sensitivity than on usable bandwidth, dynamic range, background rejection, geometry control, calibration, and validation. The clearest path to field use is therefore robust instrument engineering tied to qualification methods that reflect real inspection conditions.

physics.app-phCross-listedarXiv:2604.03288•Mar 27, 2026

Frequency Tunable Atomic Magnetometer based on an Atom Interferometer

Frank A. Narducci, Danielle Braje, Jon P. Davis +1 more

Bulletin of the American Physical Society•Jun 4, 2013•0 citations

A zero-field atomic gradiometer with elliptically polarized laser-pumped used for biomagnetic measurement

Kaifeng Yin, Jing Wang, Zhi Liu +3 more

A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.

Applied Optics and Photonics China (AOPC): Optoelectronics and Nanophotonics•Nov 5, 2020•2 citations

Progress in high sensitive atomic magnetometers

Guobin Liu, Xian-Ping Sun, 顾思洪 +2 more

Wuli•Jan 1, 2012•1 citation
The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.
Damage in infrastructure is often hidden until it becomes costly or dangerous. Common examples include corrosion under insulation, early fatigue damage in steel, corrosion of embedded reinforcement, and abnormal current flow in batteries and power equipment. Magnetic methods are attractive because they can sense through coatings, insulation, and concrete cover without couplants, but field performance is often limited by lift-off, low-frequency drift, background magnetic noise, and the weak low-frequency response of pickup coils. This review examines two room-temperature quantum receiver platforms: optically pumped atomic magnetometers (OPMs) and nitrogen-vacancy (NV) diamond magnetometers. Rather than treating them as stand-alone sensors, we compare them as parts of a full measurement chain that includes source physics, geometry, readout, calibration, and interpretation. The literature is organized into four magnetic signal classes: driven induction responses, leakage fields in magnetic flux leakage inspection, passive self-fields linked to stress or corrosion, and fields produced by operational currents. OPMs are strongest for low-frequency, phase-referenced induction measurements, while NV sensors are strongest for near-surface field mapping, vector or gradient measurements, and differential current sensing in compact solid-state heads. Across all applications, deployment depends less on best-case sensitivity than on usable bandwidth, dynamic range, background rejection, geometry control, calibration, and validation. The clearest path to field use is therefore robust instrument engineering tied to qualification methods that reflect real inspection conditions.
A new design of compact zero-field atomic gradiometer was proposed and integrated using alkali vapor cell and customized optical components. This gradiometer used two parallel elliptically polarized lights, whose output intensity was measured to perform gradient magnetic field detection, respectively. To improve the gradiometer’s sensitivity of the magnetic field detection, the gradiometer was operated in the spin-exchange relaxation-free (SERF) regime. For the sensitivity study, the gradiometer was placed in a person-sized four-layer μ-metal magnetic shielding. With the magnetic shield closed up, the sensitivity of each channel was near 34 fT/ √ Hz, and the corresponding gradient sensitivity could reach 14 fT/√ Hz/cm on a 1cm baseline. When the cover of magnetic shielding was removed, the magnetometer sensitivity of single channel was about 90 fT/√ Hz, and the corresponding gradient sensitivity could reach 34 fT/√ Hz/cm. The experimental results implied that in a poor magnetic shielding environment, the performance of magnetometer was limited due to the fluctuations of the environmental magnetic field, while the gradiometer could work well.