Annual Meeting Optical Society of America

Uncertainty relations and interferometers

Mark S. Hillery, Leonard D. Mlodinow

Published Jan 1, 1992• 0 citations
Publisher

Abstract

As was originally pointed out by Caves, squeezed light can be used to increase the accuracy of interferometric phase measurements. This analysis was carried further by Yurke, McCall, and Klauder, who used group theory to examine the ultimate sensitivity of conventional interferometers and also those constructed from four-wave mixers. Here we consider interferometers composed of mixtures of beam splitters, four-wave mixers, and degenerate parametric amplifiers. We show that each interferometer can be characterized by an uncertainty relation whose minimum uncertainty states can be used to explore its ultimate accuracy. The variables in the uncertainty relation are quadratic in the mode operators, which allows us to connect the study of improved interferometric measurements to recent work on higher-order squeezing.

DOI
10.1364/oam.1992.fi2

Related papers

Interferometers and minimum-uncertainty states

Mark S. Hillery, Leonard D. Mlodinow

Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.

Physical Review A•Aug 1, 1993•97 citations

Quantum Interferometer Combining Squeezing and Parametric Amplification

Xiaojie Zuo, Zhihui Yan, Yanni Feng +4 more

High precision interferometers are the building blocks of precision metrology and the ultimate interferometric sensitivity is limited by the quantum noise. Here, we propose and experimentally demonstrate a compact quantum interferometer involving two optical parametric amplifiers and the squeezed states generated within the interferometer are directly used for the phase-sensing quantum state. By both squeezing shot noise and amplifying phase-sensing intensity the sensitivity improvement of 4.86±0.24 dB beyond the standard quantum limit is deterministically realized and a minimum detectable phase smaller than that of all present interferometers under the same phase-sensing intensity is achieved. This interferometric system has significantly potential applications in a variety of measurements for tiny variances of physical quantities.

arXiv:2005.01911•Physical Review Letters•May 1, 2020•78 citations

Squeezed state enhanced polarization Interferometry

Philippe Grangier, Bernard Yurke, Richard E. Slusher

Since the first proposal by Caves1 that squeezed light could be used to enhance the sensitivity of a gravitational wave interferometric antenna, squeezed states have been demonstrated in the laboratory but not yet used in an actual measurement system. This paper describes a polarization interferometer experiment, operated with a squeezed light source, designed to improve the interferometer sensitivity beyond the standard quantum limit. The interferometer consists of two polarization beam splitters, whose axes are oriented 45° with respect to each other. Linearly polarized incident laser light is transmitted by the first polarizer and split by the second one, which also acts as the splitter for a balanced homodyne detector. A rotation of the polarization between the two polarizers can be detected with quantum-limited sensitivity (e.g., ±1 μrad). The squeezed light entering the other port of the interferometer is produced using a χ2 crystal (KTP) in an optical cavity, pumped by a frequency-doubled cw ring Nd:YAG laser. The interferometer sensitivity can thus be increased by a factor depending on the degree of squeezing achieved and on the detector quantum efficiency. Sensitivity increases by factors between 2 and 3 are predicted, and current performance is described.

Annual Meeting Optical Society of America•Jan 1, 1987•0 citations

Quantum metrology with parametric amplifier-based photon correlation interferometers

Florian Hudelist, Jia Kong, Cunjin Liu +3 more

Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.

Nature Communications•Jan 29, 2014•438 citations

Squeezing with fiber Sagnac loop and sub-shot-noise measurement

H. A. Haus, K. Bergman, Luc Boivin +2 more

Squeezed states of light are minimum uncertainty states for which the mean square fluctuations in phase and in quadrature with respect to a reference signal are unequal. Among other interesting properties, they provide improved sensitivity of optical interferometric phase measurements. To understand this potential, one must note that quantum theory imposes measurement uncertainty only on a pair of noncommuting variables; the measurement of any one quantum observable could be done with no uncertainty.>

Nonlinear Optics•Dec 17, 2002•0 citations

PHASE MEASUREMENTS WITH A TWO-MODE SQUEEZED STATE OF LIGHT.

Gupta, Prasoon

Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.

•Jan 1, 2019•0 citations
As was originally pointed out by Caves, squeezed light can be used to increase the accuracy of interferometric phase measurements. This analysis was carried further by Yurke, McCall, and Klauder, who used group theory to examine the ultimate sensitivity of conventional interferometers and also those constructed from four-wave mixers. Here we consider interferometers composed of mixtures of beam splitters, four-wave mixers, and degenerate parametric amplifiers. We show that each interferometer can be characterized by an uncertainty relation whose minimum uncertainty states can be used to explore its ultimate accuracy. The variables in the uncertainty relation are quadratic in the mode operators, which allows us to connect the study of improved interferometric measurements to recent work on higher-order squeezing.
Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.
High precision interferometers are the building blocks of precision metrology and the ultimate interferometric sensitivity is limited by the quantum noise. Here, we propose and experimentally demonstrate a compact quantum interferometer involving two optical parametric amplifiers and the squeezed states generated within the interferometer are directly used for the phase-sensing quantum state. By both squeezing shot noise and amplifying phase-sensing intensity the sensitivity improvement of 4.86±0.24 dB beyond the standard quantum limit is deterministically realized and a minimum detectable phase smaller than that of all present interferometers under the same phase-sensing intensity is achieved. This interferometric system has significantly potential applications in a variety of measurements for tiny variances of physical quantities.
Since the first proposal by Caves1 that squeezed light could be used to enhance the sensitivity of a gravitational wave interferometric antenna, squeezed states have been demonstrated in the laboratory but not yet used in an actual measurement system. This paper describes a polarization interferometer experiment, operated with a squeezed light source, designed to improve the interferometer sensitivity beyond the standard quantum limit. The interferometer consists of two polarization beam splitters, whose axes are oriented 45° with respect to each other. Linearly polarized incident laser light is transmitted by the first polarizer and split by the second one, which also acts as the splitter for a balanced homodyne detector. A rotation of the polarization between the two polarizers can be detected with quantum-limited sensitivity (e.g., ±1 μrad). The squeezed light entering the other port of the interferometer is produced using a χ2 crystal (KTP) in an optical cavity, pumped by a frequency-doubled cw ring Nd:YAG laser. The interferometer sensitivity can thus be increased by a factor depending on the degree of squeezing achieved and on the detector quantum efficiency. Sensitivity increases by factors between 2 and 3 are predicted, and current performance is described.
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.
Squeezed states of light are minimum uncertainty states for which the mean square fluctuations in phase and in quadrature with respect to a reference signal are unequal. Among other interesting properties, they provide improved sensitivity of optical interferometric phase measurements. To understand this potential, one must note that quantum theory imposes measurement uncertainty only on a pair of noncommuting variables; the measurement of any one quantum observable could be done with no uncertainty.>
Introducing squeezed states of light into interferometers can increase the phase sensitivity of the device beyond the standard quantum limit (SQL). We discuss an SU(1,1) interferometer, where nonlinear optical elements replace the beam splitters in a Mach-Zehnder interferometer. A two-mode squeezed state of light is generated inside of such an interferometer. We talk about the phase sensitivities of an SU(1,1) interferometer with different detection schemes and their improvement over the SQL. We also discuss the concept of an optimal detection scheme for phase measurement in an interferometer. We describe a modification of the SU(1,1) interferometer which reduces the experimental complexities while giving the same phase sensitivity. We call the design a truncated SU(1,1) interferometer. We show our experimental results of 4 dB improvement in phase sensitivity over the SQL using a truncated SU(1,1) interferometer. We also compare the theoretical sensitivities of vacuum-seeded configurations of a conventional and a truncated SU(1,1) interferometer, and show our experimental results for the phase sensitivity of the truncated version. We explain the dependence of phase sensitivity on the measurement of squeezing. We talk about the methods to improve the measurement of squeezing in a 4-wave mixing experiment, and our efforts in implementing them. Finally, we mention our progress in measuring a big phase shift using an adaptive algorithm in the truncated SU(1,1) interferometer, and discuss the technicalities involved in big phase measurements.