Progress on a Tactical Ytterbium Microwave Ion Clock

Xianli Zhang, Jay Noble, Jonathan Tallant, Hyunwook Park, Michelle Nguyen, Jackie Ellett, Dan Boschen, Mike Silveira, Cody Dutra, Luan Vo, Anders Herrmann, Kevin Wellwood, Armando Martins, K. Richard Overstreet

Published Feb 15, 2023• 3 citations
Publisher

Abstract

Stable and accurate timekeeping is essential in today’s commercial and military applications. For decades, the 5071A Cesium beam clock has been the mainstay for long-term holdover in strategic applications for its unmatched performance. However, is too large, power hungry and cumbersome for most mobile platforms. To enable improved performance in lower size, weight and power applications, a new physics solution is required over traditional clock technology. In this paper we will present our Ytterbium microwave ion clock progress as a small form factor, high performance clock for use in military and commercial applications where portability is critical. Our device targets maximum performance improvement over traditional methods while minimizing technical risk, leveraging existing manufacturing, and targeting the lowest possible size, power and cost. The Physics Package includes a linear quadrupole trap, an electron gun (e-gun) ionizer, a passive getter pump and a Yb oven. We use electron impact ionization to load Ytterbium-171 ions which are cooled down to room temperature using buffer gas. Interaction-time limited Rabi spectroscopy using microwave radiation at 12.6 GHz is performed. The resulting microwave Rabi linewidth is used for closed-loop clock operation. Concurrent work is underway to develop a 369 nm Distributed Bragg Reflector laser which is essential for robust operation of the clock. We will discuss the specifications, the detailed design of our Ytterbium Microwave Ion Clock, the first assembled Physics Package and related preliminary test results.

DOI
10.33012/2023.18685

Related papers

Physics package validation and system integration for a low-SWaP, portable cold multi-ytterbium ion 12.6 GHz microwave clock

M. A. Trigatzis, Ulas Sabahattin Gokay, Martin Knapp +6 more

Abstract Compact atomic clocks provide the stable, traceable timing required for 5G/6G telecom networks, for resilient operation of critical infrastructure including power grids, data centres and financial systems, and for maintaining accurate synchronisation during GNSS interruptions or outages. Microwave clocks based on caesium beam tubes have been the industry-standard rack-mounted clock for many years but are now outperformed in short-to-midterm instability by emerging technologies. Vapour cell clocks suffer from long-term drift which must be calibrated out periodically and on startup. This limits their use for long-term holdover and in applications where the device needs to operate after a cold start. Additionally, optical clocks require a narrow-linewidth clock laser and optical frequency comb. The ytterbium ion microwave clock developed at the National Physical Laboratory (NPL) does not require these subsystems and combines this relative simplicity with the benefits of laser cooling (long-term stability, accuracy). In this paper, we describe an ion trap physics package design where its functionality has been evaluated in a benchtop clock and forms the basis of a new design for a compact, transportable clock. We describe the operation and performance of the benchtop clock, demonstrating a short-term fractional frequency instability of 1.4 × 10 − 12 /√τ. The design for a new transportable clock based on this new physics package is detailed, as are the validation tests of other key subsystems.

•Jun 18, 2026•0 citations

Subsystems and design for a transportable cold ion microwave clock

M. A. Trigatzis, Ulas Sabahattin Gokay, Martin Knapp +6 more

High performance transportable microwave atomic clocks are enablers for resilient GNSS-free timescales. We present progress towards a transportable laser-cooled ytterbium ion microwave clock. This system incorporates our recently developed multi-ion trap chamber and redesigned electronics and optics systems, offering reductions in size, weight and power, with improved performance over our previous system. The benchtop prototype version of this clock uses the new physics package design and reaches a short-term instability of 1.2 × 10−12/√τ. We present the transportable clock design as well as subsystem test results, which so far indicate that a similar performance to the benchtop version is achievable in a 3U rack-mounted package.

IET conference proceedings.•Aug 1, 2025•0 citations

Miniature microwave frequency standard with trapped 171Yb+

Yuan‐Yu Jau, Peter D. D. Schwindt, Adrian L. Casias +12 more

We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations

A Portable Microwave Clock Using Laser-Cooled Trapped 171Yb+Ions

Sean Mulholland, S. Donnellan, G. P. Barwood +7 more

A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2018•2 citations

Development of (Miniaturized) Trapped Yb Ion Clocks.

Peter D. D. Schwindt

Outline • Introduction• Why trapped ions for miniaturization?• Miniaturized vacuum package: 1 cm 3 • Pulsed-mode ion clock performance • F-state trapping • Current focus: microwave optical double resonance continuous operation • Alternative ion clock: Alkali Mediated Atomic Clock • Conclusion Miniaturization with Long-Term and Environmental Stability • Achieve Cs Beam Clock performance in a mass and power constrained package • DARPA programs: • IMPACT: improved long-term stability • ACES: improved environmental stability Applications--Excellent timing for: • Rapid GPS acquisition, and GPS denied navigation and timing • Nano/pico (cube) satellites • Pulsed radio and spread spectrum communications Microsemi 5071A Miniature primary frequency standard Approved for Public Release, Distribution Unlimited Critical Elements of the 171 Yb + Clock Trap Electrodes Ions Yb Source Vacuum Package Control and Power Electronics Local Oscillator Magnetic Shield and Coil Repump (935 nm) Optical Pumping/ State Detection Laser (369 nm) Beam Combiner Fluorescence Collection Lens Fluorescence Detector Photo Multiplier Tube (PMT) Ionization UV Light

•Dec 12, 2018•0 citations

Development of a portable laser-cooled ytterbium ion microwave atomic clock

Sean Mulholland

Portable microwave clocks that incorporate laser cooling promise to bring significantly improved performance compared to commercially available microwave clocks that are based on thermal atoms. This thesis reports on the development of a portable, laser-cooled ytterbium-171 trapped-ion microwave frequency standard from design to testing.

•Jan 1, 2019•1 citation
Stable and accurate timekeeping is essential in today’s commercial and military applications. For decades, the 5071A Cesium beam clock has been the mainstay for long-term holdover in strategic applications for its unmatched performance. However, is too large, power hungry and cumbersome for most mobile platforms. To enable improved performance in lower size, weight and power applications, a new physics solution is required over traditional clock technology. In this paper we will present our Ytterbium microwave ion clock progress as a small form factor, high performance clock for use in military and commercial applications where portability is critical. Our device targets maximum performance improvement over traditional methods while minimizing technical risk, leveraging existing manufacturing, and targeting the lowest possible size, power and cost. The Physics Package includes a linear quadrupole trap, an electron gun (e-gun) ionizer, a passive getter pump and a Yb oven. We use electron impact ionization to load Ytterbium-171 ions which are cooled down to room temperature using buffer gas. Interaction-time limited Rabi spectroscopy using microwave radiation at 12.6 GHz is performed. The resulting microwave Rabi linewidth is used for closed-loop clock operation. Concurrent work is underway to develop a 369 nm Distributed Bragg Reflector laser which is essential for robust operation of the clock. We will discuss the specifications, the detailed design of our Ytterbium Microwave Ion Clock, the first assembled Physics Package and related preliminary test results.
Abstract Compact atomic clocks provide the stable, traceable timing required for 5G/6G telecom networks, for resilient operation of critical infrastructure including power grids, data centres and financial systems, and for maintaining accurate synchronisation during GNSS interruptions or outages. Microwave clocks based on caesium beam tubes have been the industry-standard rack-mounted clock for many years but are now outperformed in short-to-midterm instability by emerging technologies. Vapour cell clocks suffer from long-term drift which must be calibrated out periodically and on startup. This limits their use for long-term holdover and in applications where the device needs to operate after a cold start. Additionally, optical clocks require a narrow-linewidth clock laser and optical frequency comb. The ytterbium ion microwave clock developed at the National Physical Laboratory (NPL) does not require these subsystems and combines this relative simplicity with the benefits of laser cooling (long-term stability, accuracy). In this paper, we describe an ion trap physics package design where its functionality has been evaluated in a benchtop clock and forms the basis of a new design for a compact, transportable clock. We describe the operation and performance of the benchtop clock, demonstrating a short-term fractional frequency instability of 1.4 × 10 − 12 /√τ. The design for a new transportable clock based on this new physics package is detailed, as are the validation tests of other key subsystems.
High performance transportable microwave atomic clocks are enablers for resilient GNSS-free timescales. We present progress towards a transportable laser-cooled ytterbium ion microwave clock. This system incorporates our recently developed multi-ion trap chamber and redesigned electronics and optics systems, offering reductions in size, weight and power, with improved performance over our previous system. The benchtop prototype version of this clock uses the new physics package design and reaches a short-term instability of 1.2 × 10−12/√τ. We present the transportable clock design as well as subsystem test results, which so far indicate that a similar performance to the benchtop version is achievable in a 3U rack-mounted package.
We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].
A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.
Outline • Introduction• Why trapped ions for miniaturization?• Miniaturized vacuum package: 1 cm 3 • Pulsed-mode ion clock performance • F-state trapping • Current focus: microwave optical double resonance continuous operation • Alternative ion clock: Alkali Mediated Atomic Clock • Conclusion Miniaturization with Long-Term and Environmental Stability • Achieve Cs Beam Clock performance in a mass and power constrained package • DARPA programs: • IMPACT: improved long-term stability • ACES: improved environmental stability Applications--Excellent timing for: • Rapid GPS acquisition, and GPS denied navigation and timing • Nano/pico (cube) satellites • Pulsed radio and spread spectrum communications Microsemi 5071A Miniature primary frequency standard Approved for Public Release, Distribution Unlimited Critical Elements of the 171 Yb + Clock Trap Electrodes Ions Yb Source Vacuum Package Control and Power Electronics Local Oscillator Magnetic Shield and Coil Repump (935 nm) Optical Pumping/ State Detection Laser (369 nm) Beam Combiner Fluorescence Collection Lens Fluorescence Detector Photo Multiplier Tube (PMT) Ionization UV Light