Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics & Laser Technology

High-sensitivity pump–probe atomic magnetometer based on single fiber-coupled

Binbin Zhao, Junjian Tang, Hongying Yang, Lin Li, Yaohua Zhang, Ying Liu, Yueyang Zhai

Published Dec 13, 2022• 24 citations
Publisher
DOI
10.1016/j.optlastec.2022.109025

Related papers

High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer

Yuhao Wang, Ying Liu, Ziqian Yue +4 more

Optics and Lasers in Engineering•Feb 10, 2025•1 citation

A two-color pump probe atomic magnetometer for magnetoencephalography

Cort Johnson, Peter D. D. Schwindt

In recent years, atomic magnetometers (AMs) have demonstrated sub-femtotesla sensitivities and have emerged as potential replacements for superconducting quantum interference devices (SQUIDs). In an AM, a circularly polarized pump laser aligns the electron spins in a cloud of alkali metal vapor. Changes occur in the optical properties of the vapor when its collective moment interacts with an external magnetic field, resulting in a measurable polarization rotation of a linearly polarized probe beam. We present a unique pump/probe scheme in which a pump beam tuned to the87Rb D1 line (795 nm) and a probe beam tuned to the D2 line (780 nm) share a single optical axis. A dichroic waveplate is used to circularly polarize the pump beam while leaving the probe beam linearly polarized. Based upon this scheme, we have developed a small profile, fiber-coupled AM. By independently optimizing pump/probe power and detuning, we are able to achieve intrinsic single-channel sensitivity of <; 5 fT/√Hz, which is suitable for demanding applications such as magnetoencephalography (MEG). Furthermore, through straightforward adaptations of the current design, it should be possible to create dense, reconfigurable arrays of AMs for whole-head MEG.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•17 citations

Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

IEEE Transactions on Magnetics•Oct 1, 2011•53 citations

Progress in high sensitive atomic magnetometers

Guobin Liu, Xian-Ping Sun, 顾思洪 +2 more

Wuli•Jan 1, 2012•1 citation

A laser pump-re-pump atomic magnetometer

杨爱林, 杨国卿, 蔡勋明 +2 more

中国物理B:英文版•Jan 1, 2013•0 citations

Robust, High-speed, All-Optical Atomic Magnetometer

Higbie, J M, Corsini, E, Budker, D

A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding $1\\khz$. Pump and probe are delivered by optical fiber, facilitating miniaturization and modularization. The magnetometer has been operated both with vertical-cavity surface-emitting lasers (VCSELs), which are well suited to portable applications, and with conventional edge-emitting diode lasers. A sensitivity of around $3 {\\rm nG}$ is achieved for a measurement time of $1\\s$.

•Sep 6, 2006•34 citations
In recent years, atomic magnetometers (AMs) have demonstrated sub-femtotesla sensitivities and have emerged as potential replacements for superconducting quantum interference devices (SQUIDs). In an AM, a circularly polarized pump laser aligns the electron spins in a cloud of alkali metal vapor. Changes occur in the optical properties of the vapor when its collective moment interacts with an external magnetic field, resulting in a measurable polarization rotation of a linearly polarized probe beam. We present a unique pump/probe scheme in which a pump beam tuned to the87Rb D1 line (795 nm) and a probe beam tuned to the D2 line (780 nm) share a single optical axis. A dichroic waveplate is used to circularly polarize the pump beam while leaving the probe beam linearly polarized. Based upon this scheme, we have developed a small profile, fiber-coupled AM. By independently optimizing pump/probe power and detuning, we are able to achieve intrinsic single-channel sensitivity of <; 5 fT/√Hz, which is suitable for demanding applications such as magnetoencephalography (MEG). Furthermore, through straightforward adaptations of the current design, it should be possible to create dense, reconfigurable arrays of AMs for whole-head MEG.
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.
A self-oscillating magnetometer based on the nonlinear magneto-optical rotation effect with separate modulated pump and unmodulated probe beams is demonstrated. This device possesses a bandwidth exceeding 1khz1\\khz1khz. Pump and probe are delivered by optical fiber, facilitating miniaturization and modularization. The magnetometer has been operated both with vertical-cavity surface-emitting lasers (VCSELs), which are well suited to portable applications, and with conventional edge-emitting diode lasers. A sensitivity of around 3rmnG3 {\\rm nG}3rmnG is achieved for a measurement time of 1s1\\s1s.