Optics Express

In-situ measurement and cancellation of the light-shift in fiber-coupled atomic magnetometers

Binbin Zhao, Junjian Tang, Lin Li, Yaohua Zhang, Cao Li, Ying Liu, Yueyang Zhai

Published Nov 8, 2022• 7 citations
Publisher

Abstract

In optical atomic magnetometers (AMs), the light-shift caused by the circularly polarized pumping beam have a significant impact on the response and is also one of the non-negligible sources of the noise. In this paper, we develop a novel method whereby utilizing the symmetry of the frequency response in an AM to measure and cancel the light-shift. Furthermore, we theoretically analyze and experimentally verify a rapid method of magnetic field compensation and the approach is convenient to measure and cancel of the light-shift. Moreover, the influence of intensity and frequency of the pumping beam is also investigated. The proposed method of in - situ measurement and cancellation of light-shift will be particularly profitable to other optical systems based on AMs.

DOI
10.1364/oe.476113

Related papers

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•2 citations

Precise Measurement of Magnetic Shielding Residual Field and Light Shift Based on 87Rb Atomic Magnetometer

Binbin Zhao, Junjian Tang, Lin Li +2 more

Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•4 citations

Measurement and cancellation of light shift in optically pumped magnetometers

Rujie Li, Wei Quan, Wenfeng Fan +1 more

Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.

Europhysics Letters (EPL)•Mar 1, 2018•13 citations

Single-Beam Optically Pumped Atomic Magnetometer With Suppression of Light Shift Based on Space-Division Multiplexing Light

Rongtong Zhu, Jianli Li, Shuo Sun +4 more

Single-beam optically pumped atomic magnetometers (OPAMs) represent promising candidates for applications in geomagnetic field monitoring, biomedicine, and various other precision sensing domains owing to their exceptional sensitivity, high measurement accuracy, and cost-effectiveness. However, in orientation-based OPAMs utilizing circularly polarized light (CPL) pumping, the off-resonant light introduces light shift. The light shift acts as an additional magnetic field, reducing the measurement accuracy of OPAMs. Moreover, the dependence of the light shift on light intensity and frequency facilitates the conversion of light noise into magnetic noise, thereby degrading the sensitivity of OPAMs. In this study, we propose an optical pumping scheme based on space division multiplexing light (SDML) to suppress the light shift in OPAM. The approach employs two orthogonally polarized linearly polarized beams with a controlled phase difference to generate a spatially periodic distribution of left- and right-handed CPL. Optical pumping with the SDML induces oppositely directed light shifts in distinct spatial regions that effectively cancel each other. Finally, it is verified by experiments that the light shift is greatly suppressed based on SDML. Under detuned SDML pumping, both the light shift and light intensity noise are suppressed by over 50%, while maintaining a sensitivity comparable to that achieved with conventional CPL pumping. The proposed method demonstrates significant potential for magnetometers in light-noise-prone environments, and it can be generalized to other orientation-based magnetometers that rely on CPL pumping.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•1 citation

Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer

Ze Cai, Lihong Duan, Kai Zhang +5 more

Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.

IEEE Sensors Journal•Nov 18, 2024•3 citations

Light-shift suppression in an optically pumped magnetometer via dual-frequency optical pumping

Huanyu Zhou, J Q Li, Yi Zhang +5 more

The light shift represents a major source of measurement error and system noise in optically pumped atomic magnetometers (OPAMs). Tuning the laser frequency to a specific value is a common and effective approach to suppressing light shift in many optical-pumping systems. However, when this method is applied to OPAMs, a significant issue arises: at the zero-light-shift frequency, the magnetometer’s sensitivity decreases markedly. Consequently, it is not possible to optimize simultaneously both the measurement accuracy affected by the light shift and the overall sensitivity of the magnetometer. To address this contradiction, the underlying mechanism was analyzed using the theory of light absorption and the principles governing light–atom interactions, leading to the proposal of a dual-frequency optical-pumping scheme. Experimental results demonstrate that this approach can suppress the light shift by more than 95% while maintaining the optimal sensitivity of the OPAM. The proposed dual-frequency scheme can also be extended to other circularly polarized optical-pumping systems, thereby facilitating both the enhancement of OPAM performance and its practical deployment in real-world applications.

Advanced Photonics Nexus•Jun 19, 2026•0 citations
In optical atomic magnetometers (AMs), the light-shift caused by the circularly polarized pumping beam have a significant impact on the response and is also one of the non-negligible sources of the noise. In this paper, we develop a novel method whereby utilizing the symmetry of the frequency response in an AM to measure and cancel the light-shift. Furthermore, we theoretically analyze and experimentally verify a rapid method of magnetic field compensation and the approach is convenient to measure and cancel of the light-shift. Moreover, the influence of intensity and frequency of the pumping beam is also investigated. The proposed method of in - situ measurement and cancellation of light-shift will be particularly profitable to other optical systems based on AMs.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.
Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.
Light shift arising from the circularly polarized pump beam in atomic magnetometers can induce an undesired magnetic response, and thus affect their accuracy. Here, the light shift and the corresponding cross-talk effect in the magnetometer have been investigated, and a scheme with an additional off-resonant pump beam with an appropriate polarization and intensity has been proposed to effectively reject the light shift. And the experimental results reproduce the expected behavior. This scheme provides a powerful tool to reject the light shift in optical pumping systems, in particular, the hybrid optically pumped systems.
Single-beam optically pumped atomic magnetometers (OPAMs) represent promising candidates for applications in geomagnetic field monitoring, biomedicine, and various other precision sensing domains owing to their exceptional sensitivity, high measurement accuracy, and cost-effectiveness. However, in orientation-based OPAMs utilizing circularly polarized light (CPL) pumping, the off-resonant light introduces light shift. The light shift acts as an additional magnetic field, reducing the measurement accuracy of OPAMs. Moreover, the dependence of the light shift on light intensity and frequency facilitates the conversion of light noise into magnetic noise, thereby degrading the sensitivity of OPAMs. In this study, we propose an optical pumping scheme based on space division multiplexing light (SDML) to suppress the light shift in OPAM. The approach employs two orthogonally polarized linearly polarized beams with a controlled phase difference to generate a spatially periodic distribution of left- and right-handed CPL. Optical pumping with the SDML induces oppositely directed light shifts in distinct spatial regions that effectively cancel each other. Finally, it is verified by experiments that the light shift is greatly suppressed based on SDML. Under detuned SDML pumping, both the light shift and light intensity noise are suppressed by over 50%, while maintaining a sensitivity comparable to that achieved with conventional CPL pumping. The proposed method demonstrates significant potential for magnetometers in light-noise-prone environments, and it can be generalized to other orientation-based magnetometers that rely on CPL pumping.
Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.
The light shift represents a major source of measurement error and system noise in optically pumped atomic magnetometers (OPAMs). Tuning the laser frequency to a specific value is a common and effective approach to suppressing light shift in many optical-pumping systems. However, when this method is applied to OPAMs, a significant issue arises: at the zero-light-shift frequency, the magnetometer’s sensitivity decreases markedly. Consequently, it is not possible to optimize simultaneously both the measurement accuracy affected by the light shift and the overall sensitivity of the magnetometer. To address this contradiction, the underlying mechanism was analyzed using the theory of light absorption and the principles governing light–atom interactions, leading to the proposal of a dual-frequency optical-pumping scheme. Experimental results demonstrate that this approach can suppress the light shift by more than 95% while maintaining the optimal sensitivity of the OPAM. The proposed dual-frequency scheme can also be extended to other circularly polarized optical-pumping systems, thereby facilitating both the enhancement of OPAM performance and its practical deployment in real-world applications.