Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer series in chemical physics

Diffractive optics-based heterodyne detected three-pulse photon echo

Jennifer P. Ogilvie, M. L. Cowan, Michael R. Armstrong, Andrea M. Nagy, R. J. Dwayne Miller

Published Jan 1, 2003• 1 citation
Publisher
DOI
10.1007/978-3-642-59319-2_177

Related papers

Heterodyne-detected accumulated photon echo in CdSe quantum dots

K Takemoto, Byung‐Ryool Hyun, Yasuaki Masumoto

Solid State Communications•May 1, 2000•24 citations

Three-pulse photon echo peak shift in optically dense samples

Niklas Christensson, Benjamin Dietzek, Torbjoern Pascher +2 more

Chemical Physics Letters•Apr 8, 2008•16 citations

Diffractive optics-based heterodyne detected three-pulse photon echo

Jennifer P. Ogilvie, Michael R. Armstrong, Andrea M. Nagy +1 more

A novel diffractive optics-based method for performing three pulse photon echoes is demonstrated and extends the inherent passive phase stabilization of diffractive optics to this class of experiments for complete recovery of the signal field.

International Conference on Ultrafast Phenomena•Jan 1, 2002•6 citations

Three-pulse spherical-wave photon echo

S. O. Elyutin, Sergey M. Zakharov, Edward A. Manykin

Optics and Spectroscopy•Feb 1, 1986•0 citations

Two-dimensional spectroscopy using diffractive optics based phased-locked photon echoes

M. L. Cowan, Jennifer P. Ogilvie, R. J. Dwayne Miller

Chemical Physics Letters•Feb 10, 2004•336 citations

Optical Resonance Imaging: An Optical Analog to MRI with Subdiffraction-Limited Capabilities

Marco A. Allodi, Peter D. Dahlberg, Richard J. Mazuski +3 more

We propose here optical resonance imaging (ORI), a direct optical analog to magnetic resonance imaging (MRI). The proposed pulse sequence for ORI maps space to time and recovers an image from a heterodyne-detected third-order nonlinear photon echo measurement. As opposed to traditional photon echo measurements, the third pulse in the ORI pulse sequence has significant pulse-front tilt that acts as a temporal gradient. This gradient couples space to time by stimulating the emission of a photon echo signal from different lateral spatial locations of a sample at different times, providing a widefield ultrafast microscopy. We circumvent the diffraction limit of the optics by mapping the lateral spatial coordinate of the sample with the emission time of the signal, which can be measured to high precision using interferometric heterodyne detection. This technique is thus an optical analog of MRI, where magnetic-field gradients are used to localize the spin–echo emission to a point below the diffraction limit of the radio frequency wave used. We calculate the expected ORI signal using 15 fs pulses and 87° of pulse-front tilt, collected using f /2 optics, and find a two-point resolution of 275 nm using 800 nm light that satisfies the Rayleigh criterion. We also derive a general equation for resolution in optical resonance imaging that indicates that there is a possibility of superresolution imaging using this technique. The photon echo sequence also enables spectroscopic determination of the input and output energy. The technique thus correlates the input energy with the final position and energy of the exciton.

ACS Photonics•Nov 8, 2016•4 citations
We propose here optical resonance imaging (ORI), a direct optical analog to magnetic resonance imaging (MRI). The proposed pulse sequence for ORI maps space to time and recovers an image from a heterodyne-detected third-order nonlinear photon echo measurement. As opposed to traditional photon echo measurements, the third pulse in the ORI pulse sequence has significant pulse-front tilt that acts as a temporal gradient. This gradient couples space to time by stimulating the emission of a photon echo signal from different lateral spatial locations of a sample at different times, providing a widefield ultrafast microscopy. We circumvent the diffraction limit of the optics by mapping the lateral spatial coordinate of the sample with the emission time of the signal, which can be measured to high precision using interferometric heterodyne detection. This technique is thus an optical analog of MRI, where magnetic-field gradients are used to localize the spin–echo emission to a point below the diffraction limit of the radio frequency wave used. We calculate the expected ORI signal using 15 fs pulses and 87° of pulse-front tilt, collected using f /2 optics, and find a two-point resolution of 275 nm using 800 nm light that satisfies the Rayleigh criterion. We also derive a general equation for resolution in optical resonance imaging that indicates that there is a possibility of superresolution imaging using this technique. The photon echo sequence also enables spectroscopic determination of the input and output energy. The technique thus correlates the input energy with the final position and energy of the exciton.