Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cambridge University Press eBooks

Quantum Refrigerators and the Third Law

Gershon Kurizki, Abraham G. Kofman

Published Dec 23, 2021• 0 citations
Publisher
DOI
10.1017/9781316798454.024

Related papers

Thermodynamics’ third law and quantum phase transitions

Michael Kruse, H. G. Miller, Angel Ricardo Plastino +1 more

Physica A Statistical Mechanics and its Applications•Mar 16, 2010•1 citation

Quantum engines and refrigerators

Loris Maria Cangemi, Chitrak Bhadra, Amikam Levy

arXiv:2302.00726•Physics Reports•Aug 5, 2024•92 citations

Restoration of the Third Law of Thermodynamics in a Quantum Refrigerator Model

Vegard B. Sørdal

1 entropy and the laws of thermodynamics 1 1.1 Entropy 2 1.1.1Classical and Statistical Entropy 4 1.1.2Aspects of Entropy 6 1.2 The 0th Law 7 1.3The 1st Law 7 1.4The 2nd Law 8 2 the third law 11 2.1 Consequences of the Third Law 12 2.2 Helium and the Third Law 14 2.3 Non-Equilibrium Degrees of Freedom 15 2.4 The Unattainability of Absolute Zero 19 3 violations of the laws of thermodynamics 23 3.1 The Second Law 23 3.1.1Fluctuations 24 3.2 The Third Law 26 4 the boson driven refrigerator 29 4.1 Introduction of the Refrigerator Model 29 4.2 Discussion 30 4.3 Non-Equilibrium Systems and Thermodynamics 36 4.4 Objective 37 5 non-equilibrium thermodynamics 39 5.1 The Stochastic Master Equation 40 5.2 Local Detailed Balance 41 5.3 The Stochastic Laws of Thermodynamics 42 5.3.1 The First Law 42 5.3.2The Second Law 43 5.4 Tight Coupling and Efficiency 45 6 boson powered refrigeration 49 6.1 Particle Currents 49 6.2 Heat Transport and Effieciency 52 6.3 Cooling power in the Limit of Absolute Zero 56 7 numerically optimized cooling 59 7.1 Conditions for Optimized Cooling 59 7.2 The Very Low Temperature Regime 63 8 finite energy level spacing 67 8.1 Dependency on δ and ∆ 73 8.2 Maximized Cooling Power 75 8.3 Higher Order Transitions 79 VII VIII contents 8.4 Heat Capacity of the Discrete Model 80 8.5 The Unattainability of Absolute Zero 82 9 summary 85 9.1 Summary and Conclusions 85 9.2 Discussion 86 9.3 Recommendations for Further Work 87 a appendix 89 a.1 C++ Source Code for the Continuous Model 89 a.2 C++ Source Code for the Discrete Model 96

•Jan 1, 2015•0 citations

The quantum refrigerator: The quest for absolute zero

Y. Rezek, P. Salamon, K. H. Hoffmann +1 more

The emergence of the laws of thermodynamics from the laws of quantum mechanics is an unresolved issue. The generation of the third law of thermodynamics from quantum dynamics is analysed. The scaling of the optimal cooling power of a reciprocating quantum refrigerator is sought as a function of the cold bath temperature as T c →0. The working medium consists of noninteracting particles in a harmonic potential. Two closed-form solutions of the refrigeration cycle are analyzed, and compared to a numerical optimization scheme, focusing on cooling toward zero temperature. The optimal cycle is characterized by linear relations between the heat extracted from the cold bath, the energy level spacing of the working medium and the temperature. The scaling of the optimal cooling rate is found to be proportional to T c 3/2 giving a dynamical interpretation to the third law of thermodynamics.

arXiv:0808.0229•Europhysics Letters (EPL)•Feb 1, 2009•101 citations

Autonomous quantum absorption refrigerators

Étienne Jussiau, Sreenath K. Manikandan, Andrew N. Jordan

Bulletin of the American Physical Society•Mar 18, 2021•0 citations

Third law of thermodynamics and quantum-statistical systems

Miodrag L. Kulić, Davidović-Ristovski, G. S., Ristovski, Lj. M.

•Jan 1, 1980•0 citations
1 entropy and the laws of thermodynamics 1 1.1 Entropy 2 1.1.1Classical and Statistical Entropy 4 1.1.2Aspects of Entropy 6 1.2 The 0th Law 7 1.3The 1st Law 7 1.4The 2nd Law 8 2 the third law 11 2.1 Consequences of the Third Law 12 2.2 Helium and the Third Law 14 2.3 Non-Equilibrium Degrees of Freedom 15 2.4 The Unattainability of Absolute Zero 19 3 violations of the laws of thermodynamics 23 3.1 The Second Law 23 3.1.1Fluctuations 24 3.2 The Third Law 26 4 the boson driven refrigerator 29 4.1 Introduction of the Refrigerator Model 29 4.2 Discussion 30 4.3 Non-Equilibrium Systems and Thermodynamics 36 4.4 Objective 37 5 non-equilibrium thermodynamics 39 5.1 The Stochastic Master Equation 40 5.2 Local Detailed Balance 41 5.3 The Stochastic Laws of Thermodynamics 42 5.3.1 The First Law 42 5.3.2The Second Law 43 5.4 Tight Coupling and Efficiency 45 6 boson powered refrigeration 49 6.1 Particle Currents 49 6.2 Heat Transport and Effieciency 52 6.3 Cooling power in the Limit of Absolute Zero 56 7 numerically optimized cooling 59 7.1 Conditions for Optimized Cooling 59 7.2 The Very Low Temperature Regime 63 8 finite energy level spacing 67 8.1 Dependency on δ and ∆ 73 8.2 Maximized Cooling Power 75 8.3 Higher Order Transitions 79 VII VIII contents 8.4 Heat Capacity of the Discrete Model 80 8.5 The Unattainability of Absolute Zero 82 9 summary 85 9.1 Summary and Conclusions 85 9.2 Discussion 86 9.3 Recommendations for Further Work 87 a appendix 89 a.1 C++ Source Code for the Continuous Model 89 a.2 C++ Source Code for the Discrete Model 96
The emergence of the laws of thermodynamics from the laws of quantum mechanics is an unresolved issue. The generation of the third law of thermodynamics from quantum dynamics is analysed. The scaling of the optimal cooling power of a reciprocating quantum refrigerator is sought as a function of the cold bath temperature as T c →0. The working medium consists of noninteracting particles in a harmonic potential. Two closed-form solutions of the refrigeration cycle are analyzed, and compared to a numerical optimization scheme, focusing on cooling toward zero temperature. The optimal cycle is characterized by linear relations between the heat extracted from the cold bath, the energy level spacing of the working medium and the temperature. The scaling of the optimal cooling rate is found to be proportional to T c 3/2 giving a dynamical interpretation to the third law of thermodynamics.