High precision phase estimation is at the core of modern physics and practical applications. We investigate a method for high precision phase estimation via inserting a reference state which enables weak measurement technique to be used in wide dynamic range. A reference phase is introduced artificially to offset the time delay between preselection state and reference state. The sensitivity of measured phase and the linear dynamic range are controllable by adjusting reference phase. Moreover, an arbitrary postselection in measurement is applicable by choosing appropriate reference phase. This method has merits of controllable sensitivity and wide dynamic range, which shows great potential practical applications in high precision phase measurement.
High precision phase estimation is at the core of modern physics and practical applications. We investigate a method for high precision phase estimation via inserting a reference state which enables weak measurement technique to be used in wide dynamic range. A reference phase is introduced artificially to offset the time delay between preselection state and reference state. The sensitivity of measured phase and the linear dynamic range are controllable by adjusting reference phase. Moreover, an arbitrary postselection in measurement is applicable by choosing appropriate reference phase. This method has merits of controllable sensitivity and wide dynamic range, which shows great potential practical applications in high precision phase measurement.
The real-time estimation of a time-varying phase is of great importance in several fields. In order to estimate a time-varying phase with high precision and sensitivity, we propose and experimentally demonstrate an adaptive phase estimation method via weak value amplification by splitting the light into sensing path and monitoring path. In the proposed method, the phase shift can be amplified, an adjustable sensitivity and linear dynamic range can be obtained through the insertion of the reference phase, and a full-range phase estimation could be realized via an appropriate adjustment strategy. Furthermore, detectors with a higher resolution could be selected to detect weak signal by the adjustment of attenuation. Potentially, the phase estimation precision of about 10−8 rad could be achieved with the available equipment.
We theoretically propose and experimentally demonstrate a modulated weak measurement scheme that permits a precise estimation of the extended phase shift. By choosing the frequency and the total post-selected light intensity as the input and output meter variables, respectively, a linear weak measurement model is established that is especially applicable to precise phase estimation. By performing a time-delay-dependent modulation strategy based on the feedback modulation of the experimental outcome, both the high phase-sensitivity and measurement precision can be retained. We have achieved a precision at the order of ∼10−5 rad that can be effectively retained with an increase in the measured phase.
High-precision temperature measurement with adjustable operating range is investigated and experimentally demonstrated based on weak measurement in the frequency domain. The operating range of measurement is precisely modulated by introducing a dynamic extra time delay to the post-selection pumped by a femtosecond laser. By choosing appropriate nonlinear materials and the attenuation, the resolution of the optimized extra time delay can be improved by two orders of magnitude over that of a traditional phase delay compensator. Considering the influence of noise in the experiment, the highest precision of 8.03 × 10 −7 °C can be achieved by using a currently available spectrometer. Moreover, the average sensitivity can reach to 38 nm/°C. Taking advantage of the high precision and adjustable operating range, the proposed method has great potential applications in high-precision temperature measurements.
An adaptive correction algorithm is demonstrated based on weak measurement, which introduces a feedback and an additional interaction to the system and can dynamically adjust the operating point in accordance with the condition of the estimated phase change. Two schemes, fast adaptive correction and slow adaptive correction, are proposed for different conditions of the modulation device. Fast adaptive correction scheme can realize a real-time correction and maintain the high sensitivity. Slow adaptive correction scheme, as a supplement, can correct the distortion of the measured parameter by changing the measuring period. These two schemes are useful for high precision phase estimation with time in modern physics and practical applications, including, but not limited to, timing synchronization, accurate distance measurement, and gravity wave detection. Moreover, we discuss the deviation of the adaptive correction for considering system noise in practical measurement.
In sensing technologies, the efforts for increasing sensitivity are usually at the cost of restraining the dynamic range. Here, we propose a closed-loop-control-based weak-value amplification (WVA) method to address this trade-off problem. Different from the previous adaptive WVA schemes, our method can significantly increase the dynamic range without sacrificing sensitivity, and hence improve the sensing dynamic factor by several orders of magnitude, in principle. Moreover, by employing the small weak value in the feedback process, the phase-modulation uncertainty can be effectively suppressed and provide much higher SNR in practice. Additionally, our approach achieves high-sensitivity detection and high-precision closed-loop control on two distinct dimensions within the same weak-measurement system. Our method can find broad applications on sensing technologies that require both high sensitivity and wide dynamic range, such as the sensing of temperature, magnetic fields, pressure, angular velocity, and so on.
Optical time delays play a pivotal role in modern physics and practical applications. We propose and experimentally validate a weak measurement system with a double-edge filter, which enables the real-time, high-precision estimation of varying time delays, and the effective suppression of technical noise. In the experiment, the postselected probe light is processed by the double-edge filter, which is formed by a pair of fiber Bragg gratings positioned symmetrically about the center frequency of the probe light, and subsequently detected by photodetectors. The experimental results demonstrate a time-delay precision of 1.66 attoseconds (as) and real-time estimation capability. With a postselection angle of ${10}^{\ensuremath{-}3}\phantom{\rule{0.16em}{0ex}}\mathrm{rad}$ and the system operating within the most sensitive linear dynamic range, the precision can be further improved to ${10}^{\ensuremath{-}4}$ as. The approach benefits from its high sensitivity and rapid detection, which shows great potential applications in real-time and high-precision time-delay measurements.