Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

In-Situ Measurement of the Density Ratio of the K-Rb-21Ne Comagnetometer Based on Electron Spin Relaxation Rate

Tian Zhao, Kai Wei, Yueyang Zhai, Chencheng Tang

Published Nov 1, 2021• 1 citation
Publisher

Abstract

Abstract Accurate measurement of alkali metal density ratio in hybrid vapor cells is essential for high sensitivity of comagnetometers. We introduce and investigate a new method of measuring the density ratio based on electron spin-relaxation rate. The Bloch equations including the parameter of density ratio are studied, and the density measurement results show that measurement uncertainty is less than 12%. The advantage of this method is measuring the in-situ density ratio, which is more precise and useful for optimizing sensitivity of comagnetometers by adjusting the density ratio in real time.

DOI
10.1088/1742-6596/2112/1/012010

Related papers

Spin polarization characteristics of hybrid optically pumped comagnetometers with different density ratios

Tian Zhao, Yueyang Zhai, Chang Liu +3 more

We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb- 21 Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.

Optics Express•Jul 5, 2022•17 citations

In-situ measurement of the density ratio of K-Rb hybrid vapor cell using spin-exchange collision mixing of the K and Rb light shifts

Kai Wei, Tian Zhao, Xiujie Fang +3 more

Ne comagnetometer-cells at different temperatures, pump light powers, and mole fractions of K. The method was further verified by the conventional laser-absorption-spectroscopy method. The new approach has the advantage to measure the density ratio of the optically-thick hybrid alkali atoms, while requiring no additional magnetic field necessary for conventional magnetic-field induced Faraday-rotation techniques. It also has the advantage of in-situ measuring the density ratio under exactly the normal operation of the devices, which means that the errors caused by the heating-effect of the strong pump light and the temperature drift during long-term operation can be real-time monitored.

Optics Express•May 22, 2019•29 citations

Density-ratio dependence of spin polarization and spatial homogeneity in hybrid Rb–Cs vapor cells

Ge Jin, Tao shi, Yuxin Chen +2 more

Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.

Journal of Physics D Applied Physics•Apr 21, 2026•1 citation

In-situ measurement of cell temperature by spin-relaxation rate analysis for an atomic magnetometer

Bingquan Zhao, Zhe Qi, Jianlong Wang +5 more

Abstract Alkali-metal vapor cells are the core sensing components of atomic magnetometers. To achieve high-sensitivity magnetic field measurements, the cells require heating and stabilization at high temperatures. Here, we propose an in-situ temperature measurement method for a vapor cell of an atomic magnetometer based on spin-relaxation analysis. This technique establishes a direct functional correlation between the cell temperature and the spin-relaxation rate under low pumping power conditions. Experimental validation within the temperature range of 90 °C–130 °C confirms the accuracy of this approach. We further investigate the effects of magnetic fields on measurement precision and demonstrate the long-term, high-precision capabilities of temperature detection. This non-invasive technique presents a critical advantage for precise thermal optimization of atomic magnetometers.

Chinese Physics B•Sep 17, 2025•0 citations

In situ determination of alkali metal density using phase-frequency analysis on atomic magnetometers

Han Yao, Hong Zhang, Danyue Ma +2 more

Abstract The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.

Measurement Science and Technology•Jul 6, 2018•8 citations

Real-time nondemolition measurement method for alkali vapor density and its application in a spin-exchange relaxation-free co-magnetometer

Ruigang Wang, Feng Li, Zehua Liu +3 more

This study presents a novel method for measuring the number density of K in K-Rb hybrid vapor cells using circularly polarized pump light on polarized alkali metal atoms. This proposed method eliminates the need for additional devices such as absorption spectroscopy, Faraday rotation, or resistance temperature detector technology. The modeling process involved considering wall loss, scattering loss, atomic absorption loss, and atomic saturation absorption, with experiments designed to identify the relevant parameters. The proposed method is real-time, highly stable, and a quantum nondemolition measurement that does not disrupt the spin-exchange relaxation-free (SERF) regime. Experimental results demonstrate the effectiveness of the proposed method, as the longitudinal electron spin polarization long-term stability increased by 204% and the transversal electron spin polarization long-term stability increased by 44.8%, as evaluated by the Allan variance.

Optics Express•May 23, 2023•15 citations
Abstract Accurate measurement of alkali metal density ratio in hybrid vapor cells is essential for high sensitivity of comagnetometers. We introduce and investigate a new method of measuring the density ratio based on electron spin-relaxation rate. The Bloch equations including the parameter of density ratio are studied, and the density measurement results show that measurement uncertainty is less than 12%. The advantage of this method is measuring the in-situ density ratio, which is more precise and useful for optimizing sensitivity of comagnetometers by adjusting the density ratio in real time.
We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb- 21 Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.
Ne comagnetometer-cells at different temperatures, pump light powers, and mole fractions of K. The method was further verified by the conventional laser-absorption-spectroscopy method. The new approach has the advantage to measure the density ratio of the optically-thick hybrid alkali atoms, while requiring no additional magnetic field necessary for conventional magnetic-field induced Faraday-rotation techniques. It also has the advantage of in-situ measuring the density ratio under exactly the normal operation of the devices, which means that the errors caused by the heating-effect of the strong pump light and the temperature drift during long-term operation can be real-time monitored.
Abstract Hybrid spin-exchange optical pumping (hybrid SEOP) using multiple alkali-metal species is commonly employed to improve the spatial homogeneity of alkali spin polarization in atomic magnetometers and comagnetometers. We investigate the dependence of spin polarization and its spatial homogeneity on the alkali density ratio D r = [ Rb ] / [ Cs ] in Rb–Cs hybrid vapor cells. A series of cells with controlled D r were fabricated and characterized using absolute electron paramagnetic resonance polarimetry at multiple positions along the cell axis. The results show that the density ratio strongly influences both the magnitude and spatial uniformity of alkali polarization through the competition among optical pumping, spin exchange, and spin-destruction processes. An optimal density ratio is observed near D r ≈ 6.59 ± 0.47 , where the polarization reaches its maximum while maintaining high spatial homogeneity (end-to-end ratio ∼89% and RMS homogeneity > 95 % ). Under typical operating conditions, the optimal density ratio lies in the range D r ≈ 4 –10. These results clarify the role of the alkali density ratio in Rb–Cs hybrid SEOP and provide practical guidance for optimizing hybrid vapor cells used in precision atomic magnetometers and comagnetometers.
Abstract Alkali-metal vapor cells are the core sensing components of atomic magnetometers. To achieve high-sensitivity magnetic field measurements, the cells require heating and stabilization at high temperatures. Here, we propose an in-situ temperature measurement method for a vapor cell of an atomic magnetometer based on spin-relaxation analysis. This technique establishes a direct functional correlation between the cell temperature and the spin-relaxation rate under low pumping power conditions. Experimental validation within the temperature range of 90 °C–130 °C confirms the accuracy of this approach. We further investigate the effects of magnetic fields on measurement precision and demonstrate the long-term, high-precision capabilities of temperature detection. This non-invasive technique presents a critical advantage for precise thermal optimization of atomic magnetometers.
Abstract The alkali number density inside the sealed vapor cell restricts the fundamental sensitivity of the atomic magnetometer and may decrease in the long term, thus motivating the investigation of an in situ density determination method on atomic magnetometers. This paper presents a method to measure the alkali number density, which is proportional to the spin-exchange relaxation rate, through phase-frequency analysis. The magnetic resonance response of the atomic magnetometer was actively strengthened at low polarization by increasing the oscillating field amplitude. To downplay the side effect of the transverse field broadening, phase-frequency analysis was applied to extract the transverse relaxation time limited by spin-exchange collisions. The experimental results coincided well with the saturated vapor pressure curve ranging from 413 K to 463 K. Calculated densities were approximately 0.779–0.992 times those of predictions. The density measurement accuracy was improved compared to traditional methods.
This study presents a novel method for measuring the number density of K in K-Rb hybrid vapor cells using circularly polarized pump light on polarized alkali metal atoms. This proposed method eliminates the need for additional devices such as absorption spectroscopy, Faraday rotation, or resistance temperature detector technology. The modeling process involved considering wall loss, scattering loss, atomic absorption loss, and atomic saturation absorption, with experiments designed to identify the relevant parameters. The proposed method is real-time, highly stable, and a quantum nondemolition measurement that does not disrupt the spin-exchange relaxation-free (SERF) regime. Experimental results demonstrate the effectiveness of the proposed method, as the longitudinal electron spin polarization long-term stability increased by 204% and the transversal electron spin polarization long-term stability increased by 44.8%, as evaluated by the Allan variance.