Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Ultra-Low Noise Balanced Receiver with >20 dB Quantum-to-Classical Noise Clearance at 1 GHz

Dinka Milovančev, Florian Honz, Nemanja Vokić, Fabian Laudenbach, Hannes Hübel, Bernhard Schrenk

Published Oct 28, 2021• 1 citation
OpenAlex

Abstract

We demonstrate a die-level balanced homodyne receiver for coherent optical access and continuous-variable quantum applications, featuring a 40dB CMRR up to 1GHz and a high quantum-to-classical noise ratio of 26.8dB at 12.3mW of LO power. 500Mb/s QPSK transmission was accomplished with a sensitivity of -55.8dBm.

Related papers

Ultra-Low Noise Balanced Receiver with >20 dB Quantum-to-Classical Noise Clearance at 1 GHz

Dinka Milovančev, Florian Honz, Nemanja Vokić +3 more

We demonstrate a die-level balanced homodyne receiver for coherent optical access and continuous-variable quantum applications, featuring a 40dB CMRR up to 1GHz and a high quantum to-classical noise ratio of 26.8dB at 12.3mW of LO power. 500Mb/s QPSK transmission was accomplished with a sensitivity of -55.8dBm.

arXiv:2110.15228•European Conference on Optical Communication•Sep 13, 2021•4 citations

Chip-Level GHz Capable Balanced Quantum Homodyne Receivers

Dinka Milovančev, Florian Honz, Nemanja Vokić +5 more

We present a design of balanced homodyne receivers suitable for ultra-low noise quantum applications such as continuous-variable quantum key distribution and quantum random number generation. For best noise and bandwidth performance a die-level low-parasitic photodiode together with a low-noise high-speed transimpedance amplifier are explored together with a planar lightwave circuit splitter chip serving as a photomixer. Bandwidths of 750 MHz and 2.6 GHz were accomplished while maintaining optimum noise performance, as evidenced by very high quantum-to-classical noise ratios of 26.8 and 18.6 dB, respectively. A common-mode rejection ratio of at least 40 dB was achieved for a frequency range of up to 1 GHz. Its application for continuous-variable quantum key distribution was evaluated by means of estimations under a strict untrusted receiver assumption, showing its potential for generating up to 43 Mbit/s secure-key rate over a reach of 10 km, whereas up to 100 Mbit/s could be supported at shorter reaches. Moreover, the high quantum-to-classical clearance values can enable high quality quantum random number generation at Gb/s rates. The multi-purpose operation of the designed balanced receivers for classical communications was examined showing reception sensitivities of −55.8 and −52.6 dBm at 500 Mbit/s and 1 Gbit/s quadrature phase shift keying transmission, respectively, using the 750 MHz receiver. The faster 2.6 GHz receiver enabled 10 Gbit/s duobinary transmission at −14.8 dBm sensitivity.

Journal of Lightwave Technology•Sep 30, 2022•9 citations

Balanced APD homodyne receiver for quantum applications

Dinka Milovančev, Nemanja Vokić, Florian Honz +3 more

Performance of linear avalanche photodiode-based balanced homodyne receiver (APD BHD) is examined and compared to reference BHD based on PIN photodiodes, in terms of common mode rejection ratio (CMRR), quantum-to-classical noise clearance (QCNR) and sensitivity in coherent reception of quadrature phase shift keying (QPSK) modulation format. NIST randomness validation was performed on sampled data for quantum random number generator (QRNG). Achieved CMRR values were 50 dB and 30 dB at 100 MHz and 1 GHz, respectively. QCNR of 20 dB at low input power of −20 dBm was demonstrated. Optical sensitivity of APD BHD coherent receiver compared to its PIN BHD counterpart can be improved by 3 dB at low local oscillator (LO) powers, whereas for high LO powers the sensitivity of APD BHD approaches the values for PIN BHD.

International Conference on Broadband Communications for Next Generation Networks and Multimedia Applications (CoBCom)•Jul 12, 2022•1 citation

A Low-Noise Hybrid-Integrated Balanced Homodyne Receiver with 2.5 GHz Bandwidth and 15 dB Quantum Shot Noise Clearance

Yihao Yang, Chao Zeng Cheng, Ruixuan Yang +5 more

The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.

Micromachines•Dec 17, 2025•0 citations

Die-Level Balanced Homodyne Receiver for Squeezed Light Detection in the GHz Regime

Emmily Zaiser, Alessandro Trenti, Dinka Milovančev +3 more

Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

Low Noise Balanced Homodyne Detector for Quantum Noise Measurement

Shubo Lang, Shicheng Zhang, Xiaolin Li +2 more

The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of$100~\mu \text{w}$. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.

IEEE Access•Jan 1, 2022•4 citations
We present a design of balanced homodyne receivers suitable for ultra-low noise quantum applications such as continuous-variable quantum key distribution and quantum random number generation. For best noise and bandwidth performance a die-level low-parasitic photodiode together with a low-noise high-speed transimpedance amplifier are explored together with a planar lightwave circuit splitter chip serving as a photomixer. Bandwidths of 750 MHz and 2.6 GHz were accomplished while maintaining optimum noise performance, as evidenced by very high quantum-to-classical noise ratios of 26.8 and 18.6 dB, respectively. A common-mode rejection ratio of at least 40 dB was achieved for a frequency range of up to 1 GHz. Its application for continuous-variable quantum key distribution was evaluated by means of estimations under a strict untrusted receiver assumption, showing its potential for generating up to 43 Mbit/s secure-key rate over a reach of 10 km, whereas up to 100 Mbit/s could be supported at shorter reaches. Moreover, the high quantum-to-classical clearance values can enable high quality quantum random number generation at Gb/s rates. The multi-purpose operation of the designed balanced receivers for classical communications was examined showing reception sensitivities of −55.8 and −52.6 dBm at 500 Mbit/s and 1 Gbit/s quadrature phase shift keying transmission, respectively, using the 750 MHz receiver. The faster 2.6 GHz receiver enabled 10 Gbit/s duobinary transmission at −14.8 dBm sensitivity.
Performance of linear avalanche photodiode-based balanced homodyne receiver (APD BHD) is examined and compared to reference BHD based on PIN photodiodes, in terms of common mode rejection ratio (CMRR), quantum-to-classical noise clearance (QCNR) and sensitivity in coherent reception of quadrature phase shift keying (QPSK) modulation format. NIST randomness validation was performed on sampled data for quantum random number generator (QRNG). Achieved CMRR values were 50 dB and 30 dB at 100 MHz and 1 GHz, respectively. QCNR of 20 dB at low input power of −20 dBm was demonstrated. Optical sensitivity of APD BHD coherent receiver compared to its PIN BHD counterpart can be improved by 3 dB at low local oscillator (LO) powers, whereas for high LO powers the sensitivity of APD BHD approaches the values for PIN BHD.
The rapid development of continuous-variable quantum communication has driven an increasing demand for high-performance quantum signal processing modules. Among these, the balanced homodyne detector (BHD) has emerged as a leading solution for practical quantum state measurement due to its capability to provide complete quantum mechanical characterization. However, its performance is often constrained by limited bandwidth and high noise levels, primarily due to the reliance on bulk optical components and discrete receiver electronics. The dominant noise source in these systems typically stems from electronic noise, while imbalances in the optical path further degrade the signal-to-noise ratio (SNR) of the BHD. In this work, we present an adjustable integrated optical path to enhance the balance within the BHD system, along with a low-noise transimpedance amplifier (TIA) by employing optoelectronic co-design. Our design achieves a bandwidth of 2.5 GHz, an input-referred noise current of only 2 pA/√Hz in 180 nm CMOS technology, and a measured quantum shot noise clearance of 15 dB generated from a 700 μA photocurrent. This is the maximum quantum shot noise clearance at the same BHD photocurrent reported to date above the GHz bandwidth.
Quantum receiver scalability and cost-effectiveness are crucial in the evolving quantum landscape. Application based on squeezed light (e.g. high-precision measurements and quantum communication), can profit especially from integrated and low-noise detectors. The presented die-level receiver is shown in figure 1 a) and combines a novel custom transimpedance amplifier (TIA) with commercial photodiodes (PDs) [1]. This offers a more scalable solution than bulk balanced homodyne detectors (BHDs) while being low-cost compared to fully customized receivers. This design targets a high bandwidth operation while maintaining low-noise properties for the detection of weak quantum signals. To characterize this receiver, we evaluate its performance through measurements of clearance, and common-mode rejection ratio (CMRR). Based on these parameters, a simulation for its performance in the squeezed light detection measurement is presented.
The research of quantum noise in the interaction of laser and atoms plays a critical role in quantum optical experiments. The measurement of quantum noise is mainly based on the balanced homodyne detection method. Here, we reported a balanced homodyne detector with low noise, high gain, and high common-mode rejection ratio (CMRR) at the wavelength of 795 nm. By optimizing the selection of components and printed circuit board (PCB) layout, a minimum electronic noise of −96.7 dBm is obtained. Over the range of 1 MHz to 5 MHz, we get a flat CMRR above 59 dB and a linear gain regime, which can enable a shot noise measurement with the laser power of100 μw100~\mu \text{w}100 μw. The developed detector can be used in quantum coherent experiments with a weak probe laser of power down to tens of microwatts.