Measurement Sensors

Progress towards comparison of quantum and classical vacuum standards

Daniel S. Barker, Nikolai N. Klimov, Eite Tiesinga, James A. Fedchak, Julia K. Scherschligt, Stephen Eckel

Published Sep 22, 2021• 8 citations
Publisher

Abstract

We present our progress towards a comparison of NIST's cold atom primary vacuum standard and a dynamic expansion vacuum standard. The cold atom vacuum standard (CAVS) converts the loss rate of atoms from a magnetic trap to a vacuum pressure using ab initio calculations of the quantum atom-molecule collision cross-section. To validate the CAVS, we have constructed a new flowmeter and dynamic expansion system that can produce low-uncertainty pressures in the ultra-high-vacuum range that is required for atom trapping. We discuss the operation and systematics of both the CAVS and flowmeter.

DOI
10.1016/j.measen.2021.100229

Related papers

Precise quantum measurement of vacuum with cold atoms

Daniel S. Barker, B. P. Acharya, James A. Fedchak +5 more

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

Review of Scientific Instruments•Dec 1, 2022•15 citations

Progress towards a primary pressure standard with cold atoms

Kais Jooya

This thesis describes a method of using an ultra-cold ensemble of atoms confined in a trap as an atomic primary pressure standard. The development of the standard and its current status are described in detail. This standard uses a 3D MOT to trap ⁸⁷Rb and then transfer them to a quadrupole magnetic trap where the atoms undergoes collisions with a background gas. By measuring the number of atoms left in the magnetic trap as a function of time one extract a loss rate and from this rate determine the background gas density. This loss rate is a product of the density of the background, multiplied by the loss cross section averaged over the velocity distribution of the background gas. By computing the average loss cross section in the magnetic trap and measuring the loss rate, the density of the background gas can be determined. This gives a calibration free measurement of density of a background gas in the UHV range (10-⁶ ‑ 10-⁹) Torr or (10-⁴ - 10-⁷) Pa which allows for it to be used as a standard. In conjunction with this, preparation of the atoms prior to the loss rate measurement is investigated to ensure accuracy and reproducibility of the standard. Finally a comparison between UBC's atomic standard and NIST's (National Institute for Standards and Technology) orifice flow standard is conducted via an ionization gauge which employed as a transfer standard.All measurement are carried out using Argon gas as the background gas of study.

•Jan 1, 2017•0 citations

Roadmap on Quantum Sensors for Vacuum Metrology

D. S. Barker, J. L. Booth, S. P. Eckel +7 more

We describe how laser-cooled and trapped alkali-metal atoms have been used as pressure sensors in the high- and ultra-high-vacuum regimes operating with relative uncertainties of just over a percent at pressures from a few nPa and up to a few tens of $μ$Pa. These sensors can serve as primary standards of pressure as the determination of pressure requires only knowledge of collision cross sections between atoms and molecules, eliminating the need for calibration with other devices. The collision cross sections can be measured independently or computed with rigorous quantum methods at percent relative accuracies. We argue that this technology has advanced sufficiently to provide an alternative to the existing, expensive pressure standard in the ultra-high vacuum regime, the orifice flow standard. Experiments with trapped atoms can be used to calibrate cheaper pressure sensors (such as devices based on ionization gauges). However, the technology has not yet matured enough to be of use in other research fields because of the complexity and cost of the experiments. We propose a roadmap for this new pressure standard for vacuum metrology.

physics.atom-phCross-listedarXiv:2609.06626•Sep 8, 2026•0 citations

Accurate measurement of the loss rate of cold atoms due to background gas collisions for the quantum-based cold atom vacuum standard

Daniel S. Barker, James A. Fedchak, Jacek A. Kłos +4 more

We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.

arXiv:2302.12143•AVS Quantum Science•Aug 1, 2023•22 citations

Effect of glancing collisions in the cold-atom vacuum standard

Stephen Eckel, Daniel S. Barker, James A. Fedchak +3 more

We theoretically investigate the effect of ``glancing'' collisions on the ultra-high-vacuum pressure readings of the cold-atom vacuum standard (CAVS), based on either ultracold $^{7}\mathrm{Li}$ or $^{87}\mathrm{Rb}$ atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is nonexponential. We update the recent results of a comparison between a traditional pressure standard---a combined flow meter and dynamic expansion system---and the CAVS [D. S. Barker et al., AVS Quantum Sci. 5, 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for $^{7}\mathrm{Li}$ colliding with noble gases or ${\mathrm{N}}_{2}$ by up to 0.6%. Likewise, we find that in the limit of zero trap depth, the experimentally extracted loss rate coefficients for $^{87}\mathrm{Rb}$ colliding with noble gases or ${\mathrm{N}}_{2}$ shift by as much as 2.2%.

arXiv:2409.11226•Physical Review A•Feb 12, 2025•2 citations

Comparison of two multiplexed portable cold-atom vacuum standards

L. Ehinger, B. P. Acharya, Daniel S. Barker +4 more

We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.

arXiv:2204.03705•AVS Quantum Science•Jul 15, 2022•24 citations
We present our progress towards a comparison of NIST's cold atom primary vacuum standard and a dynamic expansion vacuum standard. The cold atom vacuum standard (CAVS) converts the loss rate of atoms from a magnetic trap to a vacuum pressure using ab initio calculations of the quantum atom-molecule collision cross-section. To validate the CAVS, we have constructed a new flowmeter and dynamic expansion system that can produce low-uncertainty pressures in the ultra-high-vacuum range that is required for atom trapping. We discuss the operation and systematics of both the CAVS and flowmeter.
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
This thesis describes a method of using an ultra-cold ensemble of atoms confined in a trap as an atomic primary pressure standard. The development of the standard and its current status are described in detail. This standard uses a 3D MOT to trap ⁸⁷Rb and then transfer them to a quadrupole magnetic trap where the atoms undergoes collisions with a background gas. By measuring the number of atoms left in the magnetic trap as a function of time one extract a loss rate and from this rate determine the background gas density. This loss rate is a product of the density of the background, multiplied by the loss cross section averaged over the velocity distribution of the background gas. By computing the average loss cross section in the magnetic trap and measuring the loss rate, the density of the background gas can be determined. This gives a calibration free measurement of density of a background gas in the UHV range (10-⁶ ‑ 10-⁹) Torr or (10-⁴ - 10-⁷) Pa which allows for it to be used as a standard. In conjunction with this, preparation of the atoms prior to the loss rate measurement is investigated to ensure accuracy and reproducibility of the standard. Finally a comparison between UBC's atomic standard and NIST's (National Institute for Standards and Technology) orifice flow standard is conducted via an ionization gauge which employed as a transfer standard.All measurement are carried out using Argon gas as the background gas of study.
We describe how laser-cooled and trapped alkali-metal atoms have been used as pressure sensors in the high- and ultra-high-vacuum regimes operating with relative uncertainties of just over a percent at pressures from a few nPa and up to a few tens of μμμPa. These sensors can serve as primary standards of pressure as the determination of pressure requires only knowledge of collision cross sections between atoms and molecules, eliminating the need for calibration with other devices. The collision cross sections can be measured independently or computed with rigorous quantum methods at percent relative accuracies. We argue that this technology has advanced sufficiently to provide an alternative to the existing, expensive pressure standard in the ultra-high vacuum regime, the orifice flow standard. Experiments with trapped atoms can be used to calibrate cheaper pressure sensors (such as devices based on ionization gauges). However, the technology has not yet matured enough to be of use in other research fields because of the complexity and cost of the experiments. We propose a roadmap for this new pressure standard for vacuum metrology.
We present the measurements of thermalized collisional rate coefficients for ultra-cold 7Li and 87Rb colliding with room-temperature He, Ne, N2, Ar, Kr, and Xe. In our experiments, a combined flowmeter and dynamic expansion system, a vacuum metrology standard, is used to set a known number density for the room-temperature background gas in the vicinity of the magnetically trapped 7Li or 87Rb clouds. Each collision with a background atom or molecule removes a 7Li or 87Rb atom from its trap, and the change in the atom loss rate with background gas density is used to determine the thermalized loss rate coefficients with fractional standard uncertainties better than 1.6% for 7Li and 2.7% for 87Rb. We find consistency—a degree of equivalence of less than one—between the measurements and recent quantum-scattering calculations of the loss rate coefficients [Kłos and Tiesinga, J. Chem. Phys. 158, 014308 (2023)], with the exception of the loss rate coefficient for both 7Li and 87Rb colliding with Ar. Nevertheless, the agreement between theory and experiment for all other studied systems provides validation that a quantum-based measurement of vacuum pressure using cold atoms also serves as a primary standard for vacuum pressure, which we refer to as the cold-atom vacuum standard.
We theoretically investigate the effect of ``glancing'' collisions on the ultra-high-vacuum pressure readings of the cold-atom vacuum standard (CAVS), based on either ultracold 7Li^{7}\mathrm{Li}7Li or 87Rb^{87}\mathrm{Rb}87Rb atoms. Here, glancing collisions are those collisions between ultracold atoms and room-temperature background atoms or molecules in the vacuum that do not impart enough kinetic energy to eject an ultracold atom from its trap. Our model is wholly probabilistic and shows that the number of the ultracold atoms remaining in the trap as a function of time is nonexponential. We update the recent results of a comparison between a traditional pressure standard---a combined flow meter and dynamic expansion system---and the CAVS [D. S. Barker et al., AVS Quantum Sci. 5, 035001 (2023)] to reflect the results of our model. We find that the effect of glancing collisions shifts the theoretical predictions of the total loss rate coefficients for 7Li^{7}\mathrm{Li}7Li colliding with noble gases or N2{\mathrm{N}}_{2}N2​ by up to 0.6%. Likewise, we find that in the limit of zero trap depth, the experimentally extracted loss rate coefficients for 87Rb^{87}\mathrm{Rb}87Rb colliding with noble gases or N2{\mathrm{N}}_{2}N2​ shift by as much as 2.2%.
We compare the vacuum measured by two portable cold-atom vacuum standards (pCAVSs) based on ultracold 7Li atoms. pCAVSs are quantum-based standards that use a priori scattering calculations to convert a measured loss rate of cold atoms from a conservative trap into a background gas pressure. Our pCAVS devices share the same laser system and measure the vacuum concurrently. The two pCAVSs together detected a leak with a rate on the order of 10−6 Pa l/s. After fixing the leak, the pCAVS measured pressure of about 40 nPa with 2.6% uncertainty. The two pCAVSs agree within their uncertainties, even when swapping some of their component parts. Operation of the pCAVS was found to cause some additional outgassing, on the order of 10−8 Pa l/s, which can be mitigated in the future by better thermal management.