Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2609.06626

Roadmap on Quantum Sensors for Vacuum Metrology

D. S. Barker, J. L. Booth, S. P. Eckel, J. Grosse, K. Jousten, J. Kłos, R. V. Krems, K. W. Madison, T. Rubin, E. Tiesinga

physics.atom-phquant-phSubmitted Sep 6, 2026• Announced Sep 8, 2026• 0 citations
arXivHTMLPDF

Abstract

We describe how laser-cooled and trapped alkali-metal atoms have been used as pressure sensors in the high- and ultra-high-vacuum regimes operating with relative uncertainties of just over a percent at pressures from a few nPa and up to a few tens of $μ$Pa. These sensors can serve as primary standards of pressure as the determination of pressure requires only knowledge of collision cross sections between atoms and molecules, eliminating the need for calibration with other devices. The collision cross sections can be measured independently or computed with rigorous quantum methods at percent relative accuracies. We argue that this technology has advanced sufficiently to provide an alternative to the existing, expensive pressure standard in the ultra-high vacuum regime, the orifice flow standard. Experiments with trapped atoms can be used to calibrate cheaper pressure sensors (such as devices based on ionization gauges). However, the technology has not yet matured enough to be of use in other research fields because of the complexity and cost of the experiments. We propose a roadmap for this new pressure standard for vacuum metrology.

Related papers

Realization of a universal quantum pressure standard

Pinrui Shen, Kirk W. Madison, James L. Booth

We report the realization of the first cold-atom primary standard. This standard is based on a universal law governing quantum diffractive collisions between particles that allows an experimental determination of the velocity averaged total collision cross section, the only parameter required to quantify the pressure or flux of particles given a sensor particle collision rate measurement. Using an ensemble of 87Rb sensor atoms, we show that this new quantum pressure standard can be applied to gases of both atomic (He, Ar, and Xe) and molecular species (, , and ), surpassing the scope of existing orifice flow pressure standards. We verify the accuracy of this new standard using an ionization gauge (IG) calibrated for N2 by an orifice flow standard. The gauge calibration factors determined by the cold atom and orifice flow standards differ by less than 0.5% and, thus, agree within their uncertainties of 2% and 2.8% respectively. Using this standard, we evaluate the response of two different IGs to a variety of different gas species and report variations of up to 20% for their measured calibration factors. We also observe a non-linear response of the IG readings for CO2 gas. Finally, we demonstrate the use of a magneto-optical trap (MOT) as a transfer standard to extend the measurement range by a factor of 100 to include pressures up to P ~ 10−5 Pa.

Bulletin of the American Physical Society•Jun 2, 2020•0 citations

Cross-calibration of atomic sensors for pressure metrology

Erik Frieling, Riley A. Stewart, James L. Booth +1 more

Atomic sensors have shown great promise for density and pressure metrology in the high, ultra-high, and extremely-high vacuum regimes. Specifically, the density of background gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of changes of that state, and using the cross section coefficient for state-changing collisions to convert the rate into a corresponding density. The cross section can be known by various methods including by quantum scattering calculations using an ansatz for the interaction potential between the collision pair, by measurements of the post-collision sensor-atom momentum recoil distribution, or by empirical calibration of the sensor atom at a known density. Identifying systematic errors in the results of these methods can be aided by direct comparisons between them. Alternatively, measurements of different sensor atoms exposed to the same background gas offers another point of comparison free of the systematic errors inherent in creating a background gas at a known density. Here, we present such measurements for two sensor atoms, $^{87}$Rb and $^6$Li, and a variety of atomic and molecular background gases including H$_2$, N$_2$, Ar, Ne, Kr, and Xe. We find results consistent with, yet statistically different at the level of 3.5(5)%, from recent theoretical and experiment measurements. This work demonstrates a model-free method for transferring the primacy of one atomic standard to another sensor atom and highlights the utility of sensor-atom cross-calibration experiments to check the validity of direct measurements and theoretical predictions.

arXiv:2312.15446•Dec 24, 2023•1 citation

Realization of a universal quantum pressure standard

Pinrui Shen, Kirk W. Madison, James L. Booth

Abstract We report the realization of the first cold-atom primary standard. This standard is based on a universal law governing quantum diffractive collisions between particles that allows an experimental determination of the velocity averaged total collision cross section, the only parameter required to quantify the pressure or flux of particles given a sensor particle collision rate measurement. Using an ensemble of 87Rb sensor atoms, we show that this new quantum pressure standard can be applied to gases of both atomic (He, Ar, and Xe) and molecular species ( N 2 , C O 2 , and H 2 ), surpassing the scope of existing orifice flow pressure standards. We verify the accuracy of this new standard using an ionization gauge (IG) calibrated for N2 by an orifice flow standard. The gauge calibration factors determined by the cold atom and orifice flow standards differ by less than 0.5% and, thus, agree within their uncertainties of 2% and 2.8% respectively. Using this standard, we evaluate the response of two different IGs to a variety of different gas species and report variations of up to 20% for their measured calibration factors. We also observe a non-linear response of the IG readings for CO2 gas. Finally, we demonstrate the use of a magneto-optical trap (MOT) as a transfer standard to extend the measurement range by a factor of 100 to include pressures up to P ~ 10−5 Pa.

Metrologia•Jan 29, 2020•30 citations

Precise quantum measurement of vacuum with cold atoms

Daniel S. Barker, B. P. Acharya, James A. Fedchak +5 more

We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.

Review of Scientific Instruments•Dec 1, 2022•15 citations

Vacuum pressure measurement of cold 7Li atoms in the magneto-optical and magnetic trap

Xuejiao Zhang, R. X. Li, Jingyi Zhang +2 more

Cold atoms play a very important role in metrology. The ultra-high or extreme-high vacuum pressure can be accurately measured by investigating the collision of cold atoms and residual atoms in the environment. We report a vacuum pressure metrometer using cold 7Li atoms as sensor atoms in a magneto-optical trap and a magnetic trap. The accuracy, uncertainty, and feasibility of the measurements in such two different traps are studied and compared in the pressure range from 10−5 to 10−8 Pa. It is found that the vacuum pressure measurement in a magneto-optical trap is more advantageous with a higher accuracy, higher signal-to-noise ratio, and shorter measurement time under current conditions. The results may be used to realize an applicable cold atom quantum vacuum standard.

AIP Advances•May 1, 2023•1 citation

Cross-calibration of quantum atomic sensors for pressure metrology

Erik Frieling, Riley A. Stewart, James L. Booth +1 more

Quantum atomic sensors have shown great promise for vacuum metrology. Specifically, the density of gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of changes of that state, and using the total collision rate coefficient for state-changing collisions to convert the rate into a corresponding density. The total collision rate coefficient can be known by various methods, including quantum scattering calculations using a computed interaction potential for the collision pair, measurements of the post-collision sensor-atom momentum recoil distribution, or empirical measurements of the collision rate at a known density. Observed discrepancies between the results of these methods call into question their accuracy. To investigate this, we study the ratio of collision rate measurements of co-located sensor atoms, 87Rb and 6Li, exposed to natural abundance versions of H2, He, N2, Ne, Ar, Kr, and Xe gases. This method does not require knowledge of the test gas density and is, therefore, free of the systematic errors inherent in efforts to introduce the test gas at a known density. Our results are systematically different at the level of 3% to 4% from recent theoretical and experiment measurements. This work demonstrates a model-free method for transferring the primacy of one atomic standard to another sensor atom and highlights the utility of sensor-atom cross-calibration experiments to check the validity of direct measurements and theoretical predictions.

AVS Quantum Science•May 10, 2024•5 citations
We describe how laser-cooled and trapped alkali-metal atoms have been used as pressure sensors in the high- and ultra-high-vacuum regimes operating with relative uncertainties of just over a percent at pressures from a few nPa and up to a few tens of μμμPa. These sensors can serve as primary standards of pressure as the determination of pressure requires only knowledge of collision cross sections between atoms and molecules, eliminating the need for calibration with other devices. The collision cross sections can be measured independently or computed with rigorous quantum methods at percent relative accuracies. We argue that this technology has advanced sufficiently to provide an alternative to the existing, expensive pressure standard in the ultra-high vacuum regime, the orifice flow standard. Experiments with trapped atoms can be used to calibrate cheaper pressure sensors (such as devices based on ionization gauges). However, the technology has not yet matured enough to be of use in other research fields because of the complexity and cost of the experiments. We propose a roadmap for this new pressure standard for vacuum metrology.
We report the realization of the first cold-atom primary standard. This standard is based on a universal law governing quantum diffractive collisions between particles that allows an experimental determination of the velocity averaged total collision cross section, the only parameter required to quantify the pressure or flux of particles given a sensor particle collision rate measurement. Using an ensemble of 87Rb sensor atoms, we show that this new quantum pressure standard can be applied to gases of both atomic (He, Ar, and Xe) and molecular species (, , and ), surpassing the scope of existing orifice flow pressure standards. We verify the accuracy of this new standard using an ionization gauge (IG) calibrated for N2 by an orifice flow standard. The gauge calibration factors determined by the cold atom and orifice flow standards differ by less than 0.5% and, thus, agree within their uncertainties of 2% and 2.8% respectively. Using this standard, we evaluate the response of two different IGs to a variety of different gas species and report variations of up to 20% for their measured calibration factors. We also observe a non-linear response of the IG readings for CO2 gas. Finally, we demonstrate the use of a magneto-optical trap (MOT) as a transfer standard to extend the measurement range by a factor of 100 to include pressures up to P ~ 10−5 Pa.
Atomic sensors have shown great promise for density and pressure metrology in the high, ultra-high, and extremely-high vacuum regimes. Specifically, the density of background gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of changes of that state, and using the cross section coefficient for state-changing collisions to convert the rate into a corresponding density. The cross section can be known by various methods including by quantum scattering calculations using an ansatz for the interaction potential between the collision pair, by measurements of the post-collision sensor-atom momentum recoil distribution, or by empirical calibration of the sensor atom at a known density. Identifying systematic errors in the results of these methods can be aided by direct comparisons between them. Alternatively, measurements of different sensor atoms exposed to the same background gas offers another point of comparison free of the systematic errors inherent in creating a background gas at a known density. Here, we present such measurements for two sensor atoms, 87^{87}87Rb and 6^66Li, and a variety of atomic and molecular background gases including H2_22​, N2_22​, Ar, Ne, Kr, and Xe. We find results consistent with, yet statistically different at the level of 3.5(5)%, from recent theoretical and experiment measurements. This work demonstrates a model-free method for transferring the primacy of one atomic standard to another sensor atom and highlights the utility of sensor-atom cross-calibration experiments to check the validity of direct measurements and theoretical predictions.
Abstract We report the realization of the first cold-atom primary standard. This standard is based on a universal law governing quantum diffractive collisions between particles that allows an experimental determination of the velocity averaged total collision cross section, the only parameter required to quantify the pressure or flux of particles given a sensor particle collision rate measurement. Using an ensemble of 87Rb sensor atoms, we show that this new quantum pressure standard can be applied to gases of both atomic (He, Ar, and Xe) and molecular species ( N 2 , C O 2 , and H 2 ), surpassing the scope of existing orifice flow pressure standards. We verify the accuracy of this new standard using an ionization gauge (IG) calibrated for N2 by an orifice flow standard. The gauge calibration factors determined by the cold atom and orifice flow standards differ by less than 0.5% and, thus, agree within their uncertainties of 2% and 2.8% respectively. Using this standard, we evaluate the response of two different IGs to a variety of different gas species and report variations of up to 20% for their measured calibration factors. We also observe a non-linear response of the IG readings for CO2 gas. Finally, we demonstrate the use of a magneto-optical trap (MOT) as a transfer standard to extend the measurement range by a factor of 100 to include pressures up to P ~ 10−5 Pa.
We describe the cold-atom vacuum standards (CAVS) under development at the National Institute of Standards and Technology (NIST). The CAVS measures pressure in the ultra-high and extreme-high vacuum regimes by measuring the loss rate of sub-millikelvin sensor atoms from a magnetic trap. Ab initio quantum scattering calculations of cross sections and rate coefficients relate the density of background gas molecules or atoms to the loss rate of ultra-cold sensor atoms. The resulting measurement of pressure through the ideal gas law is traceable to the second and the kelvin, making it a primary realization of the pascal. At NIST, two versions of the CAVS have been constructed: a laboratory standard used to achieve the lowest possible uncertainties and pressures, and a portable version that is a potential replacement for the Bayard-Alpert ionization gauge. Both types of CAVSs are connected to a combined extreme-high vacuum flowmeter and dynamic expansion system to enable sensing of a known pressure of gas. In the near future, we anticipate being able to compare the laboratory scale CAVS, the portable CAVS, and the flowmeter/dynamic expansion system to validate the operation of the CAVS as both a standard and vacuum gauge.
Cold atoms play a very important role in metrology. The ultra-high or extreme-high vacuum pressure can be accurately measured by investigating the collision of cold atoms and residual atoms in the environment. We report a vacuum pressure metrometer using cold 7Li atoms as sensor atoms in a magneto-optical trap and a magnetic trap. The accuracy, uncertainty, and feasibility of the measurements in such two different traps are studied and compared in the pressure range from 10−5 to 10−8 Pa. It is found that the vacuum pressure measurement in a magneto-optical trap is more advantageous with a higher accuracy, higher signal-to-noise ratio, and shorter measurement time under current conditions. The results may be used to realize an applicable cold atom quantum vacuum standard.
Quantum atomic sensors have shown great promise for vacuum metrology. Specifically, the density of gas particles in vacuum can be determined by measuring the collision rate between the particles and an ensemble of sensor atoms. This requires preparing the sensor atoms in a particular quantum state, observing the rate of changes of that state, and using the total collision rate coefficient for state-changing collisions to convert the rate into a corresponding density. The total collision rate coefficient can be known by various methods, including quantum scattering calculations using a computed interaction potential for the collision pair, measurements of the post-collision sensor-atom momentum recoil distribution, or empirical measurements of the collision rate at a known density. Observed discrepancies between the results of these methods call into question their accuracy. To investigate this, we study the ratio of collision rate measurements of co-located sensor atoms, 87Rb and 6Li, exposed to natural abundance versions of H2, He, N2, Ne, Ar, Kr, and Xe gases. This method does not require knowledge of the test gas density and is, therefore, free of the systematic errors inherent in efforts to introduce the test gas at a known density. Our results are systematically different at the level of 3% to 4% from recent theoretical and experiment measurements. This work demonstrates a model-free method for transferring the primacy of one atomic standard to another sensor atom and highlights the utility of sensor-atom cross-calibration experiments to check the validity of direct measurements and theoretical predictions.