Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum-enhanced sensing of displacements and electric fields with large trapped-ion crystals

Diego Barberena, Kevin Gilmore, M. Affolter, Robert J. Lewis-Swan, J. E. Jordan, Ana María Rey, John Bollinger

Published Jun 1, 2021• 0 citations
OpenAlex

Related papers

Quantum sensing electric fields with trapped ions

Jordi Mur-Petit

•Mar 26, 2015•0 citations

Quantum-enhanced sensing of displacements and electric fields with two-dimensional trapped-ion crystals

Kevin Gilmore, M. Affolter, Robert J. Lewis-Swan +4 more

mechanical oscillator, and the collective electronic spin serves as the measurement device. By entangling the oscillator and collective spin and controlling the coherent dynamics via a many-body echo, a displacement is mapped into a spin rotation while avoiding quantum back-action and thermal noise. We achieve a sensitivity to displacements of 8.8 ± 0.4 decibels below the standard quantum limit and a sensitivity for measuring electric fields of 240 ± 10 nanovolts per meter in 1 second. Feasible improvements should enable the use of trapped ions in searches for dark matter.

arXiv:2103.08690•Science•Aug 5, 2021•201 citations

Quantum sensing with 2D arrays of trapped ions

Kevin Gilmore, M. Affolter, J. E. Jordan +4 more

Bulletin of the American Physical Society•May 29, 2019•0 citations

Phase-coherent sensing of the center-of-mass motion of trapped-ion crystals

M. Affolter, Kevin Gilmore, J. E. Jordan +1 more

Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A $49\phantom{\rule{4pt}{0ex}}\mathrm{pm}$ displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an $8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}$ displacement sensitivity is achieved, which implies $12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}$ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and $1\phantom{\rule{4pt}{0ex}}\mathrm{nV}$/m, respectively.

arXiv:2008.00035•Physical Review A•Nov 9, 2020•25 citations

Non-classical motional states of a trapped ion for quantum-enhanced sensing

Katherine C. McCormick, Dietrich G. Leibfried, A. C. Wilson +3 more

Bulletin of the American Physical Society•May 30, 2018•0 citations

Electric field distortions in surface ion traps with integrated nanophotonics

Guochun Du, Elena Jordan, T. E. Mehlstäubler

The integration of photonic components into surface ion traps provides a scalable approach for trapped-ion quantum computing, sensing, and metrology, enabling compact systems with enhanced stability and precision. However, the introduction of optical apertures in the trap electrodes can distort the trapping electric field. This can lead to excess micromotion and ion displacement, which degrade the performance of quantum logic operations and optical clocks. In this work, we systematically investigate the electric field distortion in a surface ion trap with integrated waveguides and grating couplers that require apertures in the surface electrode using finite element method simulations. We analyze methods to reduce these distortions by exploiting symmetries and transparent conductive oxide materials.

arXiv:2503.20387•Physical Review Applied•Apr 28, 2026•2 citations
mechanical oscillator, and the collective electronic spin serves as the measurement device. By entangling the oscillator and collective spin and controlling the coherent dynamics via a many-body echo, a displacement is mapped into a spin rotation while avoiding quantum back-action and thermal noise. We achieve a sensitivity to displacements of 8.8 ± 0.4 decibels below the standard quantum limit and a sensitivity for measuring electric fields of 240 ± 10 nanovolts per meter in 1 second. Feasible improvements should enable the use of trapped ions in searches for dark matter.
Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A 49pm49\phantom{\rule{4pt}{0ex}}\mathrm{pm}49pm displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an 8.4pm/Hz8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}8.4pm/Hz​ displacement sensitivity is achieved, which implies 12(yN/ion)/Hz12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}12(yN/ion)/Hz​ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and 1nV1\phantom{\rule{4pt}{0ex}}\mathrm{nV}1nV/m, respectively.
The integration of photonic components into surface ion traps provides a scalable approach for trapped-ion quantum computing, sensing, and metrology, enabling compact systems with enhanced stability and precision. However, the introduction of optical apertures in the trap electrodes can distort the trapping electric field. This can lead to excess micromotion and ion displacement, which degrade the performance of quantum logic operations and optical clocks. In this work, we systematically investigate the electric field distortion in a surface ion trap with integrated waveguides and grating couplers that require apertures in the surface electrode using finite element method simulations. We analyze methods to reduce these distortions by exploiting symmetries and transparent conductive oxide materials.