Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Velocity-selective imaging using cesium-based photon detectors

Nathan C. Pixley

Published Jan 1, 2002• 0 citations
OpenAlex

Related papers

A resonance ionization imaging detector based on cesium atomic vapor

J. P. Temirov, Nikolay Chigarev, Oleg I. Matveev +3 more

Spectrochimica Acta Part B Atomic Spectroscopy•May 1, 2004•13 citations

Resolution enhancement in noise spectrum by using velocity selective optical pumping in cesium vapor

Yuan Li, De-Huan Cai, Rong Ma +3 more

Applied Physics B•Oct 13, 2012•8 citations

Sub-Doppler Spectral Resolution and Improved Sensitivity in a Cesium Resonance Fluorescence Imaging Monochromator

Nathan C. Pixley, Tiffany L. Correll, Dimitri Pappas +2 more

Improvements in spectral resolution and sensitivity of a cesium based resonance fluorescence imaging monochromator (RFIM) are described. Alignment of the two lasers used in the excitation scheme in a co-propagating geometry have resulted in a detector spectral bandpass (270 MHz) that is narrower than the Doppler broadened profile (380 MHz) of cesium vapor at room temperature. Improvements in the experimental design, namely the addition of an image intensifier and cooled charge-coupled device (CCD) camera, have resulted in increased sensitivity; we report a limit of detection of 10 8 photons per pixel limited by image intensifier noise. Images of the cesium D 2 line emission (852.12 nm) from a cesium hollow cathode lamp were compared to an argon emission line (4Sº 1/2 → 4P 3/2 ) at 852.14 nm from a silver/argon hollow cathode lamp as a demonstration of the spectral resolution. The ability of the RFIM to discriminate between photons exciting the F = 4 vs. F = 3 ground state hyperfine level (a frequency difference of 9.2 GHz) of the cesium 6 2 S 1/2 state was also investigated to further demonstrate the spectral selectivity. The potential use of the described RFIM for chemical imaging applications is discussed.

Applied Spectroscopy•Jun 1, 2002•10 citations

A fictitious photons method for tomographic imaging

Giacomo Mauro D’Ariano, Chiara Macchiavello, Matteo G. A. Paris

Optics Communications•Aug 1, 1996•8 citations

Stimulated photon echo study of velocity-changing collisions

Ravinder Kachru, THOMAS W. MOSSBERG, Sven R. Hartmann

Optics Communications•Jul 1, 1979•28 citations

Tunable resonance fluorescence monochromator with sub-Doppler spectral resolution

Nathan C. Pixley, Tiffany L. Correll, Dimitri Pappas +3 more

A cesium-based resonance fluorescence monochromator with a spectral resolution of 200 MHz and a tunable response over the D(2) absorption line of cesium (380 MHz) is described. The narrow spectral response is achieved through excitation of a monokinetic population of the 6(2)P(3/2)( degrees ) state by arrangement of the excitation lasers in either a copropagating or a counterpropagating orientation. The narrow spectral response of the detector allows for excitation of specific hyperfine components involved in the 6(2)P(3/2)( degrees ) (F=3-5) to 6(2)D(5/2) (F=2-6) transition (917.23 nm). The selectivity gained through resolving specific hyperfine transitions allows for a photon detector that is both spectrally tunable and narrow. We report the sub-Doppler linewidths achieved through various laser beam orientations. We also describe how these beam geometries can be applied to spectrally narrow and tunable image detection.

Optics Letters•Dec 15, 2001•15 citations
Improvements in spectral resolution and sensitivity of a cesium based resonance fluorescence imaging monochromator (RFIM) are described. Alignment of the two lasers used in the excitation scheme in a co-propagating geometry have resulted in a detector spectral bandpass (270 MHz) that is narrower than the Doppler broadened profile (380 MHz) of cesium vapor at room temperature. Improvements in the experimental design, namely the addition of an image intensifier and cooled charge-coupled device (CCD) camera, have resulted in increased sensitivity; we report a limit of detection of 10 8 photons per pixel limited by image intensifier noise. Images of the cesium D 2 line emission (852.12 nm) from a cesium hollow cathode lamp were compared to an argon emission line (4Sº 1/2 → 4P 3/2 ) at 852.14 nm from a silver/argon hollow cathode lamp as a demonstration of the spectral resolution. The ability of the RFIM to discriminate between photons exciting the F = 4 vs. F = 3 ground state hyperfine level (a frequency difference of 9.2 GHz) of the cesium 6 2 S 1/2 state was also investigated to further demonstrate the spectral selectivity. The potential use of the described RFIM for chemical imaging applications is discussed.
A cesium-based resonance fluorescence monochromator with a spectral resolution of 200 MHz and a tunable response over the D(2) absorption line of cesium (380 MHz) is described. The narrow spectral response is achieved through excitation of a monokinetic population of the 6(2)P(3/2)( degrees ) state by arrangement of the excitation lasers in either a copropagating or a counterpropagating orientation. The narrow spectral response of the detector allows for excitation of specific hyperfine components involved in the 6(2)P(3/2)( degrees ) (F=3-5) to 6(2)D(5/2) (F=2-6) transition (917.23 nm). The selectivity gained through resolving specific hyperfine transitions allows for a photon detector that is both spectrally tunable and narrow. We report the sub-Doppler linewidths achieved through various laser beam orientations. We also describe how these beam geometries can be applied to spectrally narrow and tunable image detection.