Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

OSA Continuum

Selection of a Raman beam waist in atomic gravimetry

J. M. Cervantes, Mario A. Maldonado, J. A. Franco-Villafañe, Timothy Roach, Victor Manuel Valenzuela, E. Gómez

Published Jun 9, 2021• 9 citations
Publisher

Abstract

The laser beam waist has an impact both in the sensitivity and systematic effects present in gravimetry and atom interferometry in general. In this paper we consider how different effects contribute to both aspects in order to make a better selection of the radius of the Raman beam given a particular laser power available. A large beam waist reduces systematic effects coming from wavefront curvature and Gouy phase contributions and improves the fringe contrast due to reduced intensity gradients. On the other hand, a large waist gives a smaller Rabi frequency, which lowers the sensitivity by reducing the fraction of atoms in the selected velocity range. Considering all contributions, we find that systematic effects usually have a dominant role in selecting a beam waist.

DOI
10.1364/osac.414110

Related papers

Effects of wave-front tilt and air density fluctuations in a sensitive atom interferometry gyroscope

Wenjie Xu, Ling Cheng, Jie Liu +8 more

. The atom interferometry gyroscope is driven by a π/2 - π - π - π/2 Raman pulse sequence based on an atom fountain with a parabolic trajectory. The phase-locked laser beams for Raman transitions partly propagate outside of the vacuum chamber and expose to the air when passing through the two arms of the vacuum chamber. This configuration leads to the tilt of the laser's wave-front and suffers the fluctuation of air density. The impacts on both the fringe contrast and long-term stability are experimentally investigated in detail, and effective schemes are developed to improve the performance of our atom gyroscope. The method presented here could be useful for developing large atom interferometry facilities with separated vacuum chambers.

Optics Express•Apr 1, 2020•22 citations

Wave-front curvature in optical atomic beam clocks

Aidan Strathearn, Rachel F. Offer, Ashby Paul Hilton +5 more

Atomic clocks provide a reproducible basis for our understanding of time and frequency. Recent demonstrations of compact optical clocks, employing thermal atomic beams, have achieved short-term fractional frequency instabilities of order ${10}^{\ensuremath{-}16}$, competitive with the best international frequency standards available. However, a serious challenge inherent in compact clocks is the necessarily smaller optical beams, which results in rapid variation in interrogating wave fronts. This can cause inhomogeneous excitation of the thermal beam leading to long-term drifts in the output frequency. Here we develop a model for Ramsey-Bord\'e interferometry using optical fields with curved wave fronts and simulate the $^{40}\mathrm{Ca}$ beam clock experiment described by Olson et al. [Phys. Rev. Lett. 123, 073202 (2019)]. The results of Olson et al. showed surprising and unexplained behavior in the response of the atoms in the interrogation. Our model predicts signals consistent with experimental data and can account for the significant sensitivity to laser geometry that was reported. We find the signal-to-noise ratio is maximized when the laser is uncollimated at the interrogation zones to minimize inhomogeneity and also identify an optimal waist size determined by both laser inhomogeneity and the velocity distribution of the atomic beam. We investigate the shifts and stability of the clock frequency, showing that the Gouy phase is the primary source of frequency variations arising from laser geometry.

arXiv:2212.00308•Physical Review A•Jul 11, 2023•5 citations

Improving the Accuracy of Atom Gravimeters with Ultracold Sources

Romain Karcher, Almazbek Imanaliev, Sébastien Merlet +1 more

Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•0 citations

Compensation of motion-induced atom-laser misalignment errors in an atom-interferometry gravimeter

Yishu Yang, Yukun Luo, Fufang Xu

Atomic gravimeter based on atom interferometry has become a hotspot of quantum optics applications in recent years and shown rapid progress in static-scene measurements. Improving the adaptability on dynamic scenes is an important development direction, which calls for in-depth research on various errors caused by carrier motions. This work focuses on the error evaluation and compensation of motion-induced misalignment between the Raman laser beam and the atomic trajectory. A theoretical analysis framework is formed to investigate the atom-laser misalignment errors by considering both the inhomogeneous Raman laser intensity and wavefront phase distributions in a dynamic perspective. The influence on fringe contrast and phase shift in an atom-interferometry gravimeter is discussed. Quantitative study has been done with different motion types, motion rates as well as random motion noises. The results show oscillational decay trends of fringe contrast with the motion amplitude and the increased significance of rotationally antisymmetric Zernike terms in dynamical Raman wavefront phase shift evaluation. Strong correlations can be found between the misalignment errors and the experimental parameters. A compensation method is proposed accordingly via quickly adjusting the Raman intensity or pulse duration and comprehensive Raman wavefront characterization. Both amplitude and phase corrections are achieved. The analytical approach and results provide a practical solution for further advances of atom-interferometry under harsh motional conditions.

Applied Optics and Photonics China (AOPC)•Dec 13, 2024•0 citations

Effect of the Gaussian distribution of both atomic cloud and laser intensity in an atom gravimeter

Min-Kang Zhou, Lele Chen, Qin Luo +3 more

The mechanism of light-shift-related uncertainty in an atom-interferometry gravimeter is investigated systematically, which arises from the inhomogeneous intensity of Raman beams and the Gaussian distribution of an atomic cloud. Experiments using atom interferometry are performed to verify this systematic error by directly modulating the integration time $T$ and the intensity ratio of Raman laser beams. Using our method, the uncertainty of gravity measurements contributed by the single-photon light shift in an atom gravimeter can be corrected to a $\mathrm{sub}\ensuremath{-}\ensuremath{\mu}\mathrm{Gal}\phantom{\rule{0.28em}{0ex}}(1\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\mathrm{m}/{\mathrm{s}}^{2})$ level.

Physical Review A•May 19, 2016•17 citations

Effect of an aperture in atomic gravimetry

J. M. Cervantes, E. Gómez

There is a continuous interest in shrinking the dimensions of portable atomic gravimeters. This inevitably ends up truncating the Gaussian wings of the excitation laser beams whose effect has not been properly quantified yet. The diffraction pattern created from this aperture creates ripples in the wavefront in both the phase and the intensity. We calculate the shift in the measured value of an atomic gravimeter introduced by the phase variations in the wavefront. Fortunately, this shift has a Gaussian decay with the aperture size. For extended clouds, we observe a reduction of the effect thanks to an averaging over transverse positions with different values of the shift. Surprisingly, we found that the intensity variations also introduce an important correction to the photon recoil, which contributes at about the same level as the previous shift in the measurement of the gravitational acceleration. Our results should help decide how small an apparatus can be to guarantee a particular accuracy.

Journal of the Optical Society of America A•Apr 1, 2024•5 citations
The laser beam waist has an impact both in the sensitivity and systematic effects present in gravimetry and atom interferometry in general. In this paper we consider how different effects contribute to both aspects in order to make a better selection of the radius of the Raman beam given a particular laser power available. A large beam waist reduces systematic effects coming from wavefront curvature and Gouy phase contributions and improves the fringe contrast due to reduced intensity gradients. On the other hand, a large waist gives a smaller Rabi frequency, which lowers the sensitivity by reducing the fraction of atoms in the selected velocity range. Considering all contributions, we find that systematic effects usually have a dominant role in selecting a beam waist.
. The atom interferometry gyroscope is driven by a π/2 - π - π - π/2 Raman pulse sequence based on an atom fountain with a parabolic trajectory. The phase-locked laser beams for Raman transitions partly propagate outside of the vacuum chamber and expose to the air when passing through the two arms of the vacuum chamber. This configuration leads to the tilt of the laser's wave-front and suffers the fluctuation of air density. The impacts on both the fringe contrast and long-term stability are experimentally investigated in detail, and effective schemes are developed to improve the performance of our atom gyroscope. The method presented here could be useful for developing large atom interferometry facilities with separated vacuum chambers.
Atomic clocks provide a reproducible basis for our understanding of time and frequency. Recent demonstrations of compact optical clocks, employing thermal atomic beams, have achieved short-term fractional frequency instabilities of order ${10}^{\ensuremath{-}16}$, competitive with the best international frequency standards available. However, a serious challenge inherent in compact clocks is the necessarily smaller optical beams, which results in rapid variation in interrogating wave fronts. This can cause inhomogeneous excitation of the thermal beam leading to long-term drifts in the output frequency. Here we develop a model for Ramsey-Bord\'e interferometry using optical fields with curved wave fronts and simulate the 40Ca^{40}\mathrm{Ca}40Ca beam clock experiment described by Olson et al. [Phys. Rev. Lett. 123, 073202 (2019)]. The results of Olson et al. showed surprising and unexplained behavior in the response of the atoms in the interrogation. Our model predicts signals consistent with experimental data and can account for the significant sensitivity to laser geometry that was reported. We find the signal-to-noise ratio is maximized when the laser is uncollimated at the interrogation zones to minimize inhomogeneity and also identify an optimal waist size determined by both laser inhomogeneity and the velocity distribution of the atomic beam. We investigate the shifts and stability of the clock frequency, showing that the Gouy phase is the primary source of frequency variations arising from laser geometry.
Summary form only given. Atom interferometry based on cold atoms and light beamsplitters is a mature technique, which allows for the realization of highly sensitive inertial sensors. In the most advanced inertial sensors based on atom interferometry, atomic wavepackets are manipulated by light beamsplitters using two-photon Raman transitions. The interferometer phase shift, which depends on the acceleration and the rotation of the experimental setup with respect to the inertial reference frame defined by the atoms in free fall, is derived from the relative displacement of the atoms with respect to the beamsplitter laser's equiphases. Wavefront aberrations thus induce parasitic phase shifts, which bias the measurement, and which are linked to the residual ballistic motion of the atoms across the laser beam profile during their free fall and cancels out at zero atomic temperature. The wavefront distortions of the lasers beamsplitters is an important limit in the accuracy of atom interferometers and in particular, the dominating contribution in best cold atom gravimeters (CAG) uncertainty budget. This work clears the way towards unprecedented accuracies for absolute gravimetry, below the 1 μGal level. The method proposed can be applied to any atomic sensor based on light beamsplitters, which are inevitably affected by distortions of the lasers wavefronts. The improved control of systematics it provides will have significant impact in high precision measurements with atom interferometry, with important applications to geodesy, fundamental physics tests and to the development of highest grade inertial sensors.
Atomic gravimeter based on atom interferometry has become a hotspot of quantum optics applications in recent years and shown rapid progress in static-scene measurements. Improving the adaptability on dynamic scenes is an important development direction, which calls for in-depth research on various errors caused by carrier motions. This work focuses on the error evaluation and compensation of motion-induced misalignment between the Raman laser beam and the atomic trajectory. A theoretical analysis framework is formed to investigate the atom-laser misalignment errors by considering both the inhomogeneous Raman laser intensity and wavefront phase distributions in a dynamic perspective. The influence on fringe contrast and phase shift in an atom-interferometry gravimeter is discussed. Quantitative study has been done with different motion types, motion rates as well as random motion noises. The results show oscillational decay trends of fringe contrast with the motion amplitude and the increased significance of rotationally antisymmetric Zernike terms in dynamical Raman wavefront phase shift evaluation. Strong correlations can be found between the misalignment errors and the experimental parameters. A compensation method is proposed accordingly via quickly adjusting the Raman intensity or pulse duration and comprehensive Raman wavefront characterization. Both amplitude and phase corrections are achieved. The analytical approach and results provide a practical solution for further advances of atom-interferometry under harsh motional conditions.
The mechanism of light-shift-related uncertainty in an atom-interferometry gravimeter is investigated systematically, which arises from the inhomogeneous intensity of Raman beams and the Gaussian distribution of an atomic cloud. Experiments using atom interferometry are performed to verify this systematic error by directly modulating the integration time TTT and the intensity ratio of Raman laser beams. Using our method, the uncertainty of gravity measurements contributed by the single-photon light shift in an atom gravimeter can be corrected to a $\mathrm{sub}\ensuremath{-}\ensuremath{\mu}\mathrm{Gal}\phantom{\rule{0.28em}{0ex}}(1\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{Gal}=1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}\phantom{\rule{0.28em}{0ex}}\mathrm{m}/{\mathrm{s}}^{2})$ level.
There is a continuous interest in shrinking the dimensions of portable atomic gravimeters. This inevitably ends up truncating the Gaussian wings of the excitation laser beams whose effect has not been properly quantified yet. The diffraction pattern created from this aperture creates ripples in the wavefront in both the phase and the intensity. We calculate the shift in the measured value of an atomic gravimeter introduced by the phase variations in the wavefront. Fortunately, this shift has a Gaussian decay with the aperture size. For extended clouds, we observe a reduction of the effect thanks to an averaging over transverse positions with different values of the shift. Surprisingly, we found that the intensity variations also introduce an important correction to the photon recoil, which contributes at about the same level as the previous shift in the measurement of the gravitational acceleration. Our results should help decide how small an apparatus can be to guarantee a particular accuracy.