Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

WORLD SCIENTIFIC eBooks

ADVANCED HYBRID SQUID MULTIPLEXER CONCEPT FOR THE NEXT GENERATION OF ASTRONOMICAL INSTRUMENTS

Inseob Hahn, Peter K. Day, B. Bumble, Henry George LeDuc

Published May 1, 2009• 0 citations
Publisher

Abstract

The Superconducting Quantum Interference Device (SQUID) has been used and proposed often to read out low-temperature detectors for astronomical instruments. A multiplexed SQUID readout for currently envisioned astronomical detector arrays, which will have tens of thousands of pixels, is still challenging with the present technology. We present a new, advanced multiplexing concept and its prototype development that will allow for the readout of 1,000–10,000 detectors with only three pairs of wires and a single microwave coaxial cable.

DOI
10.1142/9789814261210_0044

Related papers

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•43 citations

Design, Fabrication, and Characterization of Microwave Multiplexing SQUID Prototype

Mengjie Song, Yixian Deng, Zhengwei Li +14 more

Abstract The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device (SQUID) multiplexer has emerged as a key technology for effectively reading large-scale cryogenic detector arrays. Currently, the microwave SQUID multiplexer is being adopted by an increasing number of experiments due to its capability of achieving a multiplexing ratio of 2000:1 within the readout bandwidth. In this study, we developed a 32-channel microwave SQUID multiplexer prototype. And we measured 8 channels of the prototype. The measured equivalent noise current of the prototype reached 154 pA/√ Hz.

arXiv:2603.29613•Journal of Low Temperature Physics•Aug 20, 2026•2 citations

Demonstration of a multiplexer of dissipationless superconducting quantum interference devices

John A. B. Mates, Gene C Hilton, K. D. Irwin +2 more

We report on the development of a microwave superconducting quantum interference device (SQUID) multiplexer to read out arrays of low-temperature detectors. In this frequency-division multiplexer, superconducting resonators with different frequencies couple to a common transmission line and each resonator couples to a different dissipationless SQUID. We demonstrate multiple designs, with high-Q values (4100–18 000), noise as low as 0.17μΦ0∕Hz, and a naturally linear readout scheme based on flux modulation. This multiplexing approach is compatible with superconducting transition-edge sensors and magnetic calorimeters and is capable of multiplexing more than a thousand detectors in a single transmission line.

Applied Physics Letters•Jan 14, 2008•162 citations

Crosstalk in microwave SQUID multiplexers

John A. B. Mates, Daniel Becker, D. A. Bennett +6 more

Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.

Applied Physics Letters•Nov 11, 2019•28 citations

Simultaneous readout of 128 X-ray and gamma-ray transition-edge microcalorimeters using microwave SQUID multiplexing

John A. B. Mates, Daniel Becker, D. A. Bennett +10 more

The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the arrays into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES) microcalorimeters contain roughly 250 detectors and use time-division multiplexing with Superconducting Quantum Interference Devices (SQUIDs). The bandwidth limits of this technology constrain the number of sensors per amplifier chain, a quantity known as the multiplexing factor, to several 10s. With microwave SQUID multiplexing, we can expand the readout bandwidth and enable much larger multiplexing factors. While microwave SQUID multiplexing of TES microcalorimeters has been previously demonstrated with small numbers of detectors, we now present a fully scalable demonstration in which 128 TES detectors are read out on a single pair of coaxial cables.

Applied Physics Letters•Aug 7, 2017•106 citations

Multiplexing technology based on SQUID for readout of superconducting transition-edge sensor arrays

Xinyu Wu, Qing Yu, Yongcheng He +2 more

Multiplexing technologies based on superconducting quantum interference devices (SQUIDs) are crucial to cryogenic readout of superconducting transition-edge sensor (TES) arrays. Demands for large-scale TES arrays promote the development of multiplexing technologies towards large multiplexing factors and low readout noise. The development of multiplexing technologies also facilitates new applications of TES arrays in a wide range of frequencies. Here we summarize different types of SQUID-based multiplexing technologies including time-division multiplexing, code-division multiplexing, frequency-division multiplexing and microwave SQUID multiplexing. The advances and parameter constraints of each multiplexing technology are also discussed.

Chinese Physics B•Apr 22, 2022•6 citations
The Superconducting Quantum Interference Device (SQUID) has been used and proposed often to read out low-temperature detectors for astronomical instruments. A multiplexed SQUID readout for currently envisioned astronomical detector arrays, which will have tens of thousands of pixels, is still challenging with the present technology. We present a new, advanced multiplexing concept and its prototype development that will allow for the readout of 1,000–10,000 detectors with only three pairs of wires and a single microwave coaxial cable.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.
Abstract The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device (SQUID) multiplexer has emerged as a key technology for effectively reading large-scale cryogenic detector arrays. Currently, the microwave SQUID multiplexer is being adopted by an increasing number of experiments due to its capability of achieving a multiplexing ratio of 2000:1 within the readout bandwidth. In this study, we developed a 32-channel microwave SQUID multiplexer prototype. And we measured 8 channels of the prototype. The measured equivalent noise current of the prototype reached 154 pA/√ Hz.
We report on the development of a microwave superconducting quantum interference device (SQUID) multiplexer to read out arrays of low-temperature detectors. In this frequency-division multiplexer, superconducting resonators with different frequencies couple to a common transmission line and each resonator couples to a different dissipationless SQUID. We demonstrate multiple designs, with high-Q values (4100–18 000), noise as low as 0.17μΦ0∕Hz, and a naturally linear readout scheme based on flux modulation. This multiplexing approach is compatible with superconducting transition-edge sensors and magnetic calorimeters and is capable of multiplexing more than a thousand detectors in a single transmission line.
Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.
The number of elements in most cryogenic sensor arrays is limited by the technology available to multiplex signals from the arrays into a smaller number of wires and readout amplifiers. The largest demonstrated arrays of transition-edge sensor (TES) microcalorimeters contain roughly 250 detectors and use time-division multiplexing with Superconducting Quantum Interference Devices (SQUIDs). The bandwidth limits of this technology constrain the number of sensors per amplifier chain, a quantity known as the multiplexing factor, to several 10s. With microwave SQUID multiplexing, we can expand the readout bandwidth and enable much larger multiplexing factors. While microwave SQUID multiplexing of TES microcalorimeters has been previously demonstrated with small numbers of detectors, we now present a fully scalable demonstration in which 128 TES detectors are read out on a single pair of coaxial cables.
Multiplexing technologies based on superconducting quantum interference devices (SQUIDs) are crucial to cryogenic readout of superconducting transition-edge sensor (TES) arrays. Demands for large-scale TES arrays promote the development of multiplexing technologies towards large multiplexing factors and low readout noise. The development of multiplexing technologies also facilitates new applications of TES arrays in a wide range of frequencies. Here we summarize different types of SQUID-based multiplexing technologies including time-division multiplexing, code-division multiplexing, frequency-division multiplexing and microwave SQUID multiplexing. The advances and parameter constraints of each multiplexing technology are also discussed.