Applied Physics Letters

Crosstalk in microwave SQUID multiplexers

John A. B. Mates, Daniel Becker, D. A. Bennett, Bradley Dober, Johnathon D. Gard, Gene C Hilton, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom

Published Nov 11, 2019• 28 citations
Publisher

Abstract

Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.

DOI
10.1063/1.5116573

Related papers

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•38 citations

Microwave SQUID multiplexer demonstration for cosmic microwave background imagers

B. Dober, D. T. Becker, D. A. Bennett +10 more

Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.

arXiv:1710.04326•Applied Physics Letters•Dec 11, 2017•58 citations

Microwave SQUID Multiplexer for Cosmic Microwave Background Imagers

Bradley Dober, Daniel Becker, D. A. Bennett +9 more

Key performance characteristics are demonstrated for the microwave SQUID multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the $\mu$MUX produces a white, input referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the $\mu$MUX as a viable readout technique for future CMB imaging instruments.

•Oct 11, 2017•0 citations

Interchannel Crosstalk and Nonlinearity of Microwave SQUID Multiplexers

Fuminori Hirayama, Tomoya Irimatsugawa, Hirotake Yamamori +9 more

In order to read out current signals from large-scale arrays of transition edge sensors (TES), microwave SQUID multiplexers (MW-MUX) have been developed by several groups. Reduction of crosstalk induced in the multiplexer is important in order to maintain the energy resolution or the noise equivalent power of detector arrays. In the present study, crosstalk between channels in MW-MUX with five different designs is experimentally evaluated. The resonance frequency separation is ten times as large as the resonator bandwidth. Without flux-ramp modulation, crosstalk between two adjacent channels neighboring in position decreases to ≈1 × 10-3with increasing resonance frequency separation to ≈100 MHz. Crosstalk between SQUID channels neighboring in resonance frequency also decreases to 4 × 10-3with increasing the distance to 2.5 mm. We show that nonlinear error can occur due to the crosstalk with flux-ramp modulation. Flux readings from a well-designed multiplexer exhibit crosstalk of less than 1 mΦ0peak-to-peak and nonlinear errors of less than 2 mΦ0peak-to-peak, which is sufficient for the readout of the gamma-ray TES arrays being developed. These results can provide guidelines for suppressing both the crosstalk and the nonlinear error to less than the criterion of TES spectrometers with typical energy-resolving ability.

IEEE Transactions on Applied Superconductivity•Dec 9, 2016•11 citations

Full-Scale Microwave SQUID Multiplexer Readout System for Magnetic Microcalorimeters

M. Neidig, Timo Muscheid, R. Gartmann +4 more

The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities. The readout of such arrays, however, presents a major challenge in terms of system complexity, parasitic heat load, and cost, which can be overcome only through multiplexing. Among the various multiplexing approaches, microwave SQUID multiplexing ($\mathrm{\mu }$MUXing) currently represents the state of the art, in particular for magnetic microcalorimeter (MMC) readout. In this work, we demonstrate the successful operation of the latest generation of our microwave SQUID multiplexer-based readout system, based on a SQUID multiplexer tailored for MMC readout and a custom full-scale software-defined radio (SDR) electronics, capable of handling up to 400 channels. We operate 14 readout channels simultaneously and demonstrate that the system operates reliably across the entire 4-8 GHz frequency band and achieves low flux white noise levels of$(1.4\pm 0.2)\,\mathrm{\upmu\Phi _{0}/\sqrt{Hz}}$in flux-ramp-demodulated readout. While technical steps regarding the SDR output power, as well as a demonstration of the simultaneous readout of the full 400 channels, remain, our results confirm that our system is fully functional and provides a scalable path towards future large-scale, high-resolution MMC experiments.

arXiv:2509.07671•IEEE Transactions on Applied Superconductivity•May 22, 2026•0 citations

Design, Fabrication, and Characterization of Microwave Multiplexing SQUID Prototype

Mengjie Song, Yixian Deng, Zhengwei Li +14 more

Abstract The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device (SQUID) multiplexer has emerged as a key technology for effectively reading large-scale cryogenic detector arrays. Currently, the microwave SQUID multiplexer is being adopted by an increasing number of experiments due to its capability of achieving a multiplexing ratio of 2000:1 within the readout bandwidth. In this study, we developed a 32-channel microwave SQUID multiplexer prototype. And we measured 8 channels of the prototype. The measured equivalent noise current of the prototype reached 154 pA/√ Hz.

arXiv:2603.29613•Journal of Low Temperature Physics•Aug 20, 2026•2 citations
Low-temperature detector technologies provide extraordinary sensitivity for applications ranging from precision measurements of the cosmic microwave background to high-resolution, high-rate x-ray, and γ-ray spectroscopy. To utilize this sensitivity, new instruments are being built, and new instruments are imagined, with ever greater pixel counts, but the scale of these instruments is limited by the capability of the readout electronics. Microwave SQUID multiplexing addresses the needs of these future instruments, exploiting gigahertz of bandwidths of coaxial cables and broadband components to combine hundreds to thousands of signals on a single readout line. A key feature of any multiplexer is the level of crosstalk between input channels. This crosstalk can degrade the sensitivity of the instrument, introduce systematic error, or simply confound data analysis. In this letter, we explain the primary mechanisms of crosstalk in a microwave SQUID multiplexer, calculate and measure their magnitude, and consider their effect and methods of mitigation.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (μ\muμMUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the μ\muμMUX produces a white, input referred current noise level of 29~pA/Hz/\sqrt{\mathrm{Hz}}/Hz​ at -77~dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure 98~pA/Hz/\sqrt{\mathrm{Hz}}/Hz​ in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e., phonon) noise. Furthermore, the power spectral density exhibits a white spectrum at low frequencies (∼\sim∼~100~mHz), which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the μ\muμMUX as a viable readout technique for future CMB imaging instruments.
In order to read out current signals from large-scale arrays of transition edge sensors (TES), microwave SQUID multiplexers (MW-MUX) have been developed by several groups. Reduction of crosstalk induced in the multiplexer is important in order to maintain the energy resolution or the noise equivalent power of detector arrays. In the present study, crosstalk between channels in MW-MUX with five different designs is experimentally evaluated. The resonance frequency separation is ten times as large as the resonator bandwidth. Without flux-ramp modulation, crosstalk between two adjacent channels neighboring in position decreases to ≈1 × 10-3with increasing resonance frequency separation to ≈100 MHz. Crosstalk between SQUID channels neighboring in resonance frequency also decreases to 4 × 10-3with increasing the distance to 2.5 mm. We show that nonlinear error can occur due to the crosstalk with flux-ramp modulation. Flux readings from a well-designed multiplexer exhibit crosstalk of less than 1 mΦ0peak-to-peak and nonlinear errors of less than 2 mΦ0peak-to-peak, which is sufficient for the readout of the gamma-ray TES arrays being developed. These results can provide guidelines for suppressing both the crosstalk and the nonlinear error to less than the criterion of TES spectrometers with typical energy-resolving ability.
The deployment of large cryogenic detector arrays, comprising hundreds to thousands of individual detectors, is highly beneficial for various cutting-edge applications, requiring large statistics, angular resolution or imaging capabilities. The readout of such arrays, however, presents a major challenge in terms of system complexity, parasitic heat load, and cost, which can be overcome only through multiplexing. Among the various multiplexing approaches, microwave SQUID multiplexing (μ\mathrm{\mu }μMUXing) currently represents the state of the art, in particular for magnetic microcalorimeter (MMC) readout. In this work, we demonstrate the successful operation of the latest generation of our microwave SQUID multiplexer-based readout system, based on a SQUID multiplexer tailored for MMC readout and a custom full-scale software-defined radio (SDR) electronics, capable of handling up to 400 channels. We operate 14 readout channels simultaneously and demonstrate that the system operates reliably across the entire 4-8 GHz frequency band and achieves low flux white noise levels of$(1.4\pm 0.2)\,\mathrm{\upmu\Phi _{0}/\sqrt{Hz}}$in flux-ramp-demodulated readout. While technical steps regarding the SDR output power, as well as a demonstration of the simultaneous readout of the full 400 channels, remain, our results confirm that our system is fully functional and provides a scalable path towards future large-scale, high-resolution MMC experiments.
Abstract The readout system with a high multiplexing ratio has become a bottleneck limiting the application of large-scale Transition Edge Sensor (TES) detector arrays. In recent years, the microwave superconducting quantum interference device (SQUID) multiplexer has emerged as a key technology for effectively reading large-scale cryogenic detector arrays. Currently, the microwave SQUID multiplexer is being adopted by an increasing number of experiments due to its capability of achieving a multiplexing ratio of 2000:1 within the readout bandwidth. In this study, we developed a 32-channel microwave SQUID multiplexer prototype. And we measured 8 channels of the prototype. The measured equivalent noise current of the prototype reached 154 pA/√ Hz.