Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development of the 1.3-1.5 THz band superconducting HEB mixer receivers for ASTE 10 m telescope

T. Shiino, Ling Jiang, Ryuta Furuya, T. Yamaguchi, Shunsuke Shiba, Takeshi Sakai, Nami Sakai, Yoshimasa Watanabe, O. Ohguchi, Hiroyuki Maezawa, T. Yamakura, Yoshihisa Irimajiri, Satoshi Yamamoto

Published Jan 1, 2011• 0 citations
OpenAlex

Related papers

Development of superconducting mixers for THz astronomy

Sheng‐Cai Shi

Science China Information Sciences•Dec 29, 2011•6 citations

A 1.3-THz Balanced Waveguide HEB Mixer for the APEX Telescope

Denis Meledin, Alexey Pavolotsky, Vincent Desmaris +13 more

In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90$\,\times\,$180$\mu{\hbox{m}}$). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light” at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s.

IEEE Transactions on Microwave Theory and Techniques•Dec 18, 2008•101 citations

A 1.4-THz Superconducting HEB Mixer for DATE5

W. Zhang, Wei Miao, Kang Zhang +1 more

Purple Mountain Observatory as well as its collaborators is proposing to build a 5-m THz telescope (DATE5) at Dome A, Antarctic. Two THz heterodyne receivers, with one at 1.4 THz, are being considered as its first generation instrument. Here we report on the development of a 1.4-THz superconducting hot-electron bolometer (HEB) mixer for DATE5, which adopts a twin-slot antenna design. The direct-detection spectral (FTS) response of the 1.4-THz superconducting HEB mixer, with the HEB device fabricated at MSPU, has been measured, giving a frequency coverage of 0.8~1.5THz. And the measured FTS response appears in good agreement with the simulated one. Preliminary noise- temperature measurement at a lower frequency of 0.85 THz shows a receiver noise temperature of 1500 K. The estimated performance at 1.4 THz should be less than 1000 K in terms of the measured FTS response. Detailed simulation and experimental results will be presented.

•Jan 1, 2012•1 citation

Integration and Characterisation of Superconducting HEB Mixers for the Herschel Space Observatory

Therese Berg

•Jan 1, 2005•0 citations

High-T c Superconducting Josephson Mixers from X- to Sub-THz Band

He Zhu, Ting Zhang, Jia Du

IEEE MTT-S International Microwave Workshop Series on Advanced Materials and Processes for RF and THz Applications (IMWS-AMP)•Jul 1, 2026•0 citations

A 1.4 THz Quasi‐Optical NbN Superconducting HEB Mixer Developed for the DATE5 Telescope

Kangmin Zhou, W. Miao, Z. Lou +7 more

In this paper, the performance of a twin-slot antenna coupled NbN superconducting HEB mixer based on a new device fabrication process is thoroughly investigated. The measured lowest double-sideband receiver noise temperature is about 600 K at 1.3 THz, and reduced to 300 K after eliminating all the quasi-optical losses. The spectral response of the HEB mixer is characterized by a Fourier Transform Spectrometer (FTS) and its calibrated spectrum is in good agreement with the simulated one. In addition, the far-field beam pattern of this HEB mixer is characterized by a near-field measurement technique. The measured results agree well with the simulations too.

IEEE Transactions on Applied Superconductivity•Dec 4, 2014•18 citations
In this paper, we report about the development, fabrication, and characterization of a balanced waveguide hot electron bolometer (HEB) receiver for the Atacama Pathfinder EXperiment telescope covering the frequency band of 1.25–1.39 THz. The receiver uses a quadrature balanced scheme and two HEB mixers, fabricated from 4- to 5-nm-thick NbN film deposited on crystalline quartz substrate with an MgO buffer layer in between. We employed a novel micromachining method to produce all-metal waveguide parts at submicrometer accuracy (the main-mode waveguide dimensions are 90$\,\times\,180180180\mu{\hbox{m}}$). We present details on the mixer design and measurement results, including receiver noise performance, stability and “first-light” at the telescope site. The receiver yields a double-sideband noise temperature averaged over the RF band below 1200 K, and outstanding stability with a spectroscopic Allan time more than 200 s.
Purple Mountain Observatory as well as its collaborators is proposing to build a 5-m THz telescope (DATE5) at Dome A, Antarctic. Two THz heterodyne receivers, with one at 1.4 THz, are being considered as its first generation instrument. Here we report on the development of a 1.4-THz superconducting hot-electron bolometer (HEB) mixer for DATE5, which adopts a twin-slot antenna design. The direct-detection spectral (FTS) response of the 1.4-THz superconducting HEB mixer, with the HEB device fabricated at MSPU, has been measured, giving a frequency coverage of 0.8~1.5THz. And the measured FTS response appears in good agreement with the simulated one. Preliminary noise- temperature measurement at a lower frequency of 0.85 THz shows a receiver noise temperature of 1500 K. The estimated performance at 1.4 THz should be less than 1000 K in terms of the measured FTS response. Detailed simulation and experimental results will be presented.
In this paper, the performance of a twin-slot antenna coupled NbN superconducting HEB mixer based on a new device fabrication process is thoroughly investigated. The measured lowest double-sideband receiver noise temperature is about 600 K at 1.3 THz, and reduced to 300 K after eliminating all the quasi-optical losses. The spectral response of the HEB mixer is characterized by a Fourier Transform Spectrometer (FTS) and its calibrated spectrum is in good agreement with the simulated one. In addition, the far-field beam pattern of this HEB mixer is characterized by a near-field measurement technique. The measured results agree well with the simulations too.