Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Quantum spatial super-resolution by the optical centroid measurement method

Shin, Чан, Chang, Boyd

Published Jan 1, 2011• 0 citations
OpenAlex

Related papers

Quantum Limits of Optical Super-Resolution

Mikhail I. Kolobov

Springer eBooks•Nov 2, 2007•4 citations

Quantum spatial super-resolution by the optical centroid measurement method

Heedeuk Shin, Kam Wai Clifford Chan, Hye Jeong Chang +1 more

We demonstrate experimentally a new procedure for obtaining spatial super-resolution in quantum imaging by measuring optical centroid. Our results show spatial resolution enhancement identical to that of quantum lithography but with higher detection efficiency.

•Jan 1, 2011•0 citations

Scalable Spatial Super-Resolution using Entangled Photons

Lee A. Rozema, J.D. Bateman, Dylan H. Mahler +4 more

We demonstrate spatial super-resolution, performing an optical centroid measurement on 4-photon N00N states with a scalable 11-detector measurement. Our results show spatial super-resolution with exponentially better detection efficiency than any previous N00N-state experiment.

•Jan 1, 2014•4 citations

Super-resolution with quantum light

Andrew Forbes, Valeria Rodríguez-Fajardo

Nature Photonics•Jan 8, 2019•3 citations

Super-resolution quantum imaging at the Heisenberg limit (Conference Presentation)

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +3 more

The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.

SPIE Quantum Technologies•May 29, 2018•0 citations

Quantum Images with Super-Resolution

Dmitriy A. Balakin, Aleksandr V. Belinsky

Journal of Russian Laser Research•Nov 1, 2015•0 citations
The method of optical centroid measurement (OCM) has shown to exhibit spatial super-resolution with enhancements at the Heisenberg limit in plane wave interference experiments. In this work, the OCM method is for the first time used in an imaging setting where actual object features are observed. The OCM result is rederived in a near-field imaging formalism for a general imaging system and in full 2-D treatment. Analogies to coherent and incoherent imaging are shown Moreover, coherent OCM imaging is experimentally implemented for photon number N = 2, where an experimental setup is presented which allows to generate the desired entangled two-photon state containing the super-resolved image. This state is then imaged by an imaging system with a finite resolution defined by its point spread function (PSF). The centroid measurement of the two-photon states delivers then an image with a width of the PSF reduced by a factor 2 corresponding to the Heisenberg limit. In the experiment, the object is illuminated by a continuous-wave pump laser centred at 405nm with an output power of 30mW. A 4-f lens system images the object to the state preparation output plane. In the far-field plane between the lenses, a 5mm long periodically poled KTiOPO4 non-linear crystal generates photon pairs at 810nm by type-0, frequency-degenerate and collinear spontaneous parametric down-conversion. This generated OCM state is then imaged by a single lens and detected in coincidence by a fully digital 2-D sensor array with single-photon sensitivity and per-pixel sub-nanosecond time resolution. The OCM state is spectrally filtered at 810nm. Its imaging capability is compared to classical light sources including spatially coherent, monochromatic illumination at 405nm and 810 nm, as well as spatially incoherent light at 810 nm. The former is implemented using collimated lasers, the latter is a thermal light source spectrally filtered at 810 nm. The PSF of the different light sources are compared at low numerical aperture by imaging a focal point of 25μm Gaussian waist radius.