IEEE/LEOS International Conference on Optical MEMS

Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov, Vishal Shah, Li‐Anne Liew, John Moreland, H. G. Robinson, Leo W. Hollberg, John E. Kitching

Published Oct 11, 2006• 2 citations
Publisher

Abstract

We demonstrate the critical subsystems of compact atomic clocks and magnetometers based on microfabricated physics packages. The clock components have a volume below 5 cm3, a fractional frequency instability below 6times10-10tau1/2, and consume 200 mW of power. The magnetometer has a sensitivity below 40pT/Hz1/2at 50 Hz
DOI
10.1109/omems.2005.1540145

Related papers

Microfabricated atomic clocks and magnetometers

Svenja A. Knappe, Peter D. D. Schwindt, Vladislav P. Gerginov +6 more

We demonstrate the critical subsystems of a compact atomic clock based on a microfabricated physics package. The clock components have a total volume below 10 cm3, a fractional frequency instability of 6 × 10−10/τ1/2, and consume 200 mW of power. The physics package is easily adapted to function as a magnetometer with sensitivity below 50 pT Hz−1/2 at 10 Hz.

Journal of Optics A Pure and Applied Optics•May 31, 2006•69 citations

Microfabricated Atomic Magnetometer

Peter D. D. Schwindt, Svenja A. Knappe, Vishal Shah +4 more

Using the techniques of microelectromechanical systems, we are developing chip-scale atomic sensors based on laser excitation of alkali atoms. Recently, we demonstrated a magnetometer physics package based on coherent population trapping that had a sensitivity of 50 pT/Hzfrac12at 10 Hz, had a volume of 12 mm3, and used 195 mW of power as presented by Schwindt et al. (2004). To improve the sensitivity and reduce the power consumption of the magnetometer, we are evaluating other methods of interrogating the atoms for use in microfabricated devices. One of these methods uses frequency modulated nonlinear magneto-optical rotation (FM NMOR). We demonstrate that an FM NMOR magnetometer can be made to self-oscillate, offering simple construction and low power consumption

Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ...•Mar 22, 2006•1 citation

A Microfabricated High Performance Magnetometer

B. J. Lindseth, Peter D. D. Schwindt, Svenja A. Knappe +4 more

We report the operation of a microfabricated atomic magnetometer using the Mx configuration. A device size of a few millimeters achieves a magnetic field noise limited sensitivity of 5.9 pT/Hz1/2 over a 1-100 Hz bandwidth.

Frontiers in Optics•Jan 1, 2006•0 citations

A Compact Physics Package of a Chip-scale Atomic Clock with a Built-in Magnetic Shield

Hyun-Gue Hong, Jongcheol Park, Tae Hyun Kim +5 more

We demonstrate a physics package for chip-scale atomic clocks in which the supporting frame itself serves as a primitive magnetic shield (~20× attenuation). It measures 4.9×4.9×4.5 mm3 with its frequency instability ~10−10 at 1 s.

Conference on Lasers and Electro-Optics•Jan 1, 2019•2 citations

Compact atomic clock based on coherent populationtrapping

J. Kitching, Leo W. Hollberg, S. Knappe +1 more

A simple, compact, low-power physics package for a vapour-cell atomic clock is described. The device measures 6.6 × 1.6 × 1.3 cm and dissipates less than 30 mW of electrical power without thermal control. The instability is 1.3 × 10-10/√[τ/(s)] for integration times τ below 100 s. Applications for this device include distributed telecommunications systems, advanced global positioning system (GPS) receivers and laboratory instrumentation.

Electronics Letters•Nov 22, 2001•56 citations

A Compact Physics Package of a Chip-Scale Atomic Clock with a Built-in Magnetic Shield

Hyun-Gue Hong, Jongcheol Park, Tae Hyun Kim +5 more

We demonstrate a physics package for chip-scale atomic clocks in which the supporting frame itself serves as a primitive magnetic shield (∼20x attenuation). It measures 4.9×4.9×4.5 mm3 with its frequency instability ∼ 10−10 at 1 s.

Conference on Lasers and Electro-Optics•May 5, 2019•2 citations
Using the techniques of microelectromechanical systems, we are developing chip-scale atomic sensors based on laser excitation of alkali atoms. Recently, we demonstrated a magnetometer physics package based on coherent population trapping that had a sensitivity of 50 pT/Hzfrac12at 10 Hz, had a volume of 12 mm3, and used 195 mW of power as presented by Schwindt et al. (2004). To improve the sensitivity and reduce the power consumption of the magnetometer, we are evaluating other methods of interrogating the atoms for use in microfabricated devices. One of these methods uses frequency modulated nonlinear magneto-optical rotation (FM NMOR). We demonstrate that an FM NMOR magnetometer can be made to self-oscillate, offering simple construction and low power consumption