Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum Electronics and Laser Science Conference

Magnetometer and frequency standard based on coherently prepared thermal alkali atomic vapors

Affolderbach, Kemp, Knappe, Nagel, Stahler, Wynands

Published Jan 1, 2000• 0 citations
OpenAlex

Related papers

A compact fiberized alkali-vapor atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

Bulletin of the American Physical Society•Jun 5, 2012•0 citations

Magnetometer Based on Single-Pass Generation in Atomic Alkali-Metal Vapors

Armen D. Sargsyan, David G. Sarkisyan

Journal of Applied Spectroscopy•Nov 1, 2025•2 citations

Magnetometer and frequency standard based on coherently prepared thermal alkali atomic vapors

C. Affolderbach, W R G Kemp, Svenja A. Knappe +3 more

Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.

Quantum Electronics and Laser Science Conference•May 7, 2000•1 citation

Atomic vapor cells with Herriott-cavity sealed under vacuum and their applications in atomic magnetometry

XIE ziping, Chuanpeng Hao, Sheng Dong

This paper focuses on standardized fabrications of atomic vapor cells with multipass cells. For this purpose, we build a vacuum system that enables the sealing of the multipass-cavity-assisted cell under vacuum. Alkali atoms are prepared inside a glass holder, and the tip of the holder is broken by controlled collisions under vacuum. Atoms are then transferred to a cell glass body part by heating. Once enough atoms accumulate inside the glass part, buffer and quenching gases are filled into the system, and the glass body part is moved to contact the silicon wafer which is bonded with a Herriott-cavity. Then the cavity part and the glass part are sealed together using the anodic bonding technique. The resulting vapor cells provide enhanced measurement sensitivity and improved device standardization, which allows for seamless replacements of each other in practical applications. The performances of these cells are tested, including a test in a double-resonance alkali-metal atomic magnetometer. A magnetic field sensitivity of 95 fT/Hz1/2 is achieved in a frequency range from 10 to 20 Hz with a multipass cell filled with 400 Torr (1 Torr = 1.33×102 Pa) N2 and natural Rb atoms at 100 ℃. The technology and cells developed in this work are expected to have wide applications in atomic devices, especially in He magnetometers and nuclear-spin atomic co-magnetometers, which have special requirements for cell qualities.

Acta Physica Sinica•Jan 1, 2025•0 citations

A novel oven structure for improving temperature uniformity of vapor cell in atomic sensors

Yanan Gao, Danyue Ma, Shuo Jiang +4 more

Alkali-metal vapor cells are key elements of atomic sensors. The temperature uniformity in the vapor cell is important for the sensitivity of the atomic sensors especially highly-sensitive SERF atomic magnetometers. This study proposes a novel double-layer cylindrical oven to improve the heating performance and the temperature uniformity of the vapor cell. We use the finite element method to build the thermal simulation models of the conventional square oven and the novel double-layer cylindrical oven. The performances of two ovens are compared. Then we build the experimental system to carry out the measurement experiment of heating temperature of the conventional and novel ovens and the in-situ measurement experiment of temperature distribution of the vapor cell using different ovens. We also measure the change of output signal amplitude of the SERF atomic magnetometer with frequency, i.e. the frequency response R(f) using the conventional and novel ovens respectively to evaluate the performance of the SERF atomic magnetometer using different ovens. The experimental results demonstrate that the proposed oven structure can improve the temperature uniformity of the alkali-metal vapor cell by 63.63% and the amplitude of R(f) using the novel oven increases by 24.7% on average. The novel double-layer cylindrical oven improves the temperature uniformity in the alkali-metal vapor cell and increases amplitude of the output signal of the SERF atomic magnetometer. The study is of great significance for improving the sensitivity of the atomic sensors especially SERF atomic magnetometers.

Results in Physics•Mar 7, 2023•22 citations

Frequency Tunable Atomic Magnetometer based on an Atom Interferometer

Frank A. Narducci, Danielle Braje, Jon P. Davis +1 more

Bulletin of the American Physical Society•Jun 4, 2013•0 citations
Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.
This paper focuses on standardized fabrications of atomic vapor cells with multipass cells. For this purpose, we build a vacuum system that enables the sealing of the multipass-cavity-assisted cell under vacuum. Alkali atoms are prepared inside a glass holder, and the tip of the holder is broken by controlled collisions under vacuum. Atoms are then transferred to a cell glass body part by heating. Once enough atoms accumulate inside the glass part, buffer and quenching gases are filled into the system, and the glass body part is moved to contact the silicon wafer which is bonded with a Herriott-cavity. Then the cavity part and the glass part are sealed together using the anodic bonding technique. The resulting vapor cells provide enhanced measurement sensitivity and improved device standardization, which allows for seamless replacements of each other in practical applications. The performances of these cells are tested, including a test in a double-resonance alkali-metal atomic magnetometer. A magnetic field sensitivity of 95 fT/Hz1/2 is achieved in a frequency range from 10 to 20 Hz with a multipass cell filled with 400 Torr (1 Torr = 1.33×102 Pa) N2 and natural Rb atoms at 100 ℃. The technology and cells developed in this work are expected to have wide applications in atomic devices, especially in He magnetometers and nuclear-spin atomic co-magnetometers, which have special requirements for cell qualities.
Alkali-metal vapor cells are key elements of atomic sensors. The temperature uniformity in the vapor cell is important for the sensitivity of the atomic sensors especially highly-sensitive SERF atomic magnetometers. This study proposes a novel double-layer cylindrical oven to improve the heating performance and the temperature uniformity of the vapor cell. We use the finite element method to build the thermal simulation models of the conventional square oven and the novel double-layer cylindrical oven. The performances of two ovens are compared. Then we build the experimental system to carry out the measurement experiment of heating temperature of the conventional and novel ovens and the in-situ measurement experiment of temperature distribution of the vapor cell using different ovens. We also measure the change of output signal amplitude of the SERF atomic magnetometer with frequency, i.e. the frequency response R(f) using the conventional and novel ovens respectively to evaluate the performance of the SERF atomic magnetometer using different ovens. The experimental results demonstrate that the proposed oven structure can improve the temperature uniformity of the alkali-metal vapor cell by 63.63% and the amplitude of R(f) using the novel oven increases by 24.7% on average. The novel double-layer cylindrical oven improves the temperature uniformity in the alkali-metal vapor cell and increases amplitude of the output signal of the SERF atomic magnetometer. The study is of great significance for improving the sensitivity of the atomic sensors especially SERF atomic magnetometers.