Precise Spectroscopy of High-Frequency Oscillating Fields with a Single-Qubit Sensor

Yaoming Chu, Pengcheng Yang, Musang Gong, Min Yu, Baiyi Yu, Martin Bodo Plenio, Alex Retzker, Jianming Cai

Published Jan 1, 2021• 8 citations
Publisher

Abstract

Precise spectroscopy of oscillating fields plays a significant role in many fields. Here, we propose an experimentally feasible scheme to measure the frequency of a fast-oscillating field using a single-qubit sensor. By invoking a stable classical clock, the signal phase correlations between successive measurements enable us to extract the target frequency with extremely high precision. In addition, we integrate dynamical decoupling technique into the framework to suppress the influence of slow environmental noise. Our framework is feasible with a variety of atomic and single solid-state spin systems within the state-of-the-art experimental capabilities as a versatile tool for quantum spectroscopy.

DOI
10.18725/oparu-44161

Related papers

Precise Spectroscopy of High-Frequency Oscillating Fields with a Single-Qubit Sensor

Yaoming Chu, Pengcheng Yang, Musang Gong +5 more

Precise spectroscopy of oscillating fields plays a significant role in many fields. Here, we propose an experimentally feasible scheme to measure the frequency of a fast-oscillating field using a single-qubit sensor. By invoking a stable classical clock, the signal phase correlations between successive measurements enable us to extract the target frequency with extremely high precision. In addition, we integrate dynamical decoupling technique into the framework to suppress the influence of slow environmental noise. Our framework is feasible with a variety of atomic and single solid-state spin systems within the state-of-the-art experimental capabilities as a versatile tool for quantum spectroscopy.

arXiv:2009.05458•Physical Review Applied•Jan 19, 2021•16 citations

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations

Accurate noise spectroscopy using quantum sensing ensembles

Dhilan T Vallury, Nikolai Dontschuk, Alexander M Jakob +2 more

Noise spectroscopy with quantum sensors is a powerful tool for characterising the properties of the sensor environment and detecting critical magnetic phenomena. While replacing single sensors with large ensembles promises substantial gains in measurement sensitivity and field of view, the output becomes difficult to interpret when there is a variable coupling to targets across the sensing ensemble. In this work we present an analysis procedure for accessing the true source noise spectrum using ensemble coherence from dynamical decoupling measurements. We show that sequence timing plays a dual role in ensemble noise spectroscopy, setting both the frequency selectivity and the weighted collection of signal across the ensemble, and demonstrate how incorporation of the coupling distribution allows accurate parameter extraction of the noise. We apply this procedure to a model system, shallow nitrogen-vacancy centres in diamond, and show that consistent information about the spectral character of MHz-range surface noise can be obtained from two sensing ensembles featuring distinct depth distributions. Our results pave the way for using large quantum sensor ensembles for quantitative, broadband noise spectroscopy, with straightforward extension to other solid-state and molecular sensing platforms.

cond-mat.mes-hallCross-listedarXiv:2609.16643•Sep 16, 2026•0 citations

High-resolution and wide-frequency-range magnetic spectroscopy with solid-state spin ensembles

Zechuan Yin, Justin J. Welter, Connor Hart +2 more

Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

npj Quantum Information•Dec 3, 2025•2 citations

Quantum spectroscopy of single spins assisted by a classical clock

Tuvia Gefen, Maxim Khodas, Liam Paul McGuinness +2 more

Quantum spectroscopy with single two-level systems has considerably improved our ability to detect weak signals. Recently it was realized that for classical signals, precision and resolution of quantum spectroscopy is limited mainly by coherence of the signal and the stability of the clock used to measure time. The coherence time of the quantum probe, which can be significantly shorter, is not a major limiting factor in resolution measurements. Here, we address a similar question for spectroscopy of quantum signals, for example, a quantum sensor is used to detect a single nuclear spin. We present and analyze a novel correlation spectroscopy technique with performance that is limited by the coherence time of the target spins and the stability of the clock.

arXiv:1612.07225•Physical Review A•Jul 27, 2018•20 citations

Narrow-bandwidth sensing of high-frequency fields with continuous dynamical decoupling

Alexander Stark, Nati Aharon, Thomas Unden +5 more

Abstract State-of-the-art methods for sensing weak AC fields are only efficient in the low frequency domain (<10 MHz). The inefficiency of sensing high-frequency signals is due to the lack of ability to use dynamical decoupling. In this paper we show that dynamical decoupling can be incorporated into high-frequency sensing schemes and by this we demonstrate that the high sensitivity achieved for low frequency can be extended to the whole spectrum. While our scheme is general and suitable to a variety of atomic and solid-state systems, we experimentally demonstrate it with the nitrogen-vacancy center in diamond. For a diamond with natural abundance of 13 C, we achieve coherence times up to 1.43 ms resulting in a smallest detectable magnetic field strength of 4 nT at 1.6 GHz. Attributed to the inherent nature of our scheme, we observe an additional increase in coherence time due to the signal itself.

arXiv:1706.04779•Nature Communications•Oct 18, 2017•76 citations
Precise spectroscopy of oscillating fields plays a significant role in many fields. Here, we propose an experimentally feasible scheme to measure the frequency of a fast-oscillating field using a single-qubit sensor. By invoking a stable classical clock, the signal phase correlations between successive measurements enable us to extract the target frequency with extremely high precision. In addition, we integrate dynamical decoupling technique into the framework to suppress the influence of slow environmental noise. Our framework is feasible with a variety of atomic and single solid-state spin systems within the state-of-the-art experimental capabilities as a versatile tool for quantum spectroscopy.
Precise spectroscopy of oscillating fields plays a significant role in many fields. Here, we propose an experimentally feasible scheme to measure the frequency of a fast-oscillating field using a single-qubit sensor. By invoking a stable classical clock, the signal phase correlations between successive measurements enable us to extract the target frequency with extremely high precision. In addition, we integrate dynamical decoupling technique into the framework to suppress the influence of slow environmental noise. Our framework is feasible with a variety of atomic and single solid-state spin systems within the state-of-the-art experimental capabilities as a versatile tool for quantum spectroscopy.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Noise spectroscopy with quantum sensors is a powerful tool for characterising the properties of the sensor environment and detecting critical magnetic phenomena. While replacing single sensors with large ensembles promises substantial gains in measurement sensitivity and field of view, the output becomes difficult to interpret when there is a variable coupling to targets across the sensing ensemble. In this work we present an analysis procedure for accessing the true source noise spectrum using ensemble coherence from dynamical decoupling measurements. We show that sequence timing plays a dual role in ensemble noise spectroscopy, setting both the frequency selectivity and the weighted collection of signal across the ensemble, and demonstrate how incorporation of the coupling distribution allows accurate parameter extraction of the noise. We apply this procedure to a model system, shallow nitrogen-vacancy centres in diamond, and show that consistent information about the spectral character of MHz-range surface noise can be obtained from two sensing ensembles featuring distinct depth distributions. Our results pave the way for using large quantum sensor ensembles for quantitative, broadband noise spectroscopy, with straightforward extension to other solid-state and molecular sensing platforms.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Quantum spectroscopy with single two-level systems has considerably improved our ability to detect weak signals. Recently it was realized that for classical signals, precision and resolution of quantum spectroscopy is limited mainly by coherence of the signal and the stability of the clock used to measure time. The coherence time of the quantum probe, which can be significantly shorter, is not a major limiting factor in resolution measurements. Here, we address a similar question for spectroscopy of quantum signals, for example, a quantum sensor is used to detect a single nuclear spin. We present and analyze a novel correlation spectroscopy technique with performance that is limited by the coherence time of the target spins and the stability of the clock.
Abstract State-of-the-art methods for sensing weak AC fields are only efficient in the low frequency domain (<10 MHz). The inefficiency of sensing high-frequency signals is due to the lack of ability to use dynamical decoupling. In this paper we show that dynamical decoupling can be incorporated into high-frequency sensing schemes and by this we demonstrate that the high sensitivity achieved for low frequency can be extended to the whole spectrum. While our scheme is general and suitable to a variety of atomic and solid-state systems, we experimentally demonstrate it with the nitrogen-vacancy center in diamond. For a diamond with natural abundance of 13 C, we achieve coherence times up to 1.43 ms resulting in a smallest detectable magnetic field strength of 4 nT at 1.6 GHz. Attributed to the inherent nature of our scheme, we observe an additional increase in coherence time due to the signal itself.