Acta Physica Sinica

Development of quantum voltage noise source chip for precision measurement of Boltzmann constant

Wang Lan-Ruo, Yuan Zhong, Jinjin Li, Qu Jifeng, Qing Zhong, Cao Wen-Hui, Wang Xue-Shen, Zhiqiang Zhou, Fu Kai, Shi Yong

Published Jan 1, 2018• 3 citations
Publisher

Abstract

The Johnson noise thermometer is used to precisely measure Boltzmann constant by comparing the thermal noise caused by charge movement and the quantized voltage reference noise synthesized by the quantum voltage noise source (QVNS). The QVNS signal is synthesized based on quantized voltage pulses produced by two channels of superconducting Josephson junction arrays, which are designed for cross-correlation electronics. The Nb/NbxSi1-x/Nb Josephson junction is used as a core device of QVNS chip in this work for its non-hysteretic current-voltage (I-V) characteristics and conveniently adjustable barrier parameters.In this paper, we present the design consideration, fabrication process, and measurement results of the QVNS chip. The QVNS chip contains two Josephson junction arrays, each consists of four 6 μm×12 μm junctions and is embedded in a 50 Ω coplanar waveguide transmission line. The random noise in signals from the two driven channels is eliminated by cross-correlation, and then an accurate quantum noise is obtained. Test chips with different areas of Josephson junctions are also designed on the same mask, aiming at estimating the variation range of Ic. The typical fabrication process for voltage standard chips in our laboratory is used for preparing the QVNS chip.The sample is measured at 4.2 K. The DC I-V curve shows that the critical current Ic is 6.1 mA. The I-V characteristics of the junctions under 5 GHz microwave radiation are measured. For a series array of four junctions, a 41.44 μV one-stage Shapiro step is observed. Calculation shows that the error between the measurement and theoretical value of 41.36 μV is about 1.9‰, which means that the QVNS chip performs well under microwave radiation and can be used for synthesizing the AC quantum voltage reference noise.A single-frequency 100 kHz sinusoidal waveform is synthesized by the QVNS chip under pulse driven signal. A spectrum of the synthesized sinusoidal waveform shows a single peak, which means that the digital pulse signal is perfectly filtered by Josephson junction arrays and the synthesized signals possess quantum accuracy. The results indicate that our chip has good dynamic response and works well in synthesizing a single-frequency AC quantum voltage signal. This work can provide core devices for the noise thermometry system and support the precise measurement of Boltzmann constant as well as redefinition of Kelvin in future. As a next step, the design and package will be further improved, and the probe module will be optimized to reduce the measurement uncertainty.

DOI
10.7498/aps.67.20172643

Related papers

Fabrication and Characterization of a Quantum Voltage Noise Source Chip for a Johnson Noise Thermometer

Yuan Zhong, Kunli Zhou, Jinjin Li +7 more

A Johnson noise thermometer (JNT) determines the thermodynamic temperature through cross-correlation measurement of the Johnson noise in a sense resistor at an unknown temperature. In the quantum voltage calibrated JNT system, a superconductive quantum voltage noise source (QVNS) is required to produce artificial pseudo-random noise to calibrate the gain of the cross-correlation electronics. In this paper, we present the design, fabrication, and characterization of the QVNS chip. Compared with our previous design, a new straightforward mirror symmetric layout is implemented. For this layout, the coplanar waveguides (CPWs) have the same lengths and transmission parameters. Equal pulse magnitudes are delivered to each Josephson junction array under the same output settings of the bipolar pattern generator. The modified QVNS chip is thereby enhanced because the quantum locking range is enlarged. A copper foil shielding package is used to eliminate crosstalk in this design. The first spectral comparison of two Josephson junction (JJ) arrays of with and without shielding is presented in this paper. The comparative results demonstrate that the shielding is effective. The abovementioned improvements enable us to synthesize both single and multitone waveforms with good spectral results, such that the chip satisfies the requirement of a QVNS-based JNT system for temperature measurements.

IEEE Access•Jan 1, 2021•1 citation

Multitone Waveform Synthesis With a Quantum Voltage Noise Source

Samuel P. Benz, Paul D. Dresselhaus, Charles J. Burroughs

We have developed a quantum voltage noise source (QVNS) based on pulse-driven Josephson arrays and optimized its waveform synthesis for use with Johnson noise thermometry (JNT). The QVNS synthesizes multitone waveforms with equal amplitude harmonic tones and random relative phases in order to characterize the amplitude-frequency response of the analog and digital electronics of the JNT system. We describe the QVNS circuit design and operation, including the lumped-array Josephson-junction circuit and the unipolar bias technique. In particular, we describe the primary design considerations that determine the voltage accuracy of the harmonic tones.

IEEE Transactions on Applied Superconductivity•Nov 17, 2010•29 citations

Characterization of programmable integrated quantum voltage noise source with variable power spectral density

Tomoya Irimatsugawa, Chiharu Urano, Takahiro Yamada

A quantum voltage noise source (QVNS) based on the Josephson effect as a reference signal is indispensable in precise Johnson noise thermometry (JNT) because it provides quantum accurate power spectral density (PSD) represented by some physical constants and design parameters. An integrated QVNS (IQVNS) device that integrates the circuit elements required for generation of a QVNS signal into one chip has been developed at AIST. The PSD of IQVNS should be variable for precise JNT measurement over a wide temperature range. Here, a new IQVNS device with variable PSD—programmable IQVNS—was developed and the values of the PSD were experimentally confirmed to be consistent with the theoretical values for various design parameters. Thus, JNT measurement over a wide temperature range can be realized with the IQVNS.

IEICE Electronics Express•Dec 20, 2021•0 citations

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations

VHF Josephson Arbitrary Waveform Synthesizer

Jeremy N. Thomas, Nathan E. Flowers-Jacobs, Anna E. Fox +3 more

We report on the design, fabrication, and measurement of a very high frequency band Josephson arbitrary waveform synthesizer (VHF-JAWS) at frequencies from 1 kHz to 50.05 MHz. The VHF-JAWS chip is composed of a series array of 12 810 Josephson junctions (JJs) embedded in a superconducting coplanar waveguide. Each JJ responds to a pattern of current pulses by creating a corresponding pattern of voltage pulses, each with a time-integrated area related to fundamental constants as${{h/2e}}$. The pulse patterns are chosen to produce quantum-based single-tone voltage waveforms with an open-circuit voltage of 50 mV rms (–19.03 dBm output power into 50$\Omega$load impedances) at frequencies up to 50.05 MHz, which is more than twice the voltage that has been generated by previous RF-JAWS designs at 1 GHz. The VHF-JAWS is “quantum-locked,” that is, it generates one quantized output voltage pulse per input current pulse per JJ while varying the dc current through the JJ array by at least 0.4 mA and the amplitude of the bias pulses by at least 10 %. We use the large bias pulse quantum-locking range to investigate one source of error in detail: the direct feedthrough of the current bias pulses into the DUT at VHF frequencies, which adds an unwanted, in-band component to the measured voltage. We reduce this error by high-pass filtering the current bias pulses and measure the error as a function of input pulse amplitude using two techniques: 1) by measuring small changes over the quantum-locking range and 2) by passively attenuating the input pulse amplitude so that the nonlinear JJs no longer generate voltage pulses while the error is only linearly scaled.

IEEE Transactions on Applied Superconductivity•Jul 1, 2024•8 citations

Quantum-Derived Voltage Waveform Synthesis With Pulse-Driven High-Transition-Temperature Josephson Junctions

Adam C. Weis, Nathan E. Flowers-Jacobs, S. J. Berkowitz +2 more

Microwave-driven Josephson junction arrays are the basis for dc and ac voltage standards, whose accuracy derives from quantized voltage pulses. These pulses are also used to synthesize voltage-noise reference signals that are used in noise thermometry systems. This article describes our recent demonstration of voltage synthesis in a high-transition-temperature YBa2Cu3O7-δjunction circuit.

IEEE Transactions on Applied Superconductivity•Jul 8, 2020•1 citation
The Johnson noise thermometer is used to precisely measure Boltzmann constant by comparing the thermal noise caused by charge movement and the quantized voltage reference noise synthesized by the quantum voltage noise source (QVNS). The QVNS signal is synthesized based on quantized voltage pulses produced by two channels of superconducting Josephson junction arrays, which are designed for cross-correlation electronics. The Nb/NbxSi1-x/Nb Josephson junction is used as a core device of QVNS chip in this work for its non-hysteretic current-voltage (I-V) characteristics and conveniently adjustable barrier parameters.In this paper, we present the design consideration, fabrication process, and measurement results of the QVNS chip. The QVNS chip contains two Josephson junction arrays, each consists of four 6 μm×12 μm junctions and is embedded in a 50 Ω coplanar waveguide transmission line. The random noise in signals from the two driven channels is eliminated by cross-correlation, and then an accurate quantum noise is obtained. Test chips with different areas of Josephson junctions are also designed on the same mask, aiming at estimating the variation range of Ic. The typical fabrication process for voltage standard chips in our laboratory is used for preparing the QVNS chip.The sample is measured at 4.2 K. The DC I-V curve shows that the critical current Ic is 6.1 mA. The I-V characteristics of the junctions under 5 GHz microwave radiation are measured. For a series array of four junctions, a 41.44 μV one-stage Shapiro step is observed. Calculation shows that the error between the measurement and theoretical value of 41.36 μV is about 1.9‰, which means that the QVNS chip performs well under microwave radiation and can be used for synthesizing the AC quantum voltage reference noise.A single-frequency 100 kHz sinusoidal waveform is synthesized by the QVNS chip under pulse driven signal. A spectrum of the synthesized sinusoidal waveform shows a single peak, which means that the digital pulse signal is perfectly filtered by Josephson junction arrays and the synthesized signals possess quantum accuracy. The results indicate that our chip has good dynamic response and works well in synthesizing a single-frequency AC quantum voltage signal. This work can provide core devices for the noise thermometry system and support the precise measurement of Boltzmann constant as well as redefinition of Kelvin in future. As a next step, the design and package will be further improved, and the probe module will be optimized to reduce the measurement uncertainty.
A Johnson noise thermometer (JNT) determines the thermodynamic temperature through cross-correlation measurement of the Johnson noise in a sense resistor at an unknown temperature. In the quantum voltage calibrated JNT system, a superconductive quantum voltage noise source (QVNS) is required to produce artificial pseudo-random noise to calibrate the gain of the cross-correlation electronics. In this paper, we present the design, fabrication, and characterization of the QVNS chip. Compared with our previous design, a new straightforward mirror symmetric layout is implemented. For this layout, the coplanar waveguides (CPWs) have the same lengths and transmission parameters. Equal pulse magnitudes are delivered to each Josephson junction array under the same output settings of the bipolar pattern generator. The modified QVNS chip is thereby enhanced because the quantum locking range is enlarged. A copper foil shielding package is used to eliminate crosstalk in this design. The first spectral comparison of two Josephson junction (JJ) arrays of with and without shielding is presented in this paper. The comparative results demonstrate that the shielding is effective. The abovementioned improvements enable us to synthesize both single and multitone waveforms with good spectral results, such that the chip satisfies the requirement of a QVNS-based JNT system for temperature measurements.
We have developed a quantum voltage noise source (QVNS) based on pulse-driven Josephson arrays and optimized its waveform synthesis for use with Johnson noise thermometry (JNT). The QVNS synthesizes multitone waveforms with equal amplitude harmonic tones and random relative phases in order to characterize the amplitude-frequency response of the analog and digital electronics of the JNT system. We describe the QVNS circuit design and operation, including the lumped-array Josephson-junction circuit and the unipolar bias technique. In particular, we describe the primary design considerations that determine the voltage accuracy of the harmonic tones.
A quantum voltage noise source (QVNS) based on the Josephson effect as a reference signal is indispensable in precise Johnson noise thermometry (JNT) because it provides quantum accurate power spectral density (PSD) represented by some physical constants and design parameters. An integrated QVNS (IQVNS) device that integrates the circuit elements required for generation of a QVNS signal into one chip has been developed at AIST. The PSD of IQVNS should be variable for precise JNT measurement over a wide temperature range. Here, a new IQVNS device with variable PSD—programmable IQVNS—was developed and the values of the PSD were experimentally confirmed to be consistent with the theoretical values for various design parameters. Thus, JNT measurement over a wide temperature range can be realized with the IQVNS.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.
We report on the design, fabrication, and measurement of a very high frequency band Josephson arbitrary waveform synthesizer (VHF-JAWS) at frequencies from 1 kHz to 50.05 MHz. The VHF-JAWS chip is composed of a series array of 12 810 Josephson junctions (JJs) embedded in a superconducting coplanar waveguide. Each JJ responds to a pattern of current pulses by creating a corresponding pattern of voltage pulses, each with a time-integrated area related to fundamental constants ash/2e{{h/2e}}h/2e. The pulse patterns are chosen to produce quantum-based single-tone voltage waveforms with an open-circuit voltage of 50 mV rms (–19.03 dBm output power into 50Ω\OmegaΩload impedances) at frequencies up to 50.05 MHz, which is more than twice the voltage that has been generated by previous RF-JAWS designs at 1 GHz. The VHF-JAWS is “quantum-locked,” that is, it generates one quantized output voltage pulse per input current pulse per JJ while varying the dc current through the JJ array by at least 0.4 mA and the amplitude of the bias pulses by at least 10 %. We use the large bias pulse quantum-locking range to investigate one source of error in detail: the direct feedthrough of the current bias pulses into the DUT at VHF frequencies, which adds an unwanted, in-band component to the measured voltage. We reduce this error by high-pass filtering the current bias pulses and measure the error as a function of input pulse amplitude using two techniques: 1) by measuring small changes over the quantum-locking range and 2) by passively attenuating the input pulse amplitude so that the nonlinear JJs no longer generate voltage pulses while the error is only linearly scaled.