Emerging Imaging and Sensing Technologies for Security and Defence; and Advanced Manufacturing Technologies for Micro- and Nanosystems in Security and Defence

Increasing the optical power in sub-shot noise precision measurements of absorption

Jonathan C. F. Matthews

Published Sep 18, 2020• 0 citations
Publisher

Abstract

The optical shot-noise limit of a laser beam represents the classical limit in precision and signal to noise ratio achievable in optical sensors and imaging systems. It is known that quantum states of light, such as squeezed light and quantum correlated twin beams can be used to enhance precision and signal to noise ratio to beyond this limit. This promises optical sensors with fundamentally superior performance to the state of the art. While quantum-enhanced signal to noise ratio has been demonstrated with macroscopic powers of squeezed probe beam, demonstrations of quantum enhanced precision have remained at extremely low powers of light (femto-Watts). Here we will give examples where increasing SNR with quantum light is not sufficient to increase precision and we will review proof of principle experiments that have demonstrated sub shot noise precision, including for absorption spectroscopy and imaging. We will also report our efforts to achieve this sub-shot-noise precision performance for transmission measurement with ~0.1mW of average probe power, equating to ~10W peak power in a pulsed experiment. Time permitting, we will discuss how integrated optics and integrated electronics enables 10s GHz bandwidth in the detection of squeezed light, for integrated quantum sensor technology.

DOI
10.1117/12.2574665

Related papers

Quantum Enhanced Precision Estimation of Transmission with Bright Squeezed Light

George S. Atkinson, Euan J. Allen, Giacomo Ferranti +2 more

Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of $0.2$ mW average ($25$ W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.

arXiv:2009.12438•Physical Review Applied•Oct 19, 2021•21 citations

Quantum Metrology with Bright Squeezed Light

George S. Atkinson

Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of $0.2$ mW average ($25$ W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.

•Dec 1, 2021•38 citations

Squeezing-enhanced heterodyne detection of 10 Hz atto-Watt optical signals

Boya Xie, Sheng Feng

A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.

Optics Letters•Dec 13, 2018•26 citations

A practical model of twin-beam experiments for sub-shot-noise absorption measurements

Jason D. Mueller, Nigam Samantaray, Jonathan C. F. Matthews

Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimental parameters such as the relative detection efficiency of the beams, uncorrelated optical noise, and uncorrelated detector noise. We show that for twin beams without excessive noise, measured correlations can be improved by increasing the detection efficiency of each beam; notwithstanding, this may unbalance detection efficiency. However, for beams with excess intensity or other experimental noise, one should balance detection efficiency, even at the cost of reducing detection efficiency—we specifically define these noise conditions and verify our results with statistical simulation. This has application in design and optimization of absorption spectroscopy and imaging experiments.

arXiv:2006.08438•Applied Physics Letters•Jul 20, 2020•7 citations

Precision Enhancement with Bright Kerr Amplitude-Squeezed Light for Static-Loss Microscopy

Cyril Torre, Rachel N. Clark, Oliver Green +5 more

For absorption imaging, optical noise is a limitation [1]. Photon counting experiments using correlated photon pair sources can achieve sub-shot noise imaging but are not scalable to high brightness [2]. While lowering the noise floor increases the signal-to-noise ratio without increasing the signal's power, enhancing the precision reduces the variance of estimates. In imaging, improved precision can lead to higher contrast images, allowing regions with similar values to be more easily distinguished due to smaller error bars [2].

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 23, 2025•0 citations

Laser Power Stabilization beyond the Shot Noise Limit Using Squeezed Light

H. Vahlbruch, D. M. Wilken, Moritz Mehmet +1 more

High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 μA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrt[Hz]. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrt[Hz] with 58 mA photocurrent measured on a single photodetector.

Physical Review Letters•Oct 22, 2018•67 citations
The optical shot-noise limit of a laser beam represents the classical limit in precision and signal to noise ratio achievable in optical sensors and imaging systems. It is known that quantum states of light, such as squeezed light and quantum correlated twin beams can be used to enhance precision and signal to noise ratio to beyond this limit. This promises optical sensors with fundamentally superior performance to the state of the art. While quantum-enhanced signal to noise ratio has been demonstrated with macroscopic powers of squeezed probe beam, demonstrations of quantum enhanced precision have remained at extremely low powers of light (femto-Watts). Here we will give examples where increasing SNR with quantum light is not sufficient to increase precision and we will review proof of principle experiments that have demonstrated sub shot noise precision, including for absorption spectroscopy and imaging. We will also report our efforts to achieve this sub-shot-noise precision performance for transmission measurement with ~0.1mW of average probe power, equating to ~10W peak power in a pulsed experiment. Time permitting, we will discuss how integrated optics and integrated electronics enables 10s GHz bandwidth in the detection of squeezed light, for integrated quantum sensor technology.
Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of 0.20.20.2 mW average (252525 W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.
Squeezed light enables measurements with sensitivity beyond the quantum noise limit (QNL) for optical techniques such as spectroscopy, gravitational wave detection, magnetometry, and imaging. Precision of a measurement---as quantified by the variance of repeated estimates---has also been enhanced beyond the QNL using squeezed light. However, sub-QNL sensitivity is not sufficient to achieve sub-QNL precision. Furthermore, demonstrations of sub-QNL precision in estimating transmission have been limited to picowatts of probe power. Here we demonstrate simultaneous enhancement of precision and sensitivity to beyond the QNL for estimating modulated transmission with a squeezed amplitude probe of 0.20.20.2 mW average (252525 W peak) power, which is 8 orders of magnitude above the power limitations of previous sub-QNL precision measurements of transmission. Our approach enables measurements that compete with the optical powers of current classical techniques, but have both improved precision and sensitivity beyond the classical limit.
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.
Quantum-intensity-correlated twin beams of light can be used to measure absorption with precision beyond the classical shot-noise limit. The degree to which this can be achieved with a given estimator is defined by the quality of the twin-beam intensity correlations, which is quantified by the noise reduction factor. We derive an analytical model of twin-beam experiments, incorporating experimental parameters such as the relative detection efficiency of the beams, uncorrelated optical noise, and uncorrelated detector noise. We show that for twin beams without excessive noise, measured correlations can be improved by increasing the detection efficiency of each beam; notwithstanding, this may unbalance detection efficiency. However, for beams with excess intensity or other experimental noise, one should balance detection efficiency, even at the cost of reducing detection efficiency—we specifically define these noise conditions and verify our results with statistical simulation. This has application in design and optimization of absorption spectroscopy and imaging experiments.
For absorption imaging, optical noise is a limitation [1]. Photon counting experiments using correlated photon pair sources can achieve sub-shot noise imaging but are not scalable to high brightness [2]. While lowering the noise floor increases the signal-to-noise ratio without increasing the signal's power, enhancing the precision reduces the variance of estimates. In imaging, improved precision can lead to higher contrast images, allowing regions with similar values to be more easily distinguished due to smaller error bars [2].
High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 μA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrt[Hz]. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrt[Hz] with 58 mA photocurrent measured on a single photodetector.