Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Optically pumped non-zero field magnetometric sensor for the magnetoencephalographic systems using intra-cavity contacted VCSELs with rhomboidal oxide current aperture

Mikhail A. Bobrov, Sergey A. Blokhin, Nikolay A. Maleev, Alexey A. Blokhin, A. P. Vasyl’ev, Alexander G. Kuzmenkov, Anatoly S. Pazgalev, Mikhail V. Petrenko, Sergei P. Dmitriev, Anton K. Vershovskii, V. M. Ustinov, I. I. Novikov, Л.Я. Карачинский

Published Dec 1, 2020• 8 citations
Publisher

Abstract

We demonstrate the possibility of using vertical-cavity surface emitting lasers with intracavity contacts and a rhomboidal oxide current aperture for creating compact optically pumped 133Cs atomic magnetometer operating in non-zero magnetic fields, which is promising to use in magnetoencephalographic systems. The magnetic resonance parameters were studied in a two-beam MX optically pumped magnetic field sensor scheme based on the effect of the magnetic resonance line narrowing at high laser pumping and high concentrations of alkali-metal atoms. The ultimate sensitivity of OPM was estimated by the ratio of the magnetic resonance steepness to the probe light shot noise level. It is shown that a magnetic sensor based on the vertical-cavity surface emitting lasers and a compact (0.125 cm3 volume) Cs vapor cell can achieve a shot noise-limited sensitivity better than 15 fT in 1 Hz bandwidth. Developed intracavity contacted VCSELs suitable for use in compact atomic magnetometers for magnetoencephalographic systems.

DOI
10.1088/1742-6596/1697/1/012175

Related papers

All-Optical Magnetometric Sensor for Magnetoencephalography and Ultralow Field Tomography

Anton K. Vershovskii, Anatoly S. Pazgalev, Mikhail V. Petrenko

Abstract A variant of the scheme of a magnetometric sensor based on cesium atomic vapor is proposed and experimentally investigated. The sensor uses magnetic resonance excitation by modulated light of an hyperfine optical pumping that is transverse to the magnetic field. It is shown that, for a cell with a volume of 0.125 cm3, the variational sensitivity of such a scheme, estimated from the ratio of the steepness of the signal in the center of the magnetic resonance to the shot noise of the detecting radiation, reaches a level of <10 fT/Hz1/2 in the frequency band width of the order of 850 Hz. The sensor, which does not emit radio frequency fields, is designed for use in magnetoencephalographic complexes. Possible ways to improve the performance of the scheme for detecting relatively fast (~4.2 kHz in a field of 0.1 mT) signals of the precession of proton magnetic moments in promising ultra-weak field tomography schemes are considered.

Technical Physics Letters•Sep 1, 2020•12 citations

Towards the Non-Zero Field Cesium Magnetic Sensor Array for Magnetoencephalography

Mikhail V. Petrenko, Sergei P. Dmitriev, Anatoly S. Pazgalev +2 more

Magnetic sensors developed for application in magnetoencephalography must meet a number of requirements; the main ones are compactness, sensitivity and response speed. We present a quantum optically pumped atomic sensor with cell volume of 0.5 cm3that meets these requirements and is operable in nonzero magnetic fields. The ultimate sensitivity of the sensor was estimated as (using the criteria of the ratio of the slope of the magnetic resonance signal to the shot noise spectral density) to be better than 5 fT/ √Hz. The actual sensitivity, measured in a gradiometric scheme, reaches 13 fT/ √Hz per sensor. We also present a novel and fast algorithm for optimization of the geometric properties of non-zero field sensor array with respect to maximization of the information transfer rate for cortical sources.

IEEE Sensors Journal•Jun 15, 2021•26 citations

Light-narrowed optically pumped Mx magnetometer with a miniaturized Cs cell

Theo Scholtes, V. Schultze, R.P.J. IJsselsteijn +2 more

We demonstrate a way of operating an optically pumped magnetometer with miniaturized cesium cell using the light-narrowing effect. The magnetometer setup shows improvement of shot-noise-limited sensitivity ($42\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in a cell of only $9.3\phantom{\rule{0.16em}{0ex}}{\mathrm{mm}}^{3}$ volume) due to the suppression of spin-exchange relaxation to a large extent and the use of a strikingly increased fraction of alkali-metal atoms for signal generation, working even in $\ensuremath{\mu}\mathrm{T}$ magnetic fields, by using only a single high-intensity laser beam both for pumping and probing of atomic spins.

Physical Review A•Oct 12, 2011•127 citations

Integration of Chip-Scale SERF Atomic Magnetometers for Magnetoencephalography Measurement

Guoliang Li, Jintang Shang, Yu Ji +2 more

This paper presents a novel scheme on the integration of chip-scale SERF magnetometer using a vertical-cavity surface-emitting laser(VCSEL) as pumping and detecting laser. The fabrication and integration process of the whole system based on stacking PCB boards consist of VCSEL, optical components, rubidium vapor cell, photo-detector, three axis Helmholtz coils. By calculation and measurement, it was found that the module is designed with a minimum output power of 0.15mW and a competitive volume of 1.4×1.4×2.5cm3. Experiments show that the sensitivity of chip-scale SERF magnetometer based on VCSEL is around 1.87pT/Hz1/2in magnetic shield environment, the integration and miniaturization design process of the magnetometer can be empolyed for magnetoencephalography(MEG) measurement.

IEEE Electronic Components and Technology Conference (ECTC)•May 1, 2018•2 citations

Bandwidth Extension Enabled by Modulated VCSEL Pumping for Quantum Sensing Application

Peng Zhou, Wei Quan, Feilong Xu +6 more

Emerging quantum sensing devices namely atomic magnetometers have become promising candidate for future biomagnetism imaging. However, the limitation of detection bandwidth exists a major drawback for devices of this kind. Conventional approaches, including transverse magnetic field modulation and close-loop control, have seen challenging tradeoffs between size, resolution and bandwidths. In this study, a wide bandwidth zero-field magnetometer with a miniaturized light source has been developed for alternating current (AC) magnetic field detection. A dual-beam Spin-Exchange Relaxation-Free (SERF) magnetometer employing a 4×4×4mm3 alkali metal vapor cell achieves a bandwidth of 188 Hz. This represents a threefold increase in bandwidth compared to non-modulated mode. The sensitivity under modulated mode demonstrated a sensitivity of 55fT/Hz1/2within the frequency range of 10-188Hz. Our results also demonstrated that the sensitivity is constrained by relaxation induced by the modulation of pumping source, so possible tradeoffs can be made based on various applications. The proposed method provides novel approach for bandwidth extension of atomic magnetometers which further pave the way for future applications including magnetoencephalography (MEG), particularly in reducing magnetic noise crosstalk and enhancing spatial resolution.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2025•3 citations

Atomic magnetometry based on the ground-state Hanle effect in an elliptically polarized light wave

D. V. Brazhnikov, A. O. Makarov, K. S. Kozlova +1 more

We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature ($\approx\,$$0.125$ cm$^3$) glass cesium vapor cell heated to a relatively low temperature of $\approx\,$$85^\circ$C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching $180$ fT/$\surd$Hz in a $200$ Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be $\approx\,$$5$ fT/$\surd$Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.

physics.atom-phCross-listedarXiv:2511.18710•The European Physical Journal D•Nov 25, 2025•0 citations
We demonstrate the possibility of using vertical-cavity surface emitting lasers with intracavity contacts and a rhomboidal oxide current aperture for creating compact optically pumped 133Cs atomic magnetometer operating in non-zero magnetic fields, which is promising to use in magnetoencephalographic systems. The magnetic resonance parameters were studied in a two-beam MX optically pumped magnetic field sensor scheme based on the effect of the magnetic resonance line narrowing at high laser pumping and high concentrations of alkali-metal atoms. The ultimate sensitivity of OPM was estimated by the ratio of the magnetic resonance steepness to the probe light shot noise level. It is shown that a magnetic sensor based on the vertical-cavity surface emitting lasers and a compact (0.125 cm3 volume) Cs vapor cell can achieve a shot noise-limited sensitivity better than 15 fT in 1 Hz bandwidth. Developed intracavity contacted VCSELs suitable for use in compact atomic magnetometers for magnetoencephalographic systems.
Abstract A variant of the scheme of a magnetometric sensor based on cesium atomic vapor is proposed and experimentally investigated. The sensor uses magnetic resonance excitation by modulated light of an hyperfine optical pumping that is transverse to the magnetic field. It is shown that, for a cell with a volume of 0.125 cm3, the variational sensitivity of such a scheme, estimated from the ratio of the steepness of the signal in the center of the magnetic resonance to the shot noise of the detecting radiation, reaches a level of <10 fT/Hz1/2 in the frequency band width of the order of 850 Hz. The sensor, which does not emit radio frequency fields, is designed for use in magnetoencephalographic complexes. Possible ways to improve the performance of the scheme for detecting relatively fast (~4.2 kHz in a field of 0.1 mT) signals of the precession of proton magnetic moments in promising ultra-weak field tomography schemes are considered.
Magnetic sensors developed for application in magnetoencephalography must meet a number of requirements; the main ones are compactness, sensitivity and response speed. We present a quantum optically pumped atomic sensor with cell volume of 0.5 cm3that meets these requirements and is operable in nonzero magnetic fields. The ultimate sensitivity of the sensor was estimated as (using the criteria of the ratio of the slope of the magnetic resonance signal to the shot noise spectral density) to be better than 5 fT/ √Hz. The actual sensitivity, measured in a gradiometric scheme, reaches 13 fT/ √Hz per sensor. We also present a novel and fast algorithm for optimization of the geometric properties of non-zero field sensor array with respect to maximization of the information transfer rate for cortical sources.
We demonstrate a way of operating an optically pumped magnetometer with miniaturized cesium cell using the light-narrowing effect. The magnetometer setup shows improvement of shot-noise-limited sensitivity (42fT/Hz42\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/\sqrt{\mathrm{Hz}}42fT/Hz​ in a cell of only 9.3mm39.3\phantom{\rule{0.16em}{0ex}}{\mathrm{mm}}^{3}9.3mm3 volume) due to the suppression of spin-exchange relaxation to a large extent and the use of a strikingly increased fraction of alkali-metal atoms for signal generation, working even in $\ensuremath{\mu}\mathrm{T}$ magnetic fields, by using only a single high-intensity laser beam both for pumping and probing of atomic spins.
This paper presents a novel scheme on the integration of chip-scale SERF magnetometer using a vertical-cavity surface-emitting laser(VCSEL) as pumping and detecting laser. The fabrication and integration process of the whole system based on stacking PCB boards consist of VCSEL, optical components, rubidium vapor cell, photo-detector, three axis Helmholtz coils. By calculation and measurement, it was found that the module is designed with a minimum output power of 0.15mW and a competitive volume of 1.4×1.4×2.5cm3. Experiments show that the sensitivity of chip-scale SERF magnetometer based on VCSEL is around 1.87pT/Hz1/2in magnetic shield environment, the integration and miniaturization design process of the magnetometer can be empolyed for magnetoencephalography(MEG) measurement.
Emerging quantum sensing devices namely atomic magnetometers have become promising candidate for future biomagnetism imaging. However, the limitation of detection bandwidth exists a major drawback for devices of this kind. Conventional approaches, including transverse magnetic field modulation and close-loop control, have seen challenging tradeoffs between size, resolution and bandwidths. In this study, a wide bandwidth zero-field magnetometer with a miniaturized light source has been developed for alternating current (AC) magnetic field detection. A dual-beam Spin-Exchange Relaxation-Free (SERF) magnetometer employing a 4×4×4mm3 alkali metal vapor cell achieves a bandwidth of 188 Hz. This represents a threefold increase in bandwidth compared to non-modulated mode. The sensitivity under modulated mode demonstrated a sensitivity of 55fT/Hz1/2within the frequency range of 10-188Hz. Our results also demonstrated that the sensitivity is constrained by relaxation induced by the modulation of pumping source, so possible tradeoffs can be made based on various applications. The proposed method provides novel approach for bandwidth extension of atomic magnetometers which further pave the way for future applications including magnetoencephalography (MEG), particularly in reducing magnetic noise crosstalk and enhancing spatial resolution.
We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave polarization when scanning the transverse magnetic field near zero. We use a miniature (≈ \approx\,≈0.1250.1250.125 cm3^33) glass cesium vapor cell heated to a relatively low temperature of ≈ \approx\,≈85∘85^\circ85∘C. Under the current experimental conditions, the sensitivity of magnetic field measurements is limited by a technical noise, reaching 180180180 fT/√\surd√Hz in a 200200200 Hz bandwidth. The ultimate photon-shot-noise-limited sensitivity of the method is estimated to be ≈ \approx\,≈555 fT/√\surd√Hz. The proposed scheme is promising for the development of a zero-field atomic magnetometer with reduced heat dissipation of the sensor head and relaxed requirements for magnetic shielding compared to counterparts operating in the spin-exchange relaxation-free regime. These features are of particular value for biomedical applications.