© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Measuring angular rotation via the rotatory dispersion effect

Chongqi Zhou, Suyi Zhong, Kaijie Ma, Yang Xu, Lixuan Shi, Yonghong He

Published Dec 22, 2020• 11 citations
Publisher

Abstract

We propose a scheme for an ultrasensitive weak measurement system with an ultrasmall rotatory dispersion effect to measure angular rotation. Estimation of angular rotation is obtained by the shift of the center wavelength. In our scheme, we obtain a continuously adjustable coupling strength and show that our system provides a 13 times higher sensitivity of 38 840 nm/rad compared with previous work. Here we demonstrate that our scheme may offer an optimal weak value ${A}_{w}$ in practice and outperforms conventional measurements in the presence of technical noise. The precision achieved by optimized weak value amplification (WVA) is about three times higher than that of a polarimeter. Our work extends the working regime of WVA. Its simplicity and robustness clear the way for widespread use of WVA involving measurements with commercial cameras and small signals.

DOI
10.1103/physreva.102.063717

Related papers

High-Precise Measurement of Optical Rotatory Dispersion Based on Weak Value Amplification

Jingyi Shao, Lan E Luo, Yu He +4 more

Chiroptical signals (generally very weak) play significant roles in chiral discrimination that bring great benefits in biochemistry, pharmacy, chemical, and so on. But, high-precise chiroptical detection is still a challenge. In this paper, a high-precise measurement of optical rotatory dispersion (ORD) based on weak value amplification (WVA) is presented. We proposed ORD detection method with parameter separation: by introducing complex coupling strength and dimensionless parameter “intensitiy contrast ratio” pointer, the ORD is only associated with the imaginary part of the weak value while circular dichroism (CD) is only associated with the real part. By designing a suitable WVA scheme, the ORD and CD can be measured separately. In the experiment, the reliability of the parameter separation method for ORD measurement is verified, and the precision reach the order of $10^{-6}$ rad. This method has a broad application prospect in biomedical sensing, medicine, chemical analysis and other fields.

IEEE photonics journal•Jul 7, 2021•15 citations

Weak-value measurements can outperform conventional measurements

Omar S. Magaña‐Loaiza, Jérémie Harris, Jeff S. Lundeen +1 more

In this paper we provide a simple, straightforward example of a specific situation in which weak-value amplification (WVA) clearly outperforms conventional measurement in determining the angular orientation of an optical component. We also offer a perspective reconciling the views of some theorists, who claim WVA to be inherently sub-optimal for parameter estimation, with the perspective of the many experimentalists and theorists who have used the procedure to successfully access otherwise elusive phenomena.

Physica Scripta•Dec 19, 2016•19 citations

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta +4 more

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

arXiv:2005.03629•Physical Review Letters•Aug 17, 2020•115 citations

Cascaded weak-value amplification for optic-fiber-based Sagnac interferometers

Jing-Hui Huang, Xiangyun Hu, Xue-Ying Duan +1 more

In this paper, we propose a scheme for angular rotation Ω measurement in an optic-fiber-based Sagnac interferometer based on cascaded weak-value amplification (CWVA). CWVA is a modified standard weak-value amplification (SWVA) technique for further enhancing temporal shifts based on the principle of the Vernier effect. By choosing the appropriate CWVA parameters and the repetition time intervals of the Vernier scale, the temporal shifts in SWVA can be further amplified by measuring the envelope shifts in CWVA. Our comprehensive simulations demonstrate that CWVA enables the detection of minuscule rotations in the range of 1.0×10 −9 rad/s≤Ω≤10×10 −9 rad/s, with significantly improved sensitivity and superior signal-to-noise ratios compared to SWVA. The enhancement with a larger detection band may have great influence on physics and related sciences, such as rotational seismology and gravitational sensing.

Journal of the Optical Society of America B•Jul 28, 2023•2 citations

Weak-Values Metrological Techniques for Parameter Estimation

Julián Martínez-Rincón

Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.

•Jan 1, 2017•0 citations

Spectrum demodulating polarimeter based on weak measurement with a phase modulation

Dongmei Li, Yonghong He, Yi Ruan +2 more

A phase modulated scheme was presented in a weak measurement based polarimeter, which was realized with spectrum demodulation for the polarization detection. According to the calculation, the phase difference between two orthogonal polarizations reveals a unique feature to enhance the weak value of the system, further optimizing the sensitivity of polarization detection. With the weak measurement in the frequency domain, the polarization angle was monitored in real time by fitting the central wavelength of the output spectrum. Applying an SBC for the phase adjustment, we demonstrated the significance of phase modification in this polarimeter theoretically and experimentally. It follows that an initial phase addition of −1.4958 rad improved the sensitivity, which was about 8.5 times higher than previous weak measurement based polarimeter. As a consequence, besides the advantages of weak measurement for optical rotation detection with spectrum demodulation, a phase modulated polarimeter with a high sensitivity exhibited great potential in investigations involving polarization detection.

Journal of Physics D Applied Physics•Sep 6, 2019•3 citations
We propose a scheme for an ultrasensitive weak measurement system with an ultrasmall rotatory dispersion effect to measure angular rotation. Estimation of angular rotation is obtained by the shift of the center wavelength. In our scheme, we obtain a continuously adjustable coupling strength and show that our system provides a 13 times higher sensitivity of 38 840 nm/rad compared with previous work. Here we demonstrate that our scheme may offer an optimal weak value Aw{A}_{w}Aw​ in practice and outperforms conventional measurements in the presence of technical noise. The precision achieved by optimized weak value amplification (WVA) is about three times higher than that of a polarimeter. Our work extends the working regime of WVA. Its simplicity and robustness clear the way for widespread use of WVA involving measurements with commercial cameras and small signals.
Chiroptical signals (generally very weak) play significant roles in chiral discrimination that bring great benefits in biochemistry, pharmacy, chemical, and so on. But, high-precise chiroptical detection is still a challenge. In this paper, a high-precise measurement of optical rotatory dispersion (ORD) based on weak value amplification (WVA) is presented. We proposed ORD detection method with parameter separation: by introducing complex coupling strength and dimensionless parameter “intensitiy contrast ratio” pointer, the ORD is only associated with the imaginary part of the weak value while circular dichroism (CD) is only associated with the real part. By designing a suitable WVA scheme, the ORD and CD can be measured separately. In the experiment, the reliability of the parameter separation method for ORD measurement is verified, and the precision reach the order of 10−610^{-6}10−6 rad. This method has a broad application prospect in biomedical sensing, medicine, chemical analysis and other fields.
In this paper we provide a simple, straightforward example of a specific situation in which weak-value amplification (WVA) clearly outperforms conventional measurement in determining the angular orientation of an optical component. We also offer a perspective reconciling the views of some theorists, who claim WVA to be inherently sub-optimal for parameter estimation, with the perspective of the many experimentalists and theorists who have used the procedure to successfully access otherwise elusive phenomena.
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.
In this paper, we propose a scheme for angular rotation Ω measurement in an optic-fiber-based Sagnac interferometer based on cascaded weak-value amplification (CWVA). CWVA is a modified standard weak-value amplification (SWVA) technique for further enhancing temporal shifts based on the principle of the Vernier effect. By choosing the appropriate CWVA parameters and the repetition time intervals of the Vernier scale, the temporal shifts in SWVA can be further amplified by measuring the envelope shifts in CWVA. Our comprehensive simulations demonstrate that CWVA enables the detection of minuscule rotations in the range of 1.0×10 −9 rad/s≤Ω≤10×10 −9 rad/s, with significantly improved sensitivity and superior signal-to-noise ratios compared to SWVA. The enhancement with a larger detection band may have great influence on physics and related sciences, such as rotational seismology and gravitational sensing.
Precision measurements are bounded by the Standard Quantum Limit, and prepar- ing non-classical states is often used to circumvent such a limit. In all cases, it is common to improve the precision in a parameter estimation procedure by averaging measurements of a large ensemble of identically prepared systems. However, such a task cannot be performed indefinitely due to sources of technical noise setting an experimental bound. Weak-Value Amplification (WVA) allows one to overcome some of these issues by amplifying a signal of interest above the technical-noise floor. This built-in robustness to external sources of noise relies on a weak coupling to a meter and postselection. In this document we evaluate, the- oretically and experimentally, under what circumstances the technique is superior to non-postselected standard techniques. We also present a novel protocol where a WVA-like response is induced in an optical homodyne-type detection technique. We dub this technique Almost-Balanced Weak Values (ABWV) and present three experimental measurements of different physical velocities to evaluate the practi- cal advantages over the well-known technique of WVA. In addition, we point out the existence of a third postselected-weak-measurements technique for metrology, Inverse Weak Value (IWV), that has been ignored by the scientific community. We use this protocol to measure ultra small tilts of a mirror in a Sagnac interfer- ometer. We report all three techniques as complementary to each other, and show their robustness for low-frequency signals.
A phase modulated scheme was presented in a weak measurement based polarimeter, which was realized with spectrum demodulation for the polarization detection. According to the calculation, the phase difference between two orthogonal polarizations reveals a unique feature to enhance the weak value of the system, further optimizing the sensitivity of polarization detection. With the weak measurement in the frequency domain, the polarization angle was monitored in real time by fitting the central wavelength of the output spectrum. Applying an SBC for the phase adjustment, we demonstrated the significance of phase modification in this polarimeter theoretically and experimentally. It follows that an initial phase addition of −1.4958 rad improved the sensitivity, which was about 8.5 times higher than previous weak measurement based polarimeter. As a consequence, besides the advantages of weak measurement for optical rotation detection with spectrum demodulation, a phase modulated polarimeter with a high sensitivity exhibited great potential in investigations involving polarization detection.