Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Generation and quantum state reconstruction of a squeezed vacuum light field resonant on the rubidium D1 line

李淑静 LI Shu-jing, Nana Zhang, Yan Hong-Mei, Xu Zhong-Xiao, Wang Hai

Published Jan 1, 2018• 2 citations
Publisher

Abstract

The squeezed light field is a kind of important continuous variable quantum resource.It has wide applications in precision measurement and quantum information processing.Quantum storage is the foundations of quantum repeater and long distance quantum communication,and alkali metal atoms are an ideal quantum storage medium due to long ground state coherent time. With the rapid development of quantum storage technology in atomic medium,the preparation of the squeezed light which resonates with alkali metal atoms has become one of the research hotspots in the field of quantum information.In this paper,we report the generation of squeezed vacuum at 795 nm (resonant on the rubidium D1 transition line) by using an optical parametric oscillation based on a periodically poled KTiOPO4 crystal. The generated squeezed light field is detected by a balanced homodyne detector,and the squeezing of-3 dB and anti-squeezing of 5.8 dB are observed at a pump power of 45 mW.By using a maximum likelihood estimation,the density matrix of the squeezed light field is reconstructed.The time-domain signals from the balanced homodyne detector are collected to acquire the noise distribution of the squeezed light under different phase angles.The likelihood function is established for the measured quadrature components.An identity matrix is chosen as an initial density matrix,and the density matrix of the squeezed field is obtained through an iterative algorithm.The diagonal elements of the density matrix denote the photon number distribution,which includes not only even photon number states but also odd photon number states.The occurrence of odd photon number states mainly comes from the system losses and the imperfect quantum efficiency of detector.The Wigner function in phase space is calculated through the density matrix,and the maximum value of the Wigner function is 0.309.The standard deviation of the squeezed component is 64.4% of that of the vacuum state,corresponding to the squeezing degree of-3.8 dB.The standard deviation of the anti-squeezing component is 1.64 times that of the vacuum state,corresponding to the anti-squeezing degree of 4.3 dB.We theoretically calculate the photon number distribution and the Wigner function of the vacuum squeezed field,and compare the results obtained by theoretical calculation with those obtained by maximum likelihood reconstruction.The probability of vacuum state|0 obtained by maximum likelihood reconstruction is greater,and the probability of photon number state|n(n=1,2,) is smaller than the corresponding theoretical calculation results.From the theoretical calculation,the maximum value of Wigner function is 0.231,and the short axis and long axis of noise range deduced from the contours of the Wigner function are larger than the results from the maximum likelihood reconstruction.The possible reasons for the discrepancy are as follows. 1) The phase scanning is nonuniform during the measurement of the quadrature components.2) The low-frequency electronic noise is not completely filtered out in the datum acquisition process.3) The datum points of measured quadrature components are not enough.In conclusion,we produce a vacuum squeezed field of 795 nm,and obtain the photon number distribution and the Wigner function in phase space through maximum likelihood estimation and theoretical calculation,respectively.This work will provide an experimental basis for generating the Schrodinger cat state.

DOI
10.7498/aps.67.20172396

Related papers

Generation of a squeezed vacuum resonant on a rubidium D1 line with periodically poled KTiOPO4

Takahito Tanimura, Daisuke Akamatsu, Yoshihiko Yokoi +2 more

We report the generation of a continuous-wave squeezed vacuum resonant on the Rb D1 line (795 nm) using periodically poled KTiOPO4 (PPKTP) crystals. With a frequency doubler and an optical parametric oscillator based on PPKTP crystals, we observed a squeezing level of -2.75+/-0.14 dB and an antisqueezing level of +7.00+/-0.13 dB. This system could be utilized for demonstrating storage and retrieval of the squeezed vacuum, which is important for the ultraprecise measurement of atomic spins as well as quantum information processing.

arXiv:quant-ph/0603214•Optics Letters•Jul 10, 2006•62 citations

Generation of bright squeezed light at 1.5 m telecommunication band and its Wigner function reconstruction

孙志妮 SUN Zhi-ni, Feng Jin-Xia, Wan Zhen-Ju +1 more

The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.

Acta Physica Sinica•Jan 1, 2016•4 citations

Generation of squeezed vacuum states by PPKTP crystal and its Wigner quasi-probability distribution function reconstruction

Chenguang Ye, Jing Zhang, 山西大学光电研究所量子光学与光量子器件国家重点实验室,太原 030006

We demonstrated experimentally the generation of squeezed vacuum by a periodically poled KTP crystal in a continuous-wave optical parametric oscillator,which was pumped with 532nm field. The squeezed vacuum of 3.41 dB at 1064 nm was detected by a homodyne detection system. Moreover,the Wigner quasi-probability distribution function of the squeezed vacuum was reconstructed using quantum tomography technique.

Acta Physica Sinica•Jan 1, 2008•7 citations

Manipulations and quantum tomography of bright squeezed states

Qinghui Li, Wenxiu Yao, Li Fan +3 more

Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.

Acta Physica Sinica•Jan 1, 2021•5 citations

Improvement of vacuum squeezing resonant on the rubidium D1 line at 795 nm

Yashuai Han, Xin Wen, Jun He +3 more

We report on efficient generation of second harmonic laser and single-mode vacuum squeezed light of 795 nm with periodically poled KTiOPO4 (PPKTP) crystals. We achieved 111 mW of ultra-violet (UV) light at 397.5 nm from 191 mW of fundamental light with a PPKTP crystal in a doubling cavity, corresponding to a conversion efficiency of 58.1%. Using the UV light to pump an optical parametric oscillator with a PPKTP crystal, we realized -5.6 dB of a maximum squeezing. We analyzed the pump power dependence of the squeezing level and concluded that the UV light induced losses limit the improvement of the squeezing level. The generated squeezed light has huge potential application in quantum memory and ultra-precise measurement.

arXiv:1601.05154•Optics Express•Jan 29, 2016•27 citations

Generation of squeezed vacuum on cesium D2 line down to kilohertz range

Jianfeng Tian, Guan-Hua Zuo, Yuchi Zhang +3 more

We report the experimental generation of a squeezed vacuum at frequencies ranging from 2.5 kHz to 200 kHz that is resonant on the cesium D2 line by using a below-threshold optical parametric oscillator (OPO). The OPO is based on a periodically-poled KTiOPO 4 (PPKTP) crystal that is pumped using a bow-tie four-mirror ring frequency doubler. The phase of the squeezed light is controlled using a quantum noise locking technique. At a pump power of 115 mW, maximum quadrature phase squeezing of 3.5 dB and anti-squeezing of 7.5 dB are detected using a home-made balanced homodyne detector. This squeezed vacuum at an atomic transition in the kilohertz range is an ideal quantum source for quantum metrology of enhancing measurement precision, especially for ultra-sensitive measurement of weak magnetic fields when using a Cs atomic magnetometer in the audio frequency range.

Chinese Physics B•Dec 1, 2017•10 citations
The squeezed light field is a kind of important continuous variable quantum resource.It has wide applications in precision measurement and quantum information processing.Quantum storage is the foundations of quantum repeater and long distance quantum communication,and alkali metal atoms are an ideal quantum storage medium due to long ground state coherent time. With the rapid development of quantum storage technology in atomic medium,the preparation of the squeezed light which resonates with alkali metal atoms has become one of the research hotspots in the field of quantum information.In this paper,we report the generation of squeezed vacuum at 795 nm (resonant on the rubidium D1 transition line) by using an optical parametric oscillation based on a periodically poled KTiOPO4 crystal. The generated squeezed light field is detected by a balanced homodyne detector,and the squeezing of-3 dB and anti-squeezing of 5.8 dB are observed at a pump power of 45 mW.By using a maximum likelihood estimation,the density matrix of the squeezed light field is reconstructed.The time-domain signals from the balanced homodyne detector are collected to acquire the noise distribution of the squeezed light under different phase angles.The likelihood function is established for the measured quadrature components.An identity matrix is chosen as an initial density matrix,and the density matrix of the squeezed field is obtained through an iterative algorithm.The diagonal elements of the density matrix denote the photon number distribution,which includes not only even photon number states but also odd photon number states.The occurrence of odd photon number states mainly comes from the system losses and the imperfect quantum efficiency of detector.The Wigner function in phase space is calculated through the density matrix,and the maximum value of the Wigner function is 0.309.The standard deviation of the squeezed component is 64.4% of that of the vacuum state,corresponding to the squeezing degree of-3.8 dB.The standard deviation of the anti-squeezing component is 1.64 times that of the vacuum state,corresponding to the anti-squeezing degree of 4.3 dB.We theoretically calculate the photon number distribution and the Wigner function of the vacuum squeezed field,and compare the results obtained by theoretical calculation with those obtained by maximum likelihood reconstruction.The probability of vacuum state|0 obtained by maximum likelihood reconstruction is greater,and the probability of photon number state|n(n=1,2,) is smaller than the corresponding theoretical calculation results.From the theoretical calculation,the maximum value of Wigner function is 0.231,and the short axis and long axis of noise range deduced from the contours of the Wigner function are larger than the results from the maximum likelihood reconstruction.The possible reasons for the discrepancy are as follows. 1) The phase scanning is nonuniform during the measurement of the quadrature components.2) The low-frequency electronic noise is not completely filtered out in the datum acquisition process.3) The datum points of measured quadrature components are not enough.In conclusion,we produce a vacuum squeezed field of 795 nm,and obtain the photon number distribution and the Wigner function in phase space through maximum likelihood estimation and theoretical calculation,respectively.This work will provide an experimental basis for generating the Schrodinger cat state.
We report the generation of a continuous-wave squeezed vacuum resonant on the Rb D1 line (795 nm) using periodically poled KTiOPO4 (PPKTP) crystals. With a frequency doubler and an optical parametric oscillator based on PPKTP crystals, we observed a squeezing level of -2.75+/-0.14 dB and an antisqueezing level of +7.00+/-0.13 dB. This system could be utilized for demonstrating storage and retrieval of the squeezed vacuum, which is important for the ultraprecise measurement of atomic spins as well as quantum information processing.
The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.
Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.
We report on efficient generation of second harmonic laser and single-mode vacuum squeezed light of 795 nm with periodically poled KTiOPO4 (PPKTP) crystals. We achieved 111 mW of ultra-violet (UV) light at 397.5 nm from 191 mW of fundamental light with a PPKTP crystal in a doubling cavity, corresponding to a conversion efficiency of 58.1%. Using the UV light to pump an optical parametric oscillator with a PPKTP crystal, we realized -5.6 dB of a maximum squeezing. We analyzed the pump power dependence of the squeezing level and concluded that the UV light induced losses limit the improvement of the squeezing level. The generated squeezed light has huge potential application in quantum memory and ultra-precise measurement.
We report the experimental generation of a squeezed vacuum at frequencies ranging from 2.5 kHz to 200 kHz that is resonant on the cesium D2 line by using a below-threshold optical parametric oscillator (OPO). The OPO is based on a periodically-poled KTiOPO 4 (PPKTP) crystal that is pumped using a bow-tie four-mirror ring frequency doubler. The phase of the squeezed light is controlled using a quantum noise locking technique. At a pump power of 115 mW, maximum quadrature phase squeezing of 3.5 dB and anti-squeezing of 7.5 dB are detected using a home-made balanced homodyne detector. This squeezed vacuum at an atomic transition in the kilohertz range is an ideal quantum source for quantum metrology of enhancing measurement precision, especially for ultra-sensitive measurement of weak magnetic fields when using a Cs atomic magnetometer in the audio frequency range.