The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.
The squeezed light at 1.5 m telecommunication band has been considered as an important resource of continuous variable (CV) practical fiber-based quantum information research because it is the lowest loss in fiber. A bright phase quadrature squeezed light for continuous variable at 1.5 m is demonstrated from a semi-monolithic degenerate optical parametric amplifier (DOPA) based on a periodically poled KTiOPO4 (PPKTP) crystal. The laser source is a continuous wave (CW) single-frequency fiber laser at 1.5 m, which is sent through a ring mode cleaner (MC) as a preliminary spatial and noise filter. And then the main portion of the output from the MC is used for external-enhanced second harmonic generation to obtain a CW single-frequency low noise laser at 780 nm that acts as the pump of the DOPA. The residual light of the output from the MC at 1.5 m is used as the injected signal light of the DOPA and the local oscillator (LO) of a balanced homodyne detector (BHD) system. The DOPA is built by using a type-I PPKTP crystal and a piezo-actuated output coupler and works in double-resonance case with a threshold power of 230 mW. When the DOPA is operating in the state of amplification, the output down-conversion field should be a bright phase quadrature squeezed light, where the relative phase between the pump and the injected signal is locked to 0. A 4.7 dB bright phase quadrature squeezed light is measured by the BHD system with the pump light of 110 mW and the injected signal of 3 mW, where the relative phase between the down-conversion field and the LO is locked to 0. Our measurement is limited by the optical losses and the detection efficiency. We have taken into account the detection efficiency of 86.6%, and the actual squeezing of the squeezed light being 6.3 dB. Moreover, because it is so crucial a process for CV quantum information system that the transmission and evolution of the CV squeezed states in the fiber may reappear in all information of the quantum states in the phase space, then the bright squeezed light is detected by a BHD system in the time domain, and its Wigner quasi-probability distribution function can be reconstructed by using a quantum tomographic technique. Furthermore, the bright squeezed state at 1.5 m is an ideal source for fiber-based long-distance quantum information because of its stability and bright mean field.
Continuous variable (CV) audio-band frequency squeezed states at the fiber telecommunication wavelength is an important quantum resource for the practical applications based on optical fiber. As is well known, the optical power attenuation and phase diffusion effect of light at 1.3 μm in standard telecommunication fibres are low and small, respectively. The audio-band frequency squeezed light at 1.34 μm can be utilized to realize quantum precision measurement, such as quantum-enhanced sensing in the low-frequency range, laser interferometer for gravitational wave detection. In this paper, CV audio-band frequency vacuum squeezed states at 1.3 μm are experimentally generated by using a type-I degenerate optical parametric oscillator (DOPO) below the threshold. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1.34 μm) Nd:YVO4/LBO laser is used as a pump source for DOPO based on a type-I quasi-phase-matched periodically poled KTiOPO4 (PPKTP) crystal. Mode cleaners with a finesse of 400 and linewidth of 0.75 MHz are used to filter the noise of lasers at 671 nm and 1.34 μm, respectively. The intensity noises of the two lasers reach a shot noise level for analysis frequencies higher than 1.0 MHz and their phase noises reach shot noise level for analysis frequencies higher than 1.3 MHz, respectively. The low noise single-frequency 671 nm laser is utilized as a pump of the DOPO. The threshold power of the DOPO is 450 mW. In order to detect the audio-band frequency vacuum squeezed states, the power of local oscillator of a homodyne detector system is optimized to 60 μupW. Furthermore, the effect of common mode rejection ratio (CMRR) of detectors is discussed in detecting the audio-band frequency vacuum squeezed states. Improvement of CMRR of detectors is a good way to detect the audio-band frequency vacuum squeezed states effectively. When the phase matching temperature of PPKTP crystal is controlled at 53℃ by using a home-made temperature controller and the pump power is 95 mW, the vacuum squeezed states are generated at analysis frequency ranging from 8-100 kHz. A maximum measured squeeze of 5.0 dB is obtained at analysis frequency of 36 kHz. A 3.0 dB squeezed light is obtained at an audio-band frequency of 8 kHz.
Generation and manipulation of continuous variable quantum states are the building blocks of quantum communication, quantum key distribution and quantum networks. According to the second-order nonlinear process of the periodically-poled potassium titanyl phosphate (PPKTP) crystal, we design a semi-monolithic optical parametric amplifier (OPA) cavity to generate the bright squeezed light at a wavelength of 1064 nm. With the injection of a seed beam, the squeezed state generated by the OPA has a coherent amplitude, so called bright squeezed state. The squeezing level is directly observed to be –11.6 dB when the pump power is 310 mW at an analysis frequency of 3 MHz. However, with the increase of the pump power, the purity of the squeezed state gets lower and lower due to the increased influence of the anti-squeezing quadrature component on the squeezed quadrature component in the detection process. To obtain a higher purity of the squeezed state for achieving linear optical manipulation and quantum tomography, we choose the pump power of 50 mW, the squeezing level decreases to –6 dB, and the purity of the squeezed state is 98.5% in this case. An electro-optic modulator is adopted to realize the liner manipulation of the squeezed light in the phase space. During the measurement of the bright squeezed state, all the data are taken on condition that the length of the OPA cavity and relative phase between the seed beam and the pump beam are locked by a locking loop. The direct current (DC) signal of the balanced homodyne detection (BHD) is used to accurately determine the phase corresponding to the time domain signal of the squeezed state, while the alternate current (AC) signal of the BHD is mixed with the signal generated by the function generator, after passing through a low-pass filter and a high-pass filter, the signal is then amplified by using a low-noise amplifier. A high-performance oscilloscope is finally used to simultaneously collect the signals, thus obtaining the quantum noise signal of the bright squeezed light after linear manipulation. Together with the maximum likelihood estimation algorithm, the quantum tomography, the density matrix and the Wigner function of the bright squeezed light are obtained, that is, all the information such as the photon number distribution of the quantum state is determined. Multiple iterations are taken in the maximum likelihood estimation algorithm process to eliminate the influence of the low quantum efficiency on the detection system, so that the density matrix is fitted well with the theoretical results.
Continuous variable (CV) quantum entanglement is a fundamental resource of CV quantum communication and quantum computation. It is useful in a wide variety of applications, including quantum teleportation, quantum dense coding, quantum key distribution, and high-precision quantum measurement. In this paper, we generate CV quantum entanglement at a telecommunication wavelength of 1342 nm by using a nondegenerate optical parametric amplifier (NOPA) with a type-Ⅱ periodically poled KTiOPO4 (PPKTP) crystal. A home-made continuous-wave single-frequency dual-wavelength (671 nm and 1342 nm) Nd:YVO4/LiB3O5 laser is achieved with output powers of 1.5 W (671 nm) and 1.3 W (1342 nm). Then a mode cleaner (MC1) with a fineness of 400 and linewidth of 0.75 MHz and a mode cleaner MC2 with a fineness of 400 and linewidth of 0.75 MHz are used to filter the noises of laser at 1342 nm and 671 nm, respectively. By using MCs, the intensity noise of laser reaches a shot noise level (SNL) for analysis frequencies higher than 1.0 MHz, and the phase noise of laser reaches an SNL for analysis frequencies higher than 1.3 MHz. Utilizing this kind of low noise single-frequency 671 nm laser as a pump, a doubly-resonant optical parametric oscillator with a threshold of 325 mW is realised. When the low noise single-frequency 1342 nm laser is injected as a signal and the relative phase between the pump and injected signal is locked to , the NOPA is operated at deamplification. After optimizing the temperature of the type-Ⅱ PPKTP crystal and at a pump power of 260 mW, Einstein-Podolsky-Rosen (EPR)-entangled beams with quantum correlation of 3.0 dB for both the amplitude and phase quadratures are experimentally generated. The strength of EPR-entangled beams is relatively low. It is maybe due to the low nonlinear conversion efficiency and large absorption of the type-Ⅱ PPKTP crystal at 671 nm and 1342 nm. The generated CV quantum entanglement at 1.34 m has lower transmission loss and smaller phase diffusion effect in a silica fiber. The research contributes to a high quality quantum source for the CV quantum communication based on existing telecommunication fiber networks.
The use of optical sensing for in vivo applications is compelling, since it offers the advantages of non-invasiveness, non-ionizing radiation, and real-time monitoring. However, the signal-to-noise ratio (SNR) of the optical signal deteriorates dramatically as the biological tissue increases. Although increasing laser power can improve the SNR, intense lasers can severely disturb biological processes and viability. Quantum sensing with bright squeezed light can make the measurement sensitivity break through the quantum noise limit under weak laser conditions. A bright squeezed light source is demonstrated to avoid the deterioration of SNR and biological damage, which integrates an external cavity frequency-doubled laser, a semi-monolithic standing cavity with periodically poled titanyl phosphate (PPKTP), and a balanced homodyne detector (BHD) assembled on a dedicated breadboard. With the rational design of the mechanical elements, the optical layout, and the feedback control equipment, a maximum non-classical noise reduction of −10.7 ± 0.2 dB is observed. The average squeeze of −10 ± 0.2 dB in continuous operation for 60 min is demonstrated. Finally, the intracavity loss of degenerate optical parametric amplifier (DOPA) and the initial bright squeezed light can be calculated to be 0.0021 and −15.5 ± 0.2 dB, respectively. Through the above experimental and theoretical analysis, the direction of improving bright squeeze level is pointed out.
Generation of squeezed state at telecommunication wavelength has been recently a very interesting issue due to the lowest optical power attenuation of light at a wavelength of 1550 nm in a standard telecommunication fiber. The low-frequency vacuum squeezed state at 1550 nm in combination with fiber based interferometer offers the possibility to implement quantum precision measurement beyond standard quantum limit (SQL). In this paper, we experimentally realize a quantum-enhanced fiber Mach-Zehnder interferometer (FMZI) for measuring the low-frequency phase modulation signal by using low-frequency vacuum squeezing at 1550 nm. Firstly, the low-frequency vacuum squeezed state at the telecommunication wavelength of 1550 nm is generated by using a degenerate optical parametric oscillator (DOPO). The DOPO is a semi-monolithic construction based on a type I periodically poled KTiOPO4 (PPKTP) crystal and a concave mirror. The pump threshold of DOPO is 270 mW. When the pump power is 120 mW that is below the pump threshold of DOPO and the temperature of PPKTP is controlled at 34.8℃, a vacuum squeezing of 3 dB is generated at an analysis frequency range from 10 kHz to 500 kHz. The quadrature phase vacuum squeezing is obtained by locking the squeezed quadrature angle through using a coherent control scheme, in which two acousto-optic modulators are used to shift the frequency and produce the auxiliary beam acting as a coherent control field. Based on the constructed FMZI, a quantum-enhanced FMZI is realized by injecting the generated low-frequency vacuum squeezed state at 1550 nm into the vacuum channel of FMZI. The relative phase between two injected light fields is locked at π by using the Pound-Drever-Hall (PDH) locking technology, and the relative phase between light fields of its arms in FMZI is also locked at π/2 by using the PDH locking technology. When a phase modulation signal at the frequency of 500 kHz is loaded in the signal arm of FMZI, the noise power spectrum of the output from FMZI is measured by a balance homodyne detect system. A 2 dB quantum improvement beyond shot-noise-level at the frequency of 500 kHz is obtained experimentally by using the quantum-enhanced FMZI. The experimental results demonstrate a potential application in quantum precision measurement beyond the SQL based on fiber sensor technique.
The squeezed light field is a kind of important continuous variable quantum resource.It has wide applications in precision measurement and quantum information processing.Quantum storage is the foundations of quantum repeater and long distance quantum communication,and alkali metal atoms are an ideal quantum storage medium due to long ground state coherent time. With the rapid development of quantum storage technology in atomic medium,the preparation of the squeezed light which resonates with alkali metal atoms has become one of the research hotspots in the field of quantum information.In this paper,we report the generation of squeezed vacuum at 795 nm (resonant on the rubidium D1 transition line) by using an optical parametric oscillation based on a periodically poled KTiOPO4 crystal. The generated squeezed light field is detected by a balanced homodyne detector,and the squeezing of-3 dB and anti-squeezing of 5.8 dB are observed at a pump power of 45 mW.By using a maximum likelihood estimation,the density matrix of the squeezed light field is reconstructed.The time-domain signals from the balanced homodyne detector are collected to acquire the noise distribution of the squeezed light under different phase angles.The likelihood function is established for the measured quadrature components.An identity matrix is chosen as an initial density matrix,and the density matrix of the squeezed field is obtained through an iterative algorithm.The diagonal elements of the density matrix denote the photon number distribution,which includes not only even photon number states but also odd photon number states.The occurrence of odd photon number states mainly comes from the system losses and the imperfect quantum efficiency of detector.The Wigner function in phase space is calculated through the density matrix,and the maximum value of the Wigner function is 0.309.The standard deviation of the squeezed component is 64.4% of that of the vacuum state,corresponding to the squeezing degree of-3.8 dB.The standard deviation of the anti-squeezing component is 1.64 times that of the vacuum state,corresponding to the anti-squeezing degree of 4.3 dB.We theoretically calculate the photon number distribution and the Wigner function of the vacuum squeezed field,and compare the results obtained by theoretical calculation with those obtained by maximum likelihood reconstruction.The probability of vacuum state|0 obtained by maximum likelihood reconstruction is greater,and the probability of photon number state|n(n=1,2,) is smaller than the corresponding theoretical calculation results.From the theoretical calculation,the maximum value of Wigner function is 0.231,and the short axis and long axis of noise range deduced from the contours of the Wigner function are larger than the results from the maximum likelihood reconstruction.The possible reasons for the discrepancy are as follows. 1) The phase scanning is nonuniform during the measurement of the quadrature components.2) The low-frequency electronic noise is not completely filtered out in the datum acquisition process.3) The datum points of measured quadrature components are not enough.In conclusion,we produce a vacuum squeezed field of 795 nm,and obtain the photon number distribution and the Wigner function in phase space through maximum likelihood estimation and theoretical calculation,respectively.This work will provide an experimental basis for generating the Schrodinger cat state.