From 1 April 2019 to 27 March 2020, the Advanced Virgo detector, together with the two Advanced LIGO detectors, conducted the third joint scientific observation run O3, aiming for further detections of gravitational wave signals from astrophysical sources. One of the upgrades to the Virgo detector for O3 was the implementation of the squeezed light technology to improve the detector sensitivity beyond its classical quantum shot noise limit. In this paper, we present a detailed description of the optical setup and performance of the employed squeezed light source. The squeezer was constructed as an independent, stand-alone sub-system operated in air. The generated squeezed states are tailored to exhibit high purity at intermediate squeezing levels in order to significantly reduce the interferometer shot noise level while keeping the correlated enhancement of quantum radiation pressure noise just below the actual remaining technical noise in the Advanced Virgo detector.
From 1 April 2019 to 27 March 2020, the Advanced Virgo detector, together with the two Advanced LIGO detectors, conducted the third joint scientific observation run O3, aiming for further detections of gravitational wave signals from astrophysical sources. One of the upgrades to the Virgo detector for O3 was the implementation of the squeezed light technology to improve the detector sensitivity beyond its classical quantum shot noise limit. In this paper, we present a detailed description of the optical setup and performance of the employed squeezed light source. The squeezer was constructed as an independent, stand-alone sub-system operated in air. The generated squeezed states are tailored to exhibit high purity at intermediate squeezing levels in order to significantly reduce the interferometer shot noise level while keeping the correlated enhancement of quantum radiation pressure noise just below the actual remaining technical noise in the Advanced Virgo detector.
Current interferometric gravitational-wave detectors are limited by quantum noise over a wide range of their measurement bandwidth. One method to overcome the quantum limit is the injection of squeezed vacuum states of light into the interferometer's dark port. Here, we report on the successful application of this quantum technology to improve the shot noise limited sensitivity of the Advanced Virgo gravitational-wave detector. A sensitivity enhancement of up to 3.2±0.1 dB beyond the shot noise limit is achieved. This nonclassical improvement corresponds to a 5%-8% increase of the binary neutron star horizon. The squeezing injection was fully automated and over the first 5 months of the third joint LIGO-Virgo observation run O3 squeezing was applied for more than 99% of the science time. During this period several gravitational-wave candidates have been recorded.
A century after the prediction of the existence of gravitational waves by A. Einstein and after over fifty years of experimental efforts, gravitational waves have been detected at Earth directly. This result is a major achievement and opens new prospectives for the exploration of our universe. Gravitational waves carry different and complementary information about the source with respect to electromagnetic signals. In particular the first detection demonstrated the existence of stellar-mass black holes, binary systems of black holes and their coalescence. The detection was made by the LIGO instruments which are twin kilometer-scale Michelson interferometers in the US. These detectors represent the second generation of gravitational wave interferometers and, for the first time, they achieved the outstanding strain sensitivity of 10^(-23) Hz^(-1/2) between 90Hz and 400Hz. In the next months the LIGO network will be joined by another second generation detector: Advanced Virgo located near Pisa, Italy. The sensitivity of these advanced detectors is set by different noise sources. In particular, in the low frequency range (below 100Hz) major contributions come from thermal noises, gravity gradient noise and radiation pressure noise; instead, the high frequency band (above 100-200Hz) is dominated by shot noise. Quantum noise (radiation pressure and shot noise) is expected to dominate the detector sensitivity in the whole frequency band at the final target laser input power. To decrease the shot noise while increasing the radiation-pressure noise, or vice-versa, Caves \cite{Caves1981} proposed in 1981 the idea of the squeezed-state technique. The LIGO collaboration demonstrated for the first time in 2011 that the injection of a squeezed vacuum state into the dark port of the interferometer can reduce the shot noise due to the quantum nature of light. This result was achieved with the German-British interferometer GEO600 and was replicated in 2013 with the LIGO interferometer at Livingston. After these results, the LIGO collaboration have pursued further the research in the squeezed-state technique which is considered mandatory for third generation of ground based interferometric detectors. In 2013, the Virgo collaboration started developing the squeezed-state technique. The subject of my thesis is the realization of a prototype of frequency independent squeezed vacuum state source to be injected in Advanced Virgo. This prototype is developed in collaboration with other Virgo groups.
The era of gravitational-wave astronomy has begun, with the detection of 5 confirmed binary black holes and a binary neutron star coalescence by the Advanced Laser Interferometer Gravitational- wave Observatory (aLIGO), and later with the advanced Virgo detector. These detections have already revealed a wealth of discoveries across the fields of nuclear physics, general relativity and astrophysics. The work presented in this thesis is part of the ongoing effort to improve the sensitivity of ground-based interferometric gravitational-wave detectors. The sensitivity of aLIGO, and other interferometric detectors, is broadly limited by quantum noise. Improving on the quantum noise will increase the astrophysical range of the detectors, and improve the source parameter estimation. One way to reduce quantum noise is to inject audio- band squeezed vacuum states into the detection port. This technique has been demonstrated on the initial LIGO and GEO600 detectors. A squeezed light source for aLIGO must meet stringent requirements in terms of optical loss, phase noise, and scattered light. The squeezer must produce high levels of audio-band squeezing and operate under vacuum, to take advantage of the excellent existing isolation systems and to minimise optical loss. At design sensitivity, squeezed states whose quantum noise depends on frequency will be required. We have demonstrated an ultra-stable glass-based squeezed light source, the first experiment of this kind to operate under vacuum. The squeezer cavity is constructed quasi-monolithically, with optics and nonlinear crystal oven optically contacted to a breadboard base. The cavity is designed to have extremely low length noise, and to produce high levels of audio-band squeezing. We have measured 8.6 ± 0.9 dB of squeezing and infer the generation of 14.2 ± 1.0 dB after accounting for all known losses. The squeezer has demonstrated record phase noise performance of 1.3 mradRMS, dominated by sources other than cavity length noise. This exceeds the phase-noise requirement for a squeezer for aLIGO. A copy of this squeezer is currently being installed in a squeezing- ellipse rotation experiment to demonstrate frequency-dependent squeezing for aLIGO. Lessons learnt during the construction and operation of the in-vacuum squeezer have helped inform the design of a frequency-independent squeezed light source currently being installed at the LIGO sites. Future gravitational-wave detectors will continue to use interferometric techniques, and will be limited by quantum noise for the foreseeable future. To improve on thermal noise limits and interferometer power handling, future detectors look to cryogenic silicon as a test mass material. To take advantage of the desirable properties of silicon, including low scatter and absorption, a longer operating wavelength is required. The proposed LIGO Voyager upgrade has an operating wavelength in the 2 μ m region, with the specific wavelength to be determined. LIGO Voyager will require a squeezed light source in the 2 μ m region to reach its design sensitivity. We present the design, characterisation, and results of the first squeezed light source in the 2 μ m region. Laser and detector technologies at 2 μ m are less developed than their 1064 nm counterparts, causing significant technical challenges. We have measured 4.0 ± 0.2 dB of squeez- ing at 1984 nm, limited by loss due to detector quantum efficiency. Accounting for known losses in the system, we infer the generation of 10 dB of squeezing. This is an important demonstra- tion of quantum noise reduction for future detectors, and a pathfinder technology for the design choices of LIGO Voyager. So far we have found no reason why a 2 μ m interferometer should not be feasible.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects the beam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
Current gravitational wave detectors, such as LIGO, Virgo and KAGRA, are laser interferometers. This technique consists of injecting a laser beam through an input port, which is then separated into two arms several kilometers long by a semi-reflecting mirror. At the end of each arm, a mirror reflects thebeam back to the semi-reflecting mirror. The two beams then interfere and the power of the resulting beam, measured at the detection port, contains information about the relative length of the two arms. When a gravitational wave passes through the detector, this relative length varies in time. Several noise sources degrade the quality of the recorded signal, which affects the number of gravitational waves that can be observed. Currently, this sensitivity is limited at high-frequency by the quantum noise.An electromagnetic wave described by quantum mechanics has a classical amplitude and quantum fluctuations in amplitude and phase. A state with a null classical amplitude is called a vacuum state, but still has these quantum fluctuations. Thus, in the detector, although no light beam is introduced through the detection port, the vacuum state is present. It is then the quantum fluctuations of this vacuum state that are responsible for the quantum noise of the interferometer. In particular, the phase and amplitude fluctuations are respectively responsible for the quantum noise at high and low frequencies; the separation between these two regions occurs at about 100 Hz.The work presented in this thesis focuses on the injection of squeezed vacuum states into the Virgo detector via the detection port in order to lower the quantum noise. These states are characterized by the fact that their phase (amplitude) fluctuations are reduced, which allows reducing the quantum noise at high (low) frequency. As the Virgo detector is currently limited only by high-frequency quantum noise, only phase squeezed vacuum states were used during the last observation period O3. It was first necessary to ensure that these squeezed vacuum states had the proper geometric and phase parameters with respect to the interferometer beam such that they were not degraded. Control loops allowed these parameters to be maintained at their nominal values during O3, a year long period. The decrease in high-frequency quantum noise, but also the increase in low-frequency quantum noise, have been measured for the first time with the Virgo detector. These observations were in agreement with the measurements of the losses that affect the squeezed vacuum states.From O4 , quantum noise will also be limiting at low frequency. It will then be possible to use squeezed vacuum states having their amplitude fluctuations reduced at low frequency and their phase fluctuations reduced at high frequency. Thus, the total quantum noise can be reduced. Such states can be generated using an optical cavity called a filter cavity. The second part of the work presented in this thesis consisted in defining the optical parameters of the filter cavity that will be installed on Virgo for O4. To do this, it was first necessary to study the sources of degradation of the squeezed states of the vacuum. This then allowed defining the length of the filtering cavity and the set of parameters of the mirrors that compose it. Finally, the implementation of this filter cavity within the Virgo infrastructure was studied. This has shown that the use of compressed states will effectively reduce quantum noise over the entire sensitivity spectrum of Virgo.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.