Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Multiplexing Superconducting Bolometer Arrays

R. A. Shafer, K. D. Irwin, Harvey Moseley, Johannes G. Staguhn, Dominic J. Benford, Ernie Buchanan, Umesh Patel, Erich N. Grossman, Gene C Hilton, Sae Woo Nam, C. D. Reintsema, Piet A. J. de Korte, Joern Beyer

Published Jan 1, 2002• 0 citations
OpenAlex

Related papers

Frequency domain multiplexing for bolometer arrays

Trevor M. Lanting, Hsiao-Mei Cho, John L. Clarke +6 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Dec 19, 2003•23 citations

Very-low-noise multiplexing with SQUIDs and SiGe HBTs for readout of large superconducting bolometer arrays

D. Prêle, G. Klisnick, G. Sou +4 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jun 5, 2007•5 citations

Multiplexed Readout of Superconducting Bolometers for Cosmological Observations

Trevor M. Lanting

•Jan 1, 2006•10 citations

SQUID Multiplexing Circuit for Readout of Superconducting Bolometric Arrays

James A. Chervenak, Erich N. Grossman, K. D. Irwin +5 more

APS•Mar 1, 1998•0 citations

Advanced Code-Division Multiplexers for Superconducting Detector Arrays

K. D. Irwin, Hsiao-Mei Cho, William Bertrand Doriese +7 more

arXiv:1110.1608•Journal of Low Temperature Physics•Feb 10, 2012•33 citations

Frequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements

M. Dobbs, Martin Lueker, K. A. Aird +44 more

A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.

arXiv:1112.4215•Review of Scientific Instruments•Jul 1, 2012•138 citations
A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.