ACTA PHOTONICA SINICA

Experimental Study of Radiometer Based on Spontaneous Parametric Down-conversion Calibration

胡友勃 You-bo HU, 高冬阳 Dong-yang GAO, 李健军 Jian-jun LI, 郑小兵 Xiao-bing ZHENG

Published Jan 1, 2020• 0 citations
Publisher
DOI
10.3788/gzxb20204906.0630001

Related papers

Calibration technology of infrared standard transfer radiometer based on stimulated parametric down-conversion

盛文阳 Sheng Wenyang, 夏茂鹏 Xia Maopeng, 李健军 Li Jianjun +2 more

Infrared and Laser Engineering•Jan 1, 2019•0 citations

Optical Radiometric Calibration Based on Parametric Down-Conversion Effect

李健军 Li Jianjun, 郑小兵 Zheng Xiaobing, 卢云君 Lu Yunjun +2 more

Acta Optica Sinica•Jan 1, 2008•0 citations

SI Traceable Solar Spectral Irradiance Measurement Based on a Quantum Benchmark: A Prototype Design

Xiaobing Zheng, Maopeng Xia, Wenchao Zhai +4 more

We propose a space benchmark sensor with onboard SI (Système International) traceability by means of quantum optical radiometry. Correlated photon pairs generated by spontaneous parametric down-conversion (SPDC) in nonlinear crystals are used to calibrate the absolute responsivity of a solar observing radiometer. The calibration is systematic, insensitive to degradation and independent of external radiometric standards. Solar spectral irradiance at 380–2500 nm is traceable to the photon rate and Planck’s constant with an expected uncertainty of about 0.35%. The principle of SPDC calibration and a prototype design of the solar radiometer are introduced. The uncertainty budget is analyzed in consideration of errors arising from calibration and observation modes.

Remote Sensing•May 4, 2020•9 citations

Analysis of the possibility of analog detectors calibration by exploiting stimulated parametric down conversion

G. Brida, Maria V. Chekhova, Marco Genovese +1 more

Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.

arXiv:0811.1120•Optics Express•Aug 5, 2008•17 citations

Parametric downconversion for radiometric applications

Alan L. Migdall, Raju U. Datla, Alexander V. Sergienko +2 more

•May 21, 1995•0 citations

On the measurement of photon flux in parametric down-conversion

G. Brida, Marco Genovese, Carlo Novero

arXiv:physics/9902027•The European Physical Journal D•Jan 1, 2000•8 citations
We propose a space benchmark sensor with onboard SI (Système International) traceability by means of quantum optical radiometry. Correlated photon pairs generated by spontaneous parametric down-conversion (SPDC) in nonlinear crystals are used to calibrate the absolute responsivity of a solar observing radiometer. The calibration is systematic, insensitive to degradation and independent of external radiometric standards. Solar spectral irradiance at 380–2500 nm is traceable to the photon rate and Planck’s constant with an expected uncertainty of about 0.35%. The principle of SPDC calibration and a prototype design of the solar radiometer are introduced. The uncertainty budget is analyzed in consideration of errors arising from calibration and observation modes.
Spontaneous parametric down conversion (SPDC) has been largely exploited as a tool for absolute calibration of photon-counting detectors, i.e detectors registering very small photon fluxes. In [J. Opt. Soc. Am. B 23, 2185 (2006)] we derived a method for absolute calibration of analog detectors using SPDC emission at higher photon fluxes, where the beam is seen as a continuum by the detector. Nevertheless intrinsic limitations appear when high-gain regime of SPDC is required to reach even larger photon fluxes. Here we show that stimulated parametric down conversion allow one to avoid this limitation, since stimulated photon fluxes are increased by the presence of the seed beam.