Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Coincidence detection of spatially correlated photon pairs with a monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini, David Stoppa, André Stefanov

Published Jan 1, 2016• 34 citations
OpenAlex

Abstract

We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.

Related papers

Coincidence detection of spatially correlated photon pairs with a monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.

arXiv:1609.03419•Optics Express•Dec 5, 2016•34 citations

Coincidence detection of spatially correlated photon pairs with a novel type of monolithic time-resolving detector array

Manuel Unternährer, Bänz Bessire, Leonardo Gasparini +2 more

Spatially entangled photon states are used in experiments addressing fundamental properties of quantum mechanics as well as practical applications [1]. Thereby, the use of these states demands for time-saving detection mechanisms, capable of measuring coincidences between spatially separated photons with high spatial and temporal resolution. In this work, we demonstrate coincidence detection of spatially correlated photon pairs by means of the SPADnet-I sensor [2], a fully digital 8×16 pixel single photon detector array in CMOS technology developed for medical applications. It enables per-pixel time stamping with 265 ps resolution combined with a high frame rate of 500 kfps [3]. Commonly used optically or electrically amplified CCD based systems exhibit magnitudes lower frame rates and temporal resolution.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•2 citations

Coincidence detection of spatially correlated photon pairs with a novel type of monolithic time-resolving detector array

Bänz Bessire, Manuel Unternährer, Leonardo Gasparini +2 more

We demonstrate a novel type of multi-pixel detector array which enables per-pixel time stamping with sub-nanosecond timing resolution and a high frame rate by measuring second-order correlation functions of transverse momentum entangled photons.

Quantum Information and Measurement (QIM)•Jan 1, 2017•2 citations

Counting of Hong-Ou-Mandel Bunched Optical Photons Using a Fast Pixel Camera

Andrei Nomerotski, Michael Keach, Paul Stankus +2 more

The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.

arXiv:2005.07982•Sensors•Jun 19, 2020•25 citations

Quantum correlations measured with multi-pixel detectors

Frauke Izdebski

use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-

•Aug 1, 2013•0 citations

Detection of non-classical space-time correlations with a novel type of single-photon camera

Felix Just, Mykhaylo Filipenko, Andrea Cavanna +9 more

During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed hybrid photon detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we apply this device to the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.

arXiv:1404.6946•Optics Express•Jul 11, 2014•11 citations
We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.
We demonstrate coincidence measurements of spatially entangled photons by means of a multi-pixel based detection array. The sensor, originally developed for positron emission tomography applications, is a fully digital 8×16 silicon photomultiplier array allowing not only photon counting but also per-pixel time stamping of the arrived photons with an effective resolution of 265 ps. Together with a frame rate of 500 kfps, this property exceeds the capabilities of conventional charge-coupled device cameras which have become of growing interest for the detection of transversely correlated photon pairs. The sensor is used to measure a second-order correlation function for various non-collinear configurations of entangled photons generated by spontaneous parametric down-conversion. The experimental results are compared to theory.
Spatially entangled photon states are used in experiments addressing fundamental properties of quantum mechanics as well as practical applications [1]. Thereby, the use of these states demands for time-saving detection mechanisms, capable of measuring coincidences between spatially separated photons with high spatial and temporal resolution. In this work, we demonstrate coincidence detection of spatially correlated photon pairs by means of the SPADnet-I sensor [2], a fully digital 8×16 pixel single photon detector array in CMOS technology developed for medical applications. It enables per-pixel time stamping with 265 ps resolution combined with a high frame rate of 500 kfps [3]. Commonly used optically or electrically amplified CCD based systems exhibit magnitudes lower frame rates and temporal resolution.
The uses of a silicon-pixel camera with very good time resolution (∼nanosecond) for detecting multiple, bunched optical photons is explored. We present characteristics of the camera and describe experiments proving its counting capabilities. We use a spontaneous parametric down-conversion source to generate correlated photon pairs, and exploit the Hong-Ou-Mandel (HOM) interference effect in a fiber-coupled beam splitter to bunch the pair onto the same output fiber. It is shown that the time and spatial resolution of the camera enables independent detection of two photons emerging simultaneously from a single spatial mode.
use of any of the information contained in it must acknowledge this thesis as the source of the quotation or information. This thesis investigates the measurement of spatial correlations of photon pairs gener-ated through spontaneous parametric down-conversion with single-photon sensitive multi-pixel detectors. A custom designed and fabricated 8×1 fibre array detector for time to position multi-plexing was characterised. This detector was then commissioned in an experiment measuring the spatial correlations of photon pairs in position, momentum and in-termediate bases. The fibre array measured eight positions simultaneously with one Single-Photon Avalanche Diode, which led to an eight-fold increase in the data ac-quisition rate compared to traditional experiments, where a single SPAD was scanned across the detection plane. To capture all of the emitted light, an electron-multiplying CCD (EMCCD) camera was used. The spatial correlations were measured for the first time in momentum and pos-