arXiv:1404.6946 · Optics Express

Detection of non-classical space-time correlations with a novel type of single-photon camera

Felix Just, Mykhaylo Filipenko, Andrea Cavanna, Thilo Michel, Thomas Gleixner, Michael Taheri, John V. Vallerga, Michael Campbell, Timo Tick, G. Anton, Maria V. Chekhova, Gerd Leuchs

Published Jul 11, 2014• 11 citations
arXivHTMLPDF

Abstract

During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed hybrid photon detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we apply this device to the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.

DOI
10.1364/oe.22.017561

Related papers

High-dimensional quantum correlation measurements with an adaptively gated hybrid single-photon camera

Sanjukta Kundu, Jerzy Szuniewicz, Grzegorz Firlik +2 more

Efficient measurement of high-dimensional quantum correlations, especially spatial ones, is essential for quantum technologies. We propose and demonstrate an adaptively gated hybrid intensified camera (HIC) that combines the information from a high spatial resolution sensor and a high temporal resolution detector, offering precise control over the number of photons detected within each frame. The HIC facilitates spatially resolved single-photon counting measurements. We study the measurement of momentum correlations of photon pairs generated in type-I spontaneous parametric downconversion with the HIC and demonstrate the possibility of time-tagging the registered photons. With a spatial resolution of multi-megapixels and nanosecond temporal resolution, this system allows for the realization of previously infeasible quantum optics experiments.

arXiv:2305.16245•Optica Quantum•May 23, 2024•4 citations

Quantum imaging with a photon counting camera

Osian Wolley, Thomas Gregory, Sebastian M. J. Beer +2 more

Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.

Scientific Reports•May 18, 2022•47 citations

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations

Characterisation of a single photon event camera for quantum imaging

Victor Vidyapin, Yingwen Zhang, Duncan G. England +1 more

We show a simple yet effective method that can be used to characterize the per pixel quantum efficiency and temporal resolution of a single photon event camera for quantum imaging applications. Utilizing photon pairs generated through spontaneous parametric down-conversion, the detection efficiency of each pixel, and the temporal resolution of the system, are extracted through coincidence measurements. We use this method to evaluate the TPX3CAM, with appended image intensifier, and measure an average efficiency of [Formula: see text]% and a temporal resolution of 7.3 ns. Furthermore, this technique reveals important error mechanisms that can occur in post-processing. We expect that this technique, and elements therein, will be useful to characterise other quantum imaging systems.

arXiv:2211.13788•Scientific Reports•Jan 18, 2023•33 citations

Real-time Processing of Correlated Photons for Quantum Imaging

Isaac Reichman, Gilad Pollack, Hadar Aharon +1 more

Quantum imaging leverages nonclassical correlations to reveal features that may vanish in conventional event integration [ 1, 2]. While single-photon detectors are well-established, quantum imaging demands complex data acquisition across many thousands of detectors, each generating rich metadata including triggering time, duration, and other properties. Consequently, effective data management, data wrangling, and correlation extraction become critical challenges. In this work, we investigate optimal handling of spatial correlations from a quantum-photonic source (spontaneous parametric down-conversion, SPDC) using an emerging single-photon event-based camera, the TPX3CAM (256×256 array, supported by an intensifier). Utilizing a femtosecond photon-pair source, we comprehensively analyse noise characteristics, including temporal dynamics and spatial distribution, to develop advanced spatio-temporal noise suppression strategies tailored to camera performance. Our primary objectives include real-time isolation and preprocessing of correlative data. Our analysis demonstrates the potential of these real-time correlation detection and noise reduction algorithms to expand quantum imaging capabilities across diverse scientific domains. Potential applications include high-resolution spectroscopy in biology, materials science, and advanced electron microscopy, where these techniques could enable identification of cascaded two-photon processes with atomic-scale precision. Figure 1 shows an excellent example of such a detection in real-space. The ring feature corresponds to the location of the correlated photon-pairs produced from the SPDC process. This is also apparent in figure 2, where we see a strong anti-correlation between the coordinates of the detected photons – corresponding to photon-pairs. <!-- named anchor --> Figure 1: Distribution of SPDC photons on TPX3CAM <!-- named anchor --> Figure 2: Spatial anti-correlation of x-coordinates

•Jan 1, 2025•0 citations

Heralded single-photon ghost imaging

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

•Dec 20, 2012•1 citation
During the last decades, multi-pixel detectors have been developed capable of registering single photons. The newly developed hybrid photon detector camera has a remarkable property that it has not only spatial but also temporal resolution. In this work, we apply this device to the detection of non-classical light from spontaneous parametric down-conversion and use two-photon correlations for the absolute calibration of its quantum efficiency.
Efficient measurement of high-dimensional quantum correlations, especially spatial ones, is essential for quantum technologies. We propose and demonstrate an adaptively gated hybrid intensified camera (HIC) that combines the information from a high spatial resolution sensor and a high temporal resolution detector, offering precise control over the number of photons detected within each frame. The HIC facilitates spatially resolved single-photon counting measurements. We study the measurement of momentum correlations of photon pairs generated in type-I spontaneous parametric downconversion with the HIC and demonstrate the possibility of time-tagging the registered photons. With a spatial resolution of multi-megapixels and nanosecond temporal resolution, this system allows for the realization of previously infeasible quantum optics experiments.
Classical light sources emit a randomly-timed stream of individual photons, the spatial distribution of which can be detected with a camera to form an image. Quantum light sources, based on parametric down conversion, emit photons as correlated photon-pairs. The spatial correlations between the photons enables imaging systems where the preferential selection of photon-pairs allows for enhancements in the noise performance over what is possible using classical light sources. However, until now the technical challenge of measuring, and correlating both photons has led to system complexity. Here we show that a camera capable of resolving the number of individual photons in each pixel of the detector array can be used to record an image formed from these photon-pair events and hence achieve a greater contrast than possible using a classical light source. We achieve an enhancement in the ratio of two-photon events compared to one-photon events using spatially correlated SPDC light compared to uncorrelated illumination by a LED. These results indicate the potential advantages of using photon counting cameras in quantum imaging schemes and these advantages will further increase as the technology is developed. Operating in photon sparse regimes such systems have potential applications in low-light microscopy and covert imaging.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
We show a simple yet effective method that can be used to characterize the per pixel quantum efficiency and temporal resolution of a single photon event camera for quantum imaging applications. Utilizing photon pairs generated through spontaneous parametric down-conversion, the detection efficiency of each pixel, and the temporal resolution of the system, are extracted through coincidence measurements. We use this method to evaluate the TPX3CAM, with appended image intensifier, and measure an average efficiency of [Formula: see text]% and a temporal resolution of 7.3 ns. Furthermore, this technique reveals important error mechanisms that can occur in post-processing. We expect that this technique, and elements therein, will be useful to characterise other quantum imaging systems.
Quantum imaging leverages nonclassical correlations to reveal features that may vanish in conventional event integration [ 1, 2]. While single-photon detectors are well-established, quantum imaging demands complex data acquisition across many thousands of detectors, each generating rich metadata including triggering time, duration, and other properties. Consequently, effective data management, data wrangling, and correlation extraction become critical challenges. In this work, we investigate optimal handling of spatial correlations from a quantum-photonic source (spontaneous parametric down-conversion, SPDC) using an emerging single-photon event-based camera, the TPX3CAM (256×256 array, supported by an intensifier). Utilizing a femtosecond photon-pair source, we comprehensively analyse noise characteristics, including temporal dynamics and spatial distribution, to develop advanced spatio-temporal noise suppression strategies tailored to camera performance. Our primary objectives include real-time isolation and preprocessing of correlative data. Our analysis demonstrates the potential of these real-time correlation detection and noise reduction algorithms to expand quantum imaging capabilities across diverse scientific domains. Potential applications include high-resolution spectroscopy in biology, materials science, and advanced electron microscopy, where these techniques could enable identification of cascaded two-photon processes with atomic-scale precision. Figure 1 shows an excellent example of such a detection in real-space. The ring feature corresponds to the location of the correlated photon-pairs produced from the SPDC process. This is also apparent in figure 2, where we see a strong anti-correlation between the coordinates of the detected photons – corresponding to photon-pairs. <!-- named anchor --> Figure 1: Distribution of SPDC photons on TPX3CAM <!-- named anchor --> Figure 2: Spatial anti-correlation of x-coordinates
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.