Squeezing the Local Oscillator Does Not Improve Signal-to-Noise Ratio in Heterodyne Laser Radar
Mark A. Rubin, Sumanth Kaushik
Abstract
The signal-to-noise ratio for heterodyne laser radar with a coherent target-return beam and a squeezed local-oscillator beam is lower than that obtained using a coherent local oscillator, regardless of the method employed to combine the beams at the detector. OCIS codes: 270.0270, 270.6570, 280.5600, 040.2840 Squeezed light holds promise for reducing noise in optical-detection applications below the level obtainable using coherent light such as that emitted by lasers. 1 However, squeezing is degraded by loss. 2 In laser radar applications, the loss in the target-return beam—the beam received by the radar system after reflection from a target—is severe. 3 Therefore squeezing is not useful in laser radar, at least not when applied to the target-return beam. This still leaves open the possibility that squeezed light could be profitably employed as the local oscillator in