Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chopped nonlinear magneto-optic rotation: A technique for precision measurements

Harish Ravishankar, Sapam Ranjita Chanu, Vasant Natarajan A

Published Jun 1, 2011• 3 citations
OpenAlex

Abstract

We have developed a technique for precise measurement of small magnetic fields using nonlinear magneto-optic rotation (NMOR). The technique relies on the resonant laser beam being chopped. During the on time, the atoms are optically pumped into an aligned ground state (Delta m=2 coherence). During the off time, they freely precess around the magnetic field at the Larmor frequency. If the on-off modulation frequency matches (twice) the Larmor precession frequency, the rotation is resonantly enhanced in every cycle, thereby making the process like a repeated Ramsey measurement of the Larmor frequency. We study chopped-NMOR in a paraffin-coated Cs vapor cell. The out-of-phase demodulated rotation shows a Lorentzian peak of linewidth 85 mu G, corresponding to a sensitivity of 0.15nG/root Hz. We discuss the potential of this technique for the measurement of an atomic electric-dipole moment. Copyright (C) EPLA, 2011

Related papers

Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields

Szymon Pustelny, Wojciech Gawlik, Simon Rochester +3 more

Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.

arXiv:physics/0606257•Physical Review A•Dec 29, 2006•56 citations

Nonlinear magneto-optical rotation with frequency-modulated light

Dmitry Budker, Derek F. Jackson Kimball, Valeriy V. Yashchuk +1 more

A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the submicrogauss level to above the earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms contained in a vapor cell with antirelaxation wall coating. Linearly polarized, frequency-modulated laser light is used for optical pumping and probing. If the time-dependent optical rotation is measured at the first harmonic of the modulation frequency, ultra-narrow (\ensuremath{\sim} a few hertz) resonances are observed at near-zero magnetic fields, and at fields where the Larmor frequency coincides with half the light modulation frequency. Upon optimization, the sensitivity of the technique is expected to exceed ${10}^{\ensuremath{-}11} G/\sqrt{\mathrm{Hz}}.$

arXiv:physics/0201025•Physical Review A•May 2, 2002•139 citations

Sensitive optical atomic magnetometer based on nonlinear magneto-optical rotation

Chris Hovde, Brian Patton, Eric Corsini +2 more

A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.

arXiv:1003.1531•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 23, 2010•6 citations

Magnetometric sensitivity optimization for nonlinear optical rotation with frequency-modulated light: Rubidium D2 line

Derek F. Jackson Kimball, Louis Jacome, Srikanth Guttikonda +2 more

Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).

arXiv:0906.3586•Journal of Applied Physics•Sep 15, 2009•32 citations

In situ measurement of light polarization with ellipticity-induced nonlinear magneto-optical rotation

Derek F. Jackson Kimball, Jordan Dudley, Yan Li +1 more

A precise, accurate, and relatively straightforward in situ method to measure and control the ellipticity of light resonantly interacting with an atomic vapor is described. The technique can be used to minimize vector light shifts. The method involves measurement of ellipticity-induced resonances in the magnetic-field dependence of nonlinear magneto-optical rotation of frequency-modulated light. The light propagation direction is orthogonal to the applied magnetic field $\mathbf{B}$ and the major axis of the light polarization ellipse is along $\mathbf{B}$. When the light modulation frequency matches the Larmor frequency, elliptically polarized light produces a precessing atomic spin orientation transverse to $\mathbf{B}$ via synchronous optical pumping. The precessing spin orientation causes optical rotation oscillating at the Larmor frequency by modulating the atomic vapor's circular birefringence. Based on this technique's precision, in situ nature (which avoids systematic errors arising from optical interfaces) and independent control of the most important systematic errors, it is shown that the accuracy of light ellipticity measurements achievable with this technique can exceed that of existing methods by orders of magnitude.

arXiv:1706.08149•Physical Review A•Sep 12, 2017•14 citations

All-optical vector atomic magnetometer

E. Zhivun, Brian Patton, Chris Hovde +1 more

We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.

Bulletin of the American Physical Society•Jun 5, 2014•21 citations
We have developed a technique for precise measurement of small magnetic fields using nonlinear magneto-optic rotation (NMOR). The technique relies on the resonant laser beam being chopped. During the on time, the atoms are optically pumped into an aligned ground state (Delta m=2 coherence). During the off time, they freely precess around the magnetic field at the Larmor frequency. If the on-off modulation frequency matches (twice) the Larmor precession frequency, the rotation is resonantly enhanced in every cycle, thereby making the process like a repeated Ramsey measurement of the Larmor frequency. We study chopped-NMOR in a paraffin-coated Cs vapor cell. The out-of-phase demodulated rotation shows a Lorentzian peak of linewidth 85 mu G, corresponding to a sensitivity of 0.15nG/root Hz. We discuss the potential of this technique for the measurement of an atomic electric-dipole moment. Copyright (C) EPLA, 2011
Larmor precession of laser-polarized atoms contained in antirelaxation-coated cells, detected via nonlinear magneto-optical rotation (NMOR), is a promising technique for a new generation of ultrasensitive atomic magnetometers. For magnetic fields directed along the light propagation direction, resonances in NMOR appear when linearly polarized light is frequency or amplitude modulated at twice the Larmor frequency. Because the frequency of these resonances depends on the magnitude but not the direction of the field, they are useful for scalar magnetometry. Additional NMOR resonances at the Larmor frequency appear when the magnetic field is tilted away from the light propagation direction in the plane defined by the light propagation and polarization vectors. These resonances, studied both experimentally and with a density matrix calculation in the present work, offer a convenient method of achieving additional information about a direction of the magnetic field.
A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the submicrogauss level to above the earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms contained in a vapor cell with antirelaxation wall coating. Linearly polarized, frequency-modulated laser light is used for optical pumping and probing. If the time-dependent optical rotation is measured at the first harmonic of the modulation frequency, ultra-narrow (\ensuremath{\sim} a few hertz) resonances are observed at near-zero magnetic fields, and at fields where the Larmor frequency coincides with half the light modulation frequency. Upon optimization, the sensitivity of the technique is expected to exceed ${10}^{\ensuremath{-}11} G/\sqrt{\mathrm{Hz}}.$
A self-oscillating magnetometer based on nonlinear magneto-optical rotation using amplitude-modulated pump light and unmodulated probe light (AM-NMOR) in 87Rb has been constructed and tested towards a goal of airborne detection of magnetic anomalies. In AM-NMOR, stroboscopic optical pumping via amplitude modulation of the pump beam creates alignment of the ground electronic state of the rubidium atoms. The Larmor precession causes an ac rotation of the polarization of a separate probe beam; the polarization rotation frequency provides a measure of the magnetic field. An anti-relaxation coating on the walls of the atomic vapor cell results in a long lifetime of 56 ms for the alignment, which enables precise measurement of the precession frequency. Light is delivered to the magnetometer by polarization-maintaining optical fibers. Tests of the sensitivity include directly measuring the beat frequency between the magnetometer and a commercial instrument and measurements of Earth's field under magnetically quiet conditions, indicating a sensitivity of at least 5 pT/νHz. Rotating the sensor indicates a heading error of less than 1 nT, limited in part by residual magnetism of the sensor.
Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).
A precise, accurate, and relatively straightforward in situ method to measure and control the ellipticity of light resonantly interacting with an atomic vapor is described. The technique can be used to minimize vector light shifts. The method involves measurement of ellipticity-induced resonances in the magnetic-field dependence of nonlinear magneto-optical rotation of frequency-modulated light. The light propagation direction is orthogonal to the applied magnetic field B\mathbf{B}B and the major axis of the light polarization ellipse is along B\mathbf{B}B. When the light modulation frequency matches the Larmor frequency, elliptically polarized light produces a precessing atomic spin orientation transverse to B\mathbf{B}B via synchronous optical pumping. The precessing spin orientation causes optical rotation oscillating at the Larmor frequency by modulating the atomic vapor's circular birefringence. Based on this technique's precision, in situ nature (which avoids systematic errors arising from optical interfaces) and independent control of the most important systematic errors, it is shown that the accuracy of light ellipticity measurements achievable with this technique can exceed that of existing methods by orders of magnitude.
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in a cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the AC Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of 50 fT/ √ Hz in measurement of the field magnitude and 0.5 mrad/ √ Hz in the field direction; elimination of technical noise would improve these sensitivities to 12 fT/ √ Hz and 5 μrad/ √ Hz, respectively. Applications for a precise all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.