Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning

D. T. C. Allcock, Luca Guidoni, T. P. Harty, Christopher J. Ballance, Andrew M. Steane, D. M. Lucas

Published Aug 16, 2016• 56 citations
OpenAlex

Abstract

Abstract. Laser-cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355nm. The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40Ca+ trapped ion as a function of its secular frequency ωz. A reduction of the electric-field noise spectral density by ∼ 50 % has been observed and a change in the frequency dependence also noticed. This is the first reported experiment where the “anomalous heating ” phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling. This technique may open the way to better control of the electrode surface quality in ion microtraps. ar

Related papers

Reduction of heating rate in a microfabricated ion trap by pulsed-laser cleaning

D T C Allcock, Luca Guidoni, T P Harty +4 more

Laser cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355 nm.The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40 Ca + trapped ion as a function of its secular frequency ω z .A reduction of the electric-field noise spectral density by ∼50% has been observed and a change in the frequency dependence also noticed.This is the first reported experiment where the 'anomalous heating' phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling.This technique may open up the way to better control of the electrode surface quality in ion microtraps.The recent success of quantum information experiments based on trapped ions [1] triggered research on micro-fabricated radio-frequency (Paul) traps, which are in principle able to fulfill the scalability requirement of a quantum computer [2,3].In such traps, a set of micro-fabricated conducting electrodes generates oscillating and static electric fields that trap laser-cooled ions in a harmonic potential well at a sub-millimeter distance d from the substrate [4,5].However, the presence of uncontrolled fluctuating electric fields affects the ions' external motion and induces an 'anomalous heating' that limits the achievable fidelity of multi-ion quantum gates that rely on the coherent control of this motion [6].Experimental observations concerning this phenomenon 4

arXiv:1110.1486•New Journal of Physics•Dec 16, 2011•63 citations

Reduction of trapped-ion anomalous heating byin situsurface plasma cleaning

Robert McConnell, Colin Bruzewicz, John Chiaverini +1 more

Anomalous motional heating is a major obstacle to scalable quantum information processing with trapped ions. Although the source of this heating is not yet understood, several previous studies suggest that noise due to surface contaminants is the limiting heating mechanism in some instances. We demonstrate an improvement by a factor of 4 in the room-temperature heating rate of a niobium surface electrode trap by in situ plasma cleaning of the trap surface. This surface treatment was performed with a simple homebuilt coil assembly and commercially available matching network and is considerably gentler than other treatments, such as ion milling or laser cleaning, that have previously been shown to improve ion heating rates. We do not see an improvement in the heating rate when the trap is operated at cryogenic temperatures, pointing to a role of thermally activated surface contaminants in motional heating whose activity may freeze out at low temperatures.

arXiv:1505.03844•Physical Review A•Aug 28, 2015•33 citations

Micro-fabricated stylus ion trap

Christian Lew Arrington, Kyle S. McKay, Ehren Donel Baca +14 more

An electroformed, three-dimensional stylus Paul trap was designed to confine a single atomic ion for use as a sensor to probe the electric-field noise of proximate surfaces. The trap was microfabricated with the UV-LIGA technique to reduce the distance of the ion from the surface of interest. We detail the fabrication process used to produce a 150 μm tall stylus trap with feature sizes of 40 μm. We confined single, laser-cooled, (25)Mg(+) ions with lifetimes greater than 2 h above the stylus trap in an ultra-high-vacuum environment. After cooling a motional mode of the ion at 4 MHz close to its ground state (<n> = 0.34 ± 0.07), the heating rate of the trap was measured with Raman sideband spectroscopy to be 387 ± 15 quanta/s at an ion height of 62 μm above the stylus electrodes.

Review of Scientific Instruments•Aug 1, 2013•25 citations

100-Fold Reduction of Electric-Field Noise in an Ion Trap Cleaned with In Situ Argon-Ion-Beam Bombardment

Dustin A. Hite, Yves Colombe, A. C. Wilson +8 more

Motional heating of trapped atomic ions is a major obstacle to their use as quantum bits in a scalable quantum computer. The detailed physical origin of this heating is not well understood, but experimental evidence suggests that it is caused by electric-field noise emanating from the surface of the trap electrodes. In this study, we have investigated the role of adsorbates on the electrodes by identifying contaminant overlayers, implementing an in situ argon-ion-beam cleaning treatment, and measuring ion heating rates before and after treating the trap electrodes' surfaces. We find a 100-fold reduction in heating rate after treatment. The experiments described here are sensitive to low levels of electric-field noise in the MHz frequency range. Therefore, this approach could become a useful tool in surface science that complements established techniques.

arXiv:1112.5419•Physical Review Letters•Sep 4, 2012•175 citations

Industrially microfabricated ion trap with 1 eV trap depth

Silke Auchter, Christopher J. Axline, Chiara Decaroli +12 more

Abstract Scaling trapped-ion quantum computing will require robust trapping of at least hundreds of ions over long periods, while increasing the complexity and functionality of the trap itself. Symmetric three-dimensional (3D) structures enable high trap depth, but microfabrication techniques are generally better suited to planar structures that produce less ideal conditions for trapping. We present an ion trap fabricated on stacked eight-inch wafers in a large-scale micro-electro-mechanical system microfabrication process that provides reproducible traps at a large volume. Electrodes are patterned on the surfaces of two opposing wafers bonded to a spacer, forming a 3D structure with 2.5 μm standard deviation in alignment across the stack. We implement a design achieving a trap depth of 1 eV for a 40Ca+ ion held at 200 μm from either electrode plane. We characterize traps, achieving measurement agreement with simulations to within ±5% for mode frequencies spanning 0.6–3.8 MHz, and evaluate stray electric field across multiple trapping sites. We measure motional heating rates over an extensive range of trap frequencies, and temperatures, observing 40 phonons/s at 1 MHz and 185 K. This fabrication method provides a highly scalable approach for producing a new generation of 3D ion traps.

arXiv:2202.08244•Quantum Science and Technology•May 17, 2022•23 citations

Fabrication and heating rate study of microscopic surface electrode ion traps

Nikos Daniilidis, Suresh Narayanan, Sönke Möller +7 more

We report heating rate measurements in a microfabricated gold-on-sapphire surface electrode ion trap with a trapping height of approximately 240 μm. Using the Doppler recooling method, we characterize the trap heating rates over an extended region of the trap. The noise spectral density of the trap falls in the range of noise spectra reported in ion traps at room temperature. We find that during the first months of operation, the heating rates increase by approximately one order of magnitude. The increase in heating rates is largest in the ion-loading region of the trap, providing a strong hint that surface contamination plays a major role for excessive heating rates. We discuss data found in the literature and the possible relation of anomalous heating to sources of noise and dissipation in other systems, namely impurity atoms adsorbed onto metal surfaces and amorphous dielectrics.

arXiv:1009.2834•New Journal of Physics•Jan 24, 2011•100 citations
Abstract. Laser-cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355nm. The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40Ca+ trapped ion as a function of its secular frequency ωz. A reduction of the electric-field noise spectral density by ∼ 50 % has been observed and a change in the frequency dependence also noticed. This is the first reported experiment where the “anomalous heating ” phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling. This technique may open the way to better control of the electrode surface quality in ion microtraps. ar
Laser cleaning of the electrodes in a planar micro-fabricated ion trap has been attempted using ns pulses from a tripled Nd:YAG laser at 355 nm.The effect of the laser pulses at several energy density levels has been tested by measuring the heating rate of a single 40 Ca + trapped ion as a function of its secular frequency ω z .A reduction of the electric-field noise spectral density by ∼50% has been observed and a change in the frequency dependence also noticed.This is the first reported experiment where the 'anomalous heating' phenomenon has been reduced by removing the source as opposed to reducing its thermal driving by cryogenic cooling.This technique may open up the way to better control of the electrode surface quality in ion microtraps.The recent success of quantum information experiments based on trapped ions [1] triggered research on micro-fabricated radio-frequency (Paul) traps, which are in principle able to fulfill the scalability requirement of a quantum computer [2,3].In such traps, a set of micro-fabricated conducting electrodes generates oscillating and static electric fields that trap laser-cooled ions in a harmonic potential well at a sub-millimeter distance d from the substrate [4,5].However, the presence of uncontrolled fluctuating electric fields affects the ions' external motion and induces an 'anomalous heating' that limits the achievable fidelity of multi-ion quantum gates that rely on the coherent control of this motion [6].Experimental observations concerning this phenomenon 4
Anomalous motional heating is a major obstacle to scalable quantum information processing with trapped ions. Although the source of this heating is not yet understood, several previous studies suggest that noise due to surface contaminants is the limiting heating mechanism in some instances. We demonstrate an improvement by a factor of 4 in the room-temperature heating rate of a niobium surface electrode trap by in situ plasma cleaning of the trap surface. This surface treatment was performed with a simple homebuilt coil assembly and commercially available matching network and is considerably gentler than other treatments, such as ion milling or laser cleaning, that have previously been shown to improve ion heating rates. We do not see an improvement in the heating rate when the trap is operated at cryogenic temperatures, pointing to a role of thermally activated surface contaminants in motional heating whose activity may freeze out at low temperatures.
An electroformed, three-dimensional stylus Paul trap was designed to confine a single atomic ion for use as a sensor to probe the electric-field noise of proximate surfaces. The trap was microfabricated with the UV-LIGA technique to reduce the distance of the ion from the surface of interest. We detail the fabrication process used to produce a 150 μm tall stylus trap with feature sizes of 40 μm. We confined single, laser-cooled, (25)Mg(+) ions with lifetimes greater than 2 h above the stylus trap in an ultra-high-vacuum environment. After cooling a motional mode of the ion at 4 MHz close to its ground state (<n> = 0.34 ± 0.07), the heating rate of the trap was measured with Raman sideband spectroscopy to be 387 ± 15 quanta/s at an ion height of 62 μm above the stylus electrodes.
Motional heating of trapped atomic ions is a major obstacle to their use as quantum bits in a scalable quantum computer. The detailed physical origin of this heating is not well understood, but experimental evidence suggests that it is caused by electric-field noise emanating from the surface of the trap electrodes. In this study, we have investigated the role of adsorbates on the electrodes by identifying contaminant overlayers, implementing an in situ argon-ion-beam cleaning treatment, and measuring ion heating rates before and after treating the trap electrodes' surfaces. We find a 100-fold reduction in heating rate after treatment. The experiments described here are sensitive to low levels of electric-field noise in the MHz frequency range. Therefore, this approach could become a useful tool in surface science that complements established techniques.
Abstract Scaling trapped-ion quantum computing will require robust trapping of at least hundreds of ions over long periods, while increasing the complexity and functionality of the trap itself. Symmetric three-dimensional (3D) structures enable high trap depth, but microfabrication techniques are generally better suited to planar structures that produce less ideal conditions for trapping. We present an ion trap fabricated on stacked eight-inch wafers in a large-scale micro-electro-mechanical system microfabrication process that provides reproducible traps at a large volume. Electrodes are patterned on the surfaces of two opposing wafers bonded to a spacer, forming a 3D structure with 2.5 μm standard deviation in alignment across the stack. We implement a design achieving a trap depth of 1 eV for a 40Ca+ ion held at 200 μm from either electrode plane. We characterize traps, achieving measurement agreement with simulations to within ±5% for mode frequencies spanning 0.6–3.8 MHz, and evaluate stray electric field across multiple trapping sites. We measure motional heating rates over an extensive range of trap frequencies, and temperatures, observing 40 phonons/s at 1 MHz and 185 K. This fabrication method provides a highly scalable approach for producing a new generation of 3D ion traps.
We report heating rate measurements in a microfabricated gold-on-sapphire surface electrode ion trap with a trapping height of approximately 240 μm. Using the Doppler recooling method, we characterize the trap heating rates over an extended region of the trap. The noise spectral density of the trap falls in the range of noise spectra reported in ion traps at room temperature. We find that during the first months of operation, the heating rates increase by approximately one order of magnitude. The increase in heating rates is largest in the ion-loading region of the trap, providing a strong hint that surface contamination plays a major role for excessive heating rates. We discuss data found in the literature and the possible relation of anomalous heating to sources of noise and dissipation in other systems, namely impurity atoms adsorbed onto metal surfaces and amorphous dielectrics.