We herein developed and demonstrated a Zeeman frequency modulation scheme for improving the signal-to-noise ratio of microwave electric field measurement using Rydberg atoms. The spectra of the electromagnetically induced transparency (EIT) and Autler-Townes splitting of Rydberg atoms is frequency modulated by an alternating current magnetic field. The signal-to-noise ratio of the corresponding dispersive error signal is enhanced more than 10 times than that of the original spectrum. Furthermore, we show that the slope of the dispersive error signal near the resonance of the Rydberg EIT can be used to characterize the weak microwave electric field amplitudes. The more intuitive and simpler structure compared with other existing frequency modulation technologies greatly reduces the difficulties of experiments and experimental data analysis.
We herein developed and demonstrated a Zeeman frequency modulation scheme for improving the signal-to-noise ratio of microwave electric field measurement using Rydberg atoms. The spectra of the electromagnetically induced transparency (EIT) and Autler-Townes splitting of Rydberg atoms is frequency modulated by an alternating current magnetic field. The signal-to-noise ratio of the corresponding dispersive error signal is enhanced more than 10 times than that of the original spectrum. Furthermore, we show that the slope of the dispersive error signal near the resonance of the Rydberg EIT can be used to characterize the weak microwave electric field amplitudes. The more intuitive and simpler structure compared with other existing frequency modulation technologies greatly reduces the difficulties of experiments and experimental data analysis.
We have theoretically and experimentally studied the dispersive signal of the Rydberg atomic electromagnetically-induced transparency (EIT) Autler–Townes (AT) splitting spectra obtained using amplitude modulation of the microwave (MW) electric field. In addition to the two zero-crossing points interval Δf zeros, the dispersion signal has two positive maxima with an interval defined as the shoulder interval Δf sho, which is theoretically expected to be used to measure a much weaker MW electric field. The relationship of the MW field strength E MW and Δf sho is experimentally studied at the MW frequencies of 31.6 GHz and 9.2 GHz respectively. The results show that Δf sho can be used to characterize the much weaker E MW than that of Δf zeros and the traditional EIT–AT splitting interval Δf m; the minimum E MW measured by Δf sho is about 30 times smaller than that by Δf m. As an example, the minimum E MW at 9.2 GHz that can be characterized by Δf sho is 0.056 mV/cm, which is the minimum value characterized by the frequency interval using a vapor cell without adding any auxiliary fields. The proposed method can improve the weak limit and sensitivity of E MW measured by the spectral frequency interval, which is important in the direct measurement of weak E MW.
The microwave (MW) field can be measured by the Autler–Townes (AT) splitting of the electromagnetically induced transparency (EIT) spectrum in the Rydberg atomic system; however, the EIT-AT splitting method fails in weak MW fields. We used the amplitude modulation of the MW field to resolve the EIT-AT splitting in weak MW fields. The EIT-AT splitting interval can be directly obtained, and the minimum detectable MW strength is improved by six times compared with the traditional EIT-AT splitting method. The proposed method is more intuitive and convenient for measuring the strength of weak MW fields in practical applications.
The microwave electric field intensity is precisely measured by the Autler–Townes splitting of electromagnetically induced transparency spectrum in a 5S1/2−5P3/2−57D5/2−58P3/2 four-level ladder-type 85Rb atomic system. A robust multi-carrier modulation scheme is employed to improve the spectral signal-to-noise ratio, which determines the optical readout of Rydberg atom-based microwave electrometry. As a result, a factor of 2 measurement sensitivity improvement is clearly achieved compared with the on resonant Autler–Townes splitting case credit to the advantage of matched filtering. This research paves the way for building a high sensitivity, portable sensor and offers a platform for achieving compact and sensitive receiver.
We provide the simultaneous traceable measurements of microwave electric fields at two different frequencies by the electromagnetically induced transparency (EIT) and Autler–Townes (AT) splitting. A static magnetic field working together with a linearly polarized probe and coupling light prepares Rydberg atoms in Zeeman sublevels with maximal |mJ| in an atomic vapor cell. Using the EIT-AT splitting of these two maximal |mJ| states, the microwave electric fields at two different frequencies are simultaneously measured, in which their frequency difference can be adjustable within the linear range of magnetic field-induced level shifts. The proposed method provides a promising prospect for calibrating multiple microwave frequencies simultaneously in the future.
Atoms form the basis of precise measurement for many quantities (time, acceleration, rotation, magnetic field, etc.). Measurements of microwave frequency electric fields by traditional methods (i.e. engineered antennas) have limited sensitivity and can be difficult to calibrate properly. Highly-excited (Rydberg) neutral atoms have very large electric-dipole moments and many dipole allowed transitions in the range of 1 - 500 GHz. It is possible to sensitively probe the electric field in this range using the combination of two quantum interference phenomena: electromagnetically induced transparency and the Autler-Townes effect. This technique allows for very sensitive field amplitude, polarization, and sub-wavelength imaging measurements. These quantities can be extracted by measuring properties of a probe laser beam as it passes through a warm rubidium vapor cell. Thus far, Rydberg microwave electrometry has relied upon the absorption of the probe laser. We report on our use of polarization rotation, which corresponds to the real part of the susceptibility, for measuring the properties of microwave frequency electric fields. Our simulations show that when a magnetic field is present and directed along the optical propagation direction a polarization rotation signal exists and can be used for microwave electrometry. One central advantage in using the polarization rotation signal rather than the absorption signal is that common mode laser noise is naturally eliminated leading to a potentially dramatic increase in signal-to-noise ratio.
ObjectiveThe microwave electric field intensity was measured using Electromagnetically induced transparency (EIT) and Autler-Townes (AT) spectrum based on Rydberg atoms. The typical EIT spectral line width is about 10 MHz, and the traceability process requires that the rabi frequency of microwave coupling with atoms exceeds the EIT linewidth to obtain the EIT-AT splitting spectrum with high signal-to-noise ratio. A small rabi frequency will lead to a large traceability error, which posing challenges for weak-field microwave metrology under weak field conditions.MethodsThe typical optical parametric oscillation process can realize the frequency conversion of weak optical signals. It can also be used to regulate the coupling of Rydberg atoms with microwave fields. Rabi resonance is a typical parametric process. Microwave-atom coupling is controlled by phase modulation of the field to be measured, and Rabi frequency measurement can be achieved under relatively weak conditions. This work investigates the parametric amplification effect of Rydberg atom-microwave coupling through tuning the coupling characteristics of microwave and Rydberg atom by parametric process.Results and DiscussionsThe Rabi resonance spectrum introduces parametric tuning through microwave field phase modulation to simulate the Rabi resonance effect of microwave-Rydberg atomic coupling. For the determined microwave-atomic coupling, the strength of the spectrum signal related to the Rabi frequency depends on the microwave-atomic frequency detuning. Under the conditions of the determined Rabi frequency and modulation frequency, there is no P1 Rabi resonance. The P2 Rabi resonance reaches its maximum. On this basis, the relationship between P2 and Rabi frequency and phase modulation frequency is calculated. Further, the spectrum measurement scheme of Rabi resonance is optimized for characterizing Rydberg atomic spectral responses of the parametric process under the condition of weak electric field. The Rabi resonance usually requires a modulation frequency greater than the EIT line width, and its measurement limit also depends on the EIT line width, the EIT line width is 6 MHz and 0.5 MHz, and the relative enhancement factor of the Rabi resonance is 119 times and 10 times, respectively. If the spectral line width is lower than MHz, as the spectral line width approaches the EIT line width limit, the parametric process gain decreases, and the relative resonance enhancement ratio also decreases. This technique converts the spectrum splitting measurement of Rabi frequency into spectral intensity measurement, and the obtained high SNR spectra can realize the measurement of microwave electric field intensity under the condition of weak field.ConclusionsIn this paper, the measurement principle of microwave electric field of Rydberg atom is briefly discussed, and the coupling dynamics of microwave field-Rydberg atom is simulated by quantum theory. Building upon this framework, we investigate Rabi resonance effect of Rydberg atoms is studied by introducing controllable parameters through microwave field phase modulation. Based on EIT spectrum and Rabi resonance spectrum modeling, the Rydberg atomic spectral characteristics of parametric processes under weak electric field are simulated. Finally, we discuss the Rabi frequency measurement of Rydberg atom based on Rabi resonance spectroscopy, enabling high-precision weak-field microwave metrology through the enhancement effect of Rabi resonance parameter.