Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cryogenics

A 10 mK hermetic cell for eliminating parasitic heating in cryogen-free dilution refrigerators

D. Schmoranzer, Sumit Kumar, S. Triqueneaux, Xiao Liu, Thomas Metcalf, Glenn G. Jernigan, Eddy Collin, Andrew D. Fefferman

Published Aug 7, 2020• 0 citations
Publisher
DOI
10.1016/j.cryogenics.2020.103162

Related papers

Modular and integrable cryogen-free dilution refrigerator

Anonymous, Pei Liu, De Ming Wang +6 more

Physical Review Applied•Aug 31, 2026•0 citations

On-Chip Demagnetisation Cooling on a Cryogen-Free Dilution Refrigerator

Alexander Thomas Jones

Springer theses•Jan 1, 2020•0 citations

On-Chip Demagnetisation Cooling on a Cryogen-Filled Dilution Refrigerator

Alexander Thomas Jones

Springer theses•Jan 1, 2020•0 citations

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

Sean A. Myers, Hongxi Li, G. A. Csáthy

arXiv:2110.03788•Cryogenics•Sep 29, 2021•8 citations

Magnetic cooling of electrons to 311 μK in a cryo-free dilution refrigerator

Mohammad Samani, C. P. Scheller, Nikolai Yurttagül +7 more

Bulletin of the American Physical Society•Mar 18, 2021•0 citations

A 10 mK hermetic cell for eliminating parasitic heating in cryogen-free dilution refrigerators

D. Schmoranzer, Sumit Kumar, S. Triqueneaux +5 more

Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.

arXiv:1911.03160•Nov 8, 2019•0 citations
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.