Radiotekhnika i Elektronika

Complex parametric optimization of a passive quantum frequency standard according to accuracy characteristics

V. S. Zholnerov

Published Nov 1, 1991• 0 citations
OpenAlex

Related papers

On optimizing the parameters of the static automatic frequency control system of a passive quantum frequency standard in terms of the accuracy characteristics

V. S. Zholnerov, V. V. Kornienko

RaEl•Jan 1, 1976•0 citations

Problem of choosing optimal values of phase-AFC parameters in quantum frequency standards

Boris Ivanovich Makarenko, Alexandr Sergeevich Sultanov, Michael A. Ivanov +2 more

RatK•Jan 1, 1978•0 citations

Metrological characteristics of quantum frequency-standards in the time domain

N. V. Goldovskaya, E. K. Bibikov, I. I. Dudich +1 more

Measurement Techniques•Aug 1, 1991•0 citations

Statement of the problem of assessing instability of passive quantum frequency standards in the presence of an error from the interaction

Олексій Нарєжній, Tetiana Grinenko, І.Д. Горбенко

Construction of modern measuring complexes of the coordinate-time support system of Ukraine is impossible without improving mathematical models of quantum standards of frequency (QSF) used in group standards. This work is devoted to the analysis of methods for the stable solution of direct and inverse problems (methods for solving ill-posed problems) in models of the interaction of passive QSF in the process of their comparisons. The priority task is to use these methods for the numerical solution of problems in the design of group QSF and parallel quantum generators of random numbers. Methods for solving such problems are in demand, since they make it possible to create mathematical models of group QSF interaction. These models will enable the design of efficient parallel quantum random number generation devices for high-tech areas of cybersecurity. Varieties of methods such as the method of least squares or the method of the Moore-Penrose pseudo-inverse matrix are used, as a rule when evaluating the metrological parameters of QSF.Robust methods of regularization or filtering, for example, the Kalman or Wiener filter method, are used in the algorithms of group standards, due to the instability of the solution.However, these methods do not work in the presence of an error from the interaction of QSF in the process of their functioning in a group standard or in comparisons. The aim of this work is to analyze and substantiate the formulation of the problem of assessing the potential accuracy characteristics of passive QSF in the presence of an error from the interaction. Regularization parameters when determining the state vector of the group standard are found using signals transmitted by global navigation satellite systems such as GPS\GLONASS in the local differential correction mode.

Radiotekhnika•Sep 24, 2021•0 citations

Design of A Downsized Spectrum Lamp

Sheng Rong-wu

The downsized spectrum lamp is one of the key points of the miniature passive Rubidium Frequency Standards(RFS).As a complex compound,the lamp is divided into four aspects which include mechanical structure,thermal distribution,electromagnetic radiation and exciting circuit scheme.According to the result of compute simulation and parameters optimization a downsized lamp is designed and result in good performance as followed:volume14mL,lamp temperature115 ℃,exciting current80 mA,light drift1·10-4/day,light sensitivity1·10-3/℃.This downsized spectrum lamp have been used successfully in the miniature RFS.

Yuhang jice jishu•Jan 1, 2008•1 citation

Measurements of the instability characteristics of quantum frequency standards

V. A. Dubkov, E. V. Kulagin, A. I. Pikhtelev +1 more

Measurement Techniques•Feb 1, 1984•0 citations
Construction of modern measuring complexes of the coordinate-time support system of Ukraine is impossible without improving mathematical models of quantum standards of frequency (QSF) used in group standards. This work is devoted to the analysis of methods for the stable solution of direct and inverse problems (methods for solving ill-posed problems) in models of the interaction of passive QSF in the process of their comparisons. The priority task is to use these methods for the numerical solution of problems in the design of group QSF and parallel quantum generators of random numbers. Methods for solving such problems are in demand, since they make it possible to create mathematical models of group QSF interaction. These models will enable the design of efficient parallel quantum random number generation devices for high-tech areas of cybersecurity. Varieties of methods such as the method of least squares or the method of the Moore-Penrose pseudo-inverse matrix are used, as a rule when evaluating the metrological parameters of QSF.Robust methods of regularization or filtering, for example, the Kalman or Wiener filter method, are used in the algorithms of group standards, due to the instability of the solution.However, these methods do not work in the presence of an error from the interaction of QSF in the process of their functioning in a group standard or in comparisons. The aim of this work is to analyze and substantiate the formulation of the problem of assessing the potential accuracy characteristics of passive QSF in the presence of an error from the interaction. Regularization parameters when determining the state vector of the group standard are found using signals transmitted by global navigation satellite systems such as GPS\GLONASS in the local differential correction mode.
The downsized spectrum lamp is one of the key points of the miniature passive Rubidium Frequency Standards(RFS).As a complex compound,the lamp is divided into four aspects which include mechanical structure,thermal distribution,electromagnetic radiation and exciting circuit scheme.According to the result of compute simulation and parameters optimization a downsized lamp is designed and result in good performance as followed:volume14mL,lamp temperature115 ℃,exciting current80 mA,light drift1·10-4/day,light sensitivity1·10-3/℃.This downsized spectrum lamp have been used successfully in the miniature RFS.